Ana Isabel Mera Marques

Dr. Ana Isabel Mera Marques

LNEC – National Laboratory of Civil Engineering, 1700-075 Lisbon, Portugal
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
AMAna Isabel Mera Marques
Ana Isabel Mera Marques
JMJoão Morais
João Morais
PMPaulo Morais
Paulo Morais
Maria Rosario do Rosário da Silva VeigaMaria Rosario do Rosário da Silva Veiga
Maria Rosario do Rosário da Silva Veiga
CSCarlos Manuel Almeida Santos
Carlos Manuel Almeida Santos
João Gomes FerreiraJoão Gomes Ferreira
João Gomes Ferreira

31 March 2022 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
Vasco BernardoVasco Bernardo
Vasco Bernardo
ACAlfredo Peres de Noronha Campos Costa
Alfredo Peres de Noronha Campos Costa
PCPaulo Candeias
Paulo Candeias
ACAníbal Guimarães Costa
Aníbal Guimarães Costa
AMAna Isabel Mera Marques
Ana Isabel Mera Marques
Alexandra CarvalhoAlexandra Carvalho
Alexandra Carvalho

31 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Armando DemajArmando Demaj
Armando Demaj
AGAntónio Sousa Gago
António Sousa Gago
AMAna Isabel Mera Marques
Ana Isabel Mera Marques
João Gomes FerreiraJoão Gomes Ferreira
João Gomes Ferreira
The in-plane seismic performance of old unreinforced brick masonry walls strengthened with stainless-steel twisted bars and conventional steel bars (usually used in concrete reinforcing) was investigated in the present study. For this purpose, a total of seventeen masonry wallettes reproducing masonry walls of traditional Lisbon buildings from the 1930s–1950s (known as “placa” buildings) were constructed. The specimens were assembled using original bricks from demolished old buildings and a sand-cement bedding mortar with the same proportions as reported in building design documents of the time. Out of the fourteen wallettes tested in diagonal compression, three were unreinforced, and eleven were strengthened in different layouts. Additionally, axial compression tests were performed on the other three unreinforced masonry wallettes. The tested specimens were reproduced with numerical models calibrated based on the experimental results. The experimental and numerical results of the reinforced specimens were compared to the unreinforced specimens to draw conclusions on the effectiveness of the strengthening solutions when applied to masonry walls of the typology under study. The most important result of the strengthening was an important increase in the ductility of the specimens that were originally brittle. In addition, in some cases a slight increase of shear strength was also observed.

16 June 2022 in Buildings
Verified
Journal Article
Open access
PDF file
AMAna Isabel Mera Marques
Ana Isabel Mera Marques
João Gomes FerreiraJoão Gomes Ferreira
João Gomes Ferreira
PCPaulo Candeias
Paulo Candeias
Maria Rosario do Rosário da Silva VeigaMaria Rosario do Rosário da Silva Veiga
Maria Rosario do Rosário da Silva Veiga
Old masonry buildings, which are frequently part of the cities-built heritage, are vulnerable to seismic actions. Thus, it is important to conduct efficient seismic strengthening interventions that allow maintenance of the existing building to minimize the environmental and economic impact. The use of reinforced renders is a simple and effective solution for seismic strengthening of this type of constructions. In this paper, several compositions of reinforced renders are analyzed, consisting of mortars with air lime, hydraulic lime, or cement binders, reinforced with steel mesh, fiberglass mesh and a natural fiber mesh. Additionally, the results of diagonal compression tests on three small wall specimens are presented, one of which is non-reinforced and the other two are strengthened with reinforced renders. The results of all tested walls are presented and compared, allowing us to evaluate the efficiency of the reinforced render on the wall shear strength.

1 January 2019 in Procedia Structural Integrity
Verified
Journal Article
Open access
AMAna Isabel Mera Marques
Ana Isabel Mera Marques
JMJoão Morais
João Morais
CSCarlos Manuel Almeida Santos
Carlos Manuel Almeida Santos
PMPaulo Morais
Paulo Morais
MVMaria Do Rosário Veiga
Maria Do Rosário Veiga

3 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Luís Filipe Lages MartinsLuís Filipe Lages Martins
Luís Filipe Lages Martins
AMAna Isabel Mera Marques
Ana Isabel Mera Marques
Álvaro Silva RibeiroÁlvaro Silva Ribeiro
Álvaro Silva Ribeiro
PCPaulo Candeias
Paulo Candeias
Maria Rosario do Rosário da Silva VeigaMaria Rosario do Rosário da Silva Veiga
Maria Rosario do Rosário da Silva Veiga
João Gomes FerreiraJoão Gomes Ferreira
João Gomes Ferreira
This paper addresses the planar measurement problem in the destructive mechanical testing of masonry specimens, describing the proposed optical measurement solution. The adopted affine geometrical camera model is described as well as its experimental implementation using a digital camera and a measurement referential traceable to the International System of Units (SI). Experimental results from non-destructive tests are presented and discussed, including measurements obtained from the use of classical contact instrumentation. Measurement estimates and uncertainties related to the quantified mechanical properties are also shown.