The in-plane seismic performance of old unreinforced brick masonry walls strengthened with stainless-steel twisted bars and conventional steel bars (usually used in concrete reinforcing) was investigated in the present study. For this purpose, a total of seventeen masonry wallettes reproducing masonry walls of traditional Lisbon buildings from the 1930s–1950s (known as “placa” buildings) were constructed. The specimens were assembled using original bricks from demolished old buildings and a sand-cement bedding mortar with the same proportions as reported in building design documents of the time. Out of the fourteen wallettes tested in diagonal compression, three were unreinforced, and eleven were strengthened in different layouts. Additionally, axial compression tests were performed on the other three unreinforced masonry wallettes. The tested specimens were reproduced with numerical models calibrated based on the experimental results. The experimental and numerical results of the reinforced specimens were compared to the unreinforced specimens to draw conclusions on the effectiveness of the strengthening solutions when applied to masonry walls of the typology under study. The most important result of the strengthening was an important increase in the ductility of the specimens that were originally brittle. In addition, in some cases a slight increase of shear strength was also observed.
Old masonry buildings, which are frequently part of the cities-built heritage, are vulnerable to seismic actions. Thus, it is important to conduct efficient seismic strengthening interventions that allow maintenance of the existing building to minimize the environmental and economic impact. The use of reinforced renders is a simple and effective solution for seismic strengthening of this type of constructions. In this paper, several compositions of reinforced renders are analyzed, consisting of mortars with air lime, hydraulic lime, or cement binders, reinforced with steel mesh, fiberglass mesh and a natural fiber mesh. Additionally, the results of diagonal compression tests on three small wall specimens are presented, one of which is non-reinforced and the other two are strengthened with reinforced renders. The results of all tested walls are presented and compared, allowing us to evaluate the efficiency of the reinforced render on the wall shear strength.
This paper addresses the planar measurement problem in the destructive mechanical testing of masonry specimens, describing the proposed optical measurement solution. The adopted affine geometrical camera model is described as well as its experimental implementation using a digital camera and a measurement referential traceable to the International System of Units (SI). Experimental results from non-destructive tests are presented and discussed, including measurements obtained from the use of classical contact instrumentation. Measurement estimates and uncertainties related to the quantified mechanical properties are also shown.