Nathan Gluck

Dr. Nathan Gluck

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2019 in Hereditary Cancer in Clinical Practice
Verified
Journal Article
Open access
PDF file
TSToni Seppälä
Toni Seppälä
AAAysel Ahadova
Aysel Ahadova
MDMev Dominguez-Valentin
Mev Dominguez-Valentin
FMFinlay Macrae
Finlay Macrae
D. Gareth EvansD. Gareth Evans
D. Gareth Evans
PMPål Moller
Pål Moller
Recent epidemiological evidence shows that colorectal cancer (CRC) continues to occur in carriers of pathogenic mismatch repair (path_MMR) variants despite frequent colonoscopy surveillance in expert centres. This observation conflicts with the paradigm that removal of all visible polyps should prevent the vast majority of CRC in path_MMR carriers, provided the screening interval is sufficiently short and colonoscopic practice is optimal. To inform the debate, we examined, in the Prospective Lynch Syndrome Database (PLSD), whether the time since last colonoscopy was associated with the pathological stage at which CRC was diagnosed during prospective surveillance. Path_MMR carriers were recruited for prospective surveillance by colonoscopy. Only variants scored by the InSiGHT Variant Interpretation Committee as class 4 and 5 (clinically actionable) were included. CRCs detected at the first planned colonoscopy, or within one year of this, were excluded as prevalent cancers. Stage at diagnosis and interval between last prospective surveillance colonoscopy and diagnosis were available for 209 patients with 218 CRCs, including 162 path_MLH1, 45 path_MSH2, 10 path_MSH6 and 1 path_PMS2 carriers. The numbers of cancers detected within < 1.5, 1.5–2.5, 2.5–3.5 and at > 3.5 years since last colonoscopy were 36, 93, 56 and 33, respectively. Among these, 16.7, 19.4, 9.9 and 15.1% were stage III–IV, respectively (p = 0.34). The cancers detected more than 2.5 years after the last colonoscopy were not more advanced than those diagnosed earlier (p = 0.14). The CRC stage and interval since last colonoscopy were not correlated, which is in conflict with the accelerated adenoma-carcinoma paradigm. We have previously reported that more frequent colonoscopy is not associated with lower incidence of CRC in path_MMR carriers as was expected. In contrast, point estimates showed a higher incidence with shorter intervals between examinations, a situation that may parallel to over-diagnosis in breast cancer screening. Our findings raise the possibility that some CRCs in path_MMR carriers may spontaneously disappear: the host immune response may not only remove CRC precursor lesions in path_MMR carriers, but may remove infiltrating cancers as well. If confirmed, our suggested interpretation will have a bearing on surveillance policy for path_MMR carriers.

1 May 2016 in Gastrointestinal Endoscopy
Verified
Journal Article
Open access
NGNathan Gluck
Nathan Gluck
AMAlaa Melhem
Alaa Melhem
ZHZamir Halpern
Zamir Halpern
KMKlaus Mergener
Klaus Mergener
ESErwin Santo
Erwin Santo
The self-propelled disposable colonoscope (SPDC) with a 360° view is designed to enhance visualization, minimize risks of perforation and infection transmission, and shorten operator training time associated with conventional colonoscopy (CC). We evaluated SPDC efficacy for cecal intubation and safety. Prospective patients presenting for colorectal cancer screening underwent SPDC immediately followed by CC. Initial patients necessary for SPDC operators to achieve proficiency comprised the training cohort. Subsequent enrolled patients comprised the study cohort. SPDC colonoscopy was performed up to the cecum, where anatomic landmarks were photographed and mucosal suction marks were placed. During SPDC withdrawal, polyps were recorded and similarly marked. On the second pass (by using CC), any potential mucosal damage and suction marks from the SPDC as well as polyps were recorded. Main endpoints included SPDC cecal intubation rates, confirmed by anatomic landmarks and residual marks seen on subsequent CC, and frequency and severity of adverse events and mucosal damage with SPDC. The secondary endpoint was subjective procedure proficiency, evaluated by the operator based on the training cohort. The tertiary endpoint was documenting pathologies visualized with SPDC. Fifty-six of 58 enrolled subjects completed the study. Proficiency with SPDC was attained after 8 to 10 procedures. Cecal intubation was successful in 98.2% (55/56 subjects; 95% confidence interval [CI], 90.4%-99.9%), including 100% (95% CI, 90.7%-100%) of the study cohort and 94.4% (95% CI, 72.7%-99.9%) of the training cohort. No mucosal damage or adverse events were reported. SPDC detected 87.5% of polyps seen in tandem CC, including all polyps larger than 5 mm. SPDC was highly successful, simple to use, and safe in achieving complete colonoscopy (cecal intubation). ( 0692-12-TLV.).

2 June 2021 in United European Gastroenterology Journal
Verified
Journal Article
Open access
PDF file
NANaim Abu-Freha
Naim Abu-Freha
LKLior H. Katz
Lior H. Katz
RKRevital Kariv
Revital Kariv
EVElez Vainer
Elez Vainer
ILIdo Laish
Ido Laish
ZLZohar Levi
Zohar Levi
Background: Recently, three updated guidelines for post‐polypectomy colonoscopy surveillance (PPCS) have been published. These guidelines are based on a comprehensive summary of the literature, while some recommendations are similar, different surveillance intervals are recommended after detection of specific types of polyps.Aim: In this review, we aimed to compare and contrast these recommendations.Methods: The updated guidelines for PPCS were reviewed and the recommendations were compared.Results: For patients with 1–4 adenomas <10 mm with low‐grade dysplasia, irrespective of villous components, or 1–4 serrated polyps <10 mm without dysplasia, the European Society of Gastrointestinal Endoscopy (ESGE) and British Society of Gastroenterology (BSG), the Association of Coloproctology of Great Britain and Ireland (ACPGBI) and Public Health England (PHE) (BSG/ACPGBI/PHE) guidelines do not recommend colonoscopic surveillance and instead recommend that the participate in routine CRC screening program (typically based on the fecal immunochemical test), while the USMSTF recommends surveillance colonoscopies 7–10 years after diagnosis of 1–2 tubular adenomas <10 mm and 3–5 years for 3–4 tubular adenomas of the same size. The USMSTF define adenomas with tubulovillous or villous histology as high‐risk adenomas; thus, surveillance colonoscopy is recommended after 3 years. However, the ESGE and BSG do not consider such histology as a criterion for repeating colonoscopy at this short interval. For patients with 1–2 sessile serrated polyps (SSPs) <10 mm and those with 3–4 SSPs <10 mm, the USMSTF recommends surveillance colonosocopy after 5–10 and 3–5 years, respectively.

1 December 2015 in Gut
Verified
Journal Article
Open access
PDF file
NGNathan Gluck
Nathan Gluck
BSBeni Shpak
Beni Shpak
RBRita Brun
Rita Brun
TRThomas Rösch
Thomas Rösch
NANadir Arber
Nadir Arber
MMMenachem Moshkowitz
Menachem Moshkowitz
The demand for bowel cleansing hampers participation in screening colonoscopy, while poor preparation impairs adenoma detection. A novel prepless X-ray imaging capsule for colon screening is presented; the capsule emits low dose X-rays, which are scattered by ingested contrast agent mixed with colon contents, and sensed by detectors in the capsule to generate high-resolution three-dimensional (3D) imagery of the colon without bowel cleansing. Following preliminary studies with implanted polyps in synthetic colon phantoms, bovine cadaver and live swine, and human experiments with dummy capsules (n=75), 49 patients swallowed the capsule with natural excretion in 48 after 73.2±45.4 h. Pedunculated and sessile polyps were clearly seen and validated by subsequent colonoscopy. Total radiation exposure was ultra low (0.03±0.007 mSv).

Verified
Journal Article
Open access
PDF file
MDMev Dominguez-Valentin
Mev Dominguez-Valentin
JPJohn-Paul Plazzer
John-Paul Plazzer
JSJulian Sampson
Julian Sampson
CEChristoph Engel
Christoph Engel
SAStefan Aretz
Stefan Aretz
PMPål Moller
Pål Moller
Background. Lynch syndrome is the most common genetic predisposition for hereditary cancer. Carriers of pathogenic changes in mismatch repair (MMR) genes have an increased risk of developing colorectal (CRC), endometrial, ovarian, urinary tract, prostate, and other cancers, depending on which gene is malfunctioning. In Lynch syndrome, differences in cancer incidence (penetrance) according to the gene involved have led to the stratification of cancer surveillance. By contrast, any differences in penetrance determined by the type of pathogenic variant remain unknown. Objective. To determine cumulative incidences of cancer in carriers of truncating and missense or aberrant splicing pathogenic variants of the MLH1 and MSH2 genes. Methods. Carriers of pathogenic variants of MLH1 (path_MLH1) and MSH2 (path_MSH2) genes filed in the Prospective Lynch Syndrome Database (PLSD) were categorized as truncating or missense/aberrant splicing according to the InSiGHT criteria for pathogenicity. Results. Among 5199 carriers, 1045 had missense or aberrant splicing variants, and 3930 had truncating variants. Prospective observation years for the two groups were 8205 and 34,141 years, respectively, after which there were no significant differences in incidences for cancer overall or for colorectal cancer or endometrial cancers separately. Conclusion. Truncating and missense or aberrant splicing pathogenic variants were associated with similar average cumulative incidences of cancer in carriers of path MLH1 and path_MSH2.

14 November 2018 in Frontiers in Immunology
Verified
Journal Article
Open access
PDF file
OMOdelia Mouhadeb
Odelia Mouhadeb
SSShani Ben Shlomo
Shani Ben Shlomo
KCKeren Cohen
Keren Cohen
IFInbal Farkash
Inbal Farkash
SGShlomo Gruber
Shlomo Gruber
CVChen Varol
Chen Varol
Ly6Chi monocyte tissue infiltrates play important roles in mediating local inflammation, bacterial elimination and resolution during sepsis and inflammatory bowel disease (IBD). Yet, the immunoregulatory pathways dictating their activity remain poorly understood. COMMD family proteins are emerging as key regulators of signaling and protein trafficking events during inflammation, but the specific role of COMMD10 in governing Ly6Chi monocyte-driven inflammation is unknown. Here we report that COMMD10 curbs canonical and non-canonical inflammasome activity in Ly6Chi monocytes in a model of LPS-induced systemic inflammation. Accordingly, its deficiency in myeloid cells, but not in tissue resident macrophages, resulted in increased Ly6Chi monocyte liver and colonic infiltrates, elevated systemic cytokine storm, increased activation of caspase-1 and-11 in the liver and colon, and augmented IL-1β production systemically and specifically in LPS-challenged circulating Ly6Chi monocytes. These inflammatory manifestations were accompanied by impaired intestinal barrier function with ensuing bacterial dissemination to the mesenteric lymph nodes and liver leading to increased mortality. The increased inflammasome activity and intestinal barrier leakage were ameliorated by the inducible ablation of COMMD10-deficient Ly6Chi monocytes. In consistence with these results, COMMD10-deficiency in Ly6Chi monocytes, but not in intestinal-resident lamina propria macrophages, led to increased IL-1β production and aggravated colonic inflammation in a model of DSS-induced colitis. Finally, COMMD10 expression was reduced in Ly6Chi monocytes and their corresponding human CD14hi monocytes sorted from mice subjected to DSS-induced colitis or from IBD patients, respectively. Collectively, these results highlight COMMD10 as a negative regulator of Ly6Chi monocyte inflammasome activity during systemic inflammation and IBD.