Ressa Reneth Sarreal

Ms. Ressa Reneth Sarreal

Georgia Institute of Technology
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016
Verified
Conference Paper
Closed access
PDF file
GMGabriela Marcu
Gabriela Marcu
NDNadia Dowshen
Nadia Dowshen
SSShuvadittya Saha
Shuvadittya Saha
RSRessa Reneth Sarreal
Ressa Reneth Sarreal
NANazanin Andalibi
Nazanin Andalibi

26 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RSRessa Reneth Sarreal
Ressa Reneth Sarreal
PBPamela Bhatti
Pamela Bhatti
According to the National Institute of Deafness and other Communication Disorders 2012 report, the number of cochlear implant (CI) users is steadily increasing from 324,000 CI users worldwide. The cochlea, located in the inner ear, is a snail-like structure that exhibits a tonotopic geometry where acoustic waves are filtered spatially according to frequency. Throughout the cochlea, there exist hair cells that transduce sensed acoustic waves into an electrical signal that is carried by the auditory nerve to ultimately reach the auditory cortex of the brain. A cochlear implant bridges the gap if non-functional hair cells are present. Conventional CIs directly inject an electrical current into surrounding tissue via an implanted electrode array and exploit the frequency-to-place mapping of the cochlea. However, the current is dispersed in perilymph, a conductive bodily fluid within the cochlea, causing a spread of excitation. Magnetic fields are more impervious to the effects of the cochlear environment due to the material properties of perilymph and surrounding tissue, demonstrating potential to improve precision. As an alternative to conventional CI electrodes, the development and miniaturization of microcoils intended for micromagnetic stimulation of intracochlear neural elements is described. As a step toward realizing a microcoil array sized for cochlear implantation, human-sized coils were prototyped via aerosol jet printing. The batch reproducible aerosol jet printed microcoils have a diameter of 1800 μm, trace width and trace spacing of 112.5 μm, 12 μm thickness, and inductance values of approximately 15.5 nH. Modelling results indicate that the coils have a combined depolarization–hyperpolarization region that spans 1.5 mm and produce a more restrictive spread of activation when compared with conventional CI.

29 July 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
RSRessa Reneth Sarreal
Ressa Reneth Sarreal
DBDavid T. Blake
David T. Blake
PBPamela Bhatti
Pamela Bhatti
To stimulate the auditory nerve, cochlear implants directly inject electrical current into surrounding tissue via an implanted electrode array. While many cochlear implant users achieve strong speech perception scores, there remains significant variability. Since cochlear implant electrode arrays are surrounded by a conductive fluid, perilymph, a spread of excitation occurs. The functionality of the cochlea is spatially dependent, and a wider area of excitation negatively affects the hearing of the user. Importantly, magnetic fields are unaffected by the material properties of biological components. To utilize the electromagnetic properties of the human ear, a microcoil array was developed. The microcoils are 4-turn solenoids with a 250- $\mu \text{m}$ turn radius and a 31.75- $\mu \text{m}$ wire radius, coated with Parylene-C. The efficient design was implemented to accelerate testing. The obtained results describe stimulation capabilities. Functionality was validated using a frequency response analyzer to measure how the generated electromagnetic power radiates in space. 99.8% power loss was observed over a 100- $\mu \text{m}$ separation between a pair of identical microcoils. Obtained through finite-element modeling, the microcoils can be driven by a 60 mA, 5 kHz, sinusoidal input for 10 minutes before predicted inflammation. Rattay’s activating function was calculated to evaluate the magnetic stimulation effect of external fields on target neurons. Combined with the frequency response analysis, magnitude and spatial effects of the generated potential is established. As a result, each microcoil requires a 400- $\mu \text{m}$ -wide area for each independent stimulation channel, which is 84% narrower than a commercial cochlear array channel, thereby suggesting greater spatial selectivity.

1 April 2017
Verified
Conference Paper
Closed access
TKTanmay Kulkarni
Tanmay Kulkarni
AHAlex Holtschneider
Alex Holtschneider
RSRessa Reneth Sarreal
Ressa Reneth Sarreal
GSGymama Slaughter
Gymama Slaughter
Herein a system capable of simultaneously sensing glucose and harvesting sufficient energy to power a digital device is presented. This system is powered by an enzymatic glucose biofuel cell consisting of pyroloquinoline quinone glucose dehydrogenase (PQQ-GDH) modified bioanode and bilirubin oxidase modified biocathode. The electrical parameters from a single biofuel cell were amplified to 1.4 V using a charge pump circuit consisting of a capacitive element that senses glucose. Further a steady output DC supply of 3.2 V was obtained by interfacing a step up DC-DC converter circuit to the charge pump circuit. Such a system simultaneously senses glucose and harvests energy in various glucose concentrations operating under physiological conditions (37 °C and pH 7.4). The novel system shows a promising future for healthcare systems industry.

1 April 2018
Verified
Conference Paper
Closed access
RSRessa Reneth Sarreal
Ressa Reneth Sarreal
GSGymama Slaughter
Gymama Slaughter
We report a sensitive amperometric dual glucose and lactate biosensor based on pyroloquinoline quinone glucose dehydrogenase (PQQ-GDH) and a lactate dehydrogenase (LDH) for the detection of glucose and lactate, respectively. The electrochemical sensing platform comprise multi-walled carbon nanotubes (MWCNTs) for the immobilization of the PQQ-GDH and LDH at the respective working electrodes. Platinum and Ag/AgCl counter and reference electrodes were integrated to construct a three-electrode system. The lactate biosensor component exhibited a linear response towards lactate over a concentration range of 1 to 10 mM lactate (r 2 = 0.998) and exhibit a sensitivity of 2.9 μA mM -1 cm -2 , whereas the glucose biosensor exhibited a linear response range of 1 to 10 mM glucose (r 2 = 0.990) and a sensitivity of 345.7 μA mM -1 cm -2 . These results show that the dual glucose and lactate biosensor possess important potential for application in clinical analysis and sports medicine.