Christoph Braig

Dr. Christoph Braig

Institute for Applied Photonics e.V.

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Structural Dynamics
Verified
Journal Article
Open access
PDF file
CKCarlo Kleine
Carlo Kleine
MEMaria Ekimova
Maria Ekimova
MWMarc-Oliver Winghart
Marc-Oliver Winghart
SESebastian Eckert
Sebastian Eckert
OROliver Reichel
Oliver Reichel
ARArnaud Rouzée
Arnaud Rouzée
We present a novel soft x-ray spectrometer for ultrafast absorption spectroscopy utilizing table-top femtosecond high-order harmonic sources. Where most commercially available spectrometers rely on spherical variable line space gratings with a typical efficiency on the order of 3% in the first diffractive order, this spectrometer, based on a Hettrick–Underwood design, includes a reflective zone plate as a dispersive element. An improved efficiency of 12% at the N K-edge is achieved, accompanied by a resolving power of 890. The high performance of the soft x-ray spectrometer is further demonstrated by comparing nitrogen K-edge absorption spectra from calcium nitrate in aqueous solution obtained with our high-order harmonic source to previous measurements performed at the electron storage ring facility BESSY II.

16 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JPJürgen Probst
Jürgen Probst
CBChristoph Braig
Christoph Braig
AEAlexei Erko
Alexei Erko
We report on the first experimental results obtained with a newly designed instrument for high-resolution soft X-ray spectroscopy, using reflection zone plates (RZPs) on a spherical substrate. The spectrometer was tested with a fluorescence source. High-resolution flat field spectra within ±50% around the design energies were measured at an interval of 150–750 eV, using only two RZPs: the first RZP, with its design energy of 277 eV, covered the band of 150–370 eV, and the second RZP, with a design energy of 459 eV, covered the band of 350–750 eV, where the upper boundary of this energy range was defined by the Ni coating of the RZPs. The absolute quantum efficiency of the spectrometer, including the optical element and the detector, was, on average, above 10%, and reached 20% at the designed energies of the RZPs. The resolving power E/∆E exceeded 600 for energies E inside the core range of 200–550 eV.

28 September 2012 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
CBChristoph Braig
Christoph Braig
PPPeter Predehl
Peter Predehl
We present a diffractive–refractive x-ray telescope for simultaneous imaging in multiple energy bands. Based on segmented achromatic lenses, the system yields an angular resolution around 1 mas between 5 and 10 keV for a focal distance of a few 102  km. The total sensitivity, measured via the bandwidth-integrated effective area, reaches at least 103  cm2 keV. Our arrangement exploits Fresnel lenses used in higher phase shift orders for orderly protection from scattered radiation as well as reduced refractive profiles for an enhanced throughput. The telescope, which has its focal plane detector on a separated spacecraft, may be reoriented to new astrophysical targets on short timescales. Scientific applications are briefly discussed for active galactic nuclei.

7 December 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
CBChristoph Braig
Christoph Braig
ASAndrey Sokolov
Andrey Sokolov
RWRegan G. Wilks
Regan G. Wilks
XKXeniya Kozina
Xeniya Kozina
TKThomas Kunze
Thomas Kunze
MBMarcus Bär
Marcus Bär
A collimating polycapillary half lens, traditionally used in the medium and hard X-ray band, is operated at a photon energy of 36 eV for the first time. While the transmission still exceeds 50%, the measured and simulated spatial resolution and angular divergence approach 0.4 mm or less and at most 20 mrad, respectively. This unexpected, superior performance of the polycapillary optic in the extreme Ultraviolet could enable the design of an efficient, versatile and compact spectrometer for inverse photoemission spectroscopy (IPES): Its wavelength-dispersive component, a customized reflection zone plate, can maintain an energy resolution of 0.3 eV, whereas the sensitivity may be enhanced by more than one order of magnitude, compared to conventional spectrometers. Furthermore, the overall length of 0.9 m would allow for an eased alignment and evacuation. We see a significant potential for numerous polycapillary-based XUV / soft X-ray instruments in the future, in particular after further optimization for this long wavelength regime.

7 March 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
CBChristoph Braig
Christoph Braig
IZIvo Zizak
Ivo Zizak
We investigate the potential of large-scale diffractive-refractive normal-incidence transmission lenses for the development of space-based hard x-ray telescopes with an angular resolution in the range of (10−6–10−3) arcsec over a field of view that is restricted by the available detector size. Coherently stepped achromatic lenses with diameters up to 5 m for compact apertures and 13 m in the case of segmentation provide an access to spectrally resolved imaging within keV-wide bands around the design energy between 10 and 30 keV. Within an integration time of 106 s, a photon-limited 5σ sensitivity down to (10−9–10−7) s−1 cm−2 keV−1 can be achieved depending on the specific design. An appropriate fabrication strategy, feasible nowadays with micro-optical technologies, is considered and relies on the availability of high-purity carbon or polymer membranes. X-ray fluorescence measurements of various commercially available carbon-based materials prove for most of them the existence of a virtually negligible contamination by critical trace elements such as transition metals on the ppm level.

28 April 2022 in Photonics
Verified
Journal Article
Open access
PDF file
CBChristoph Braig
Christoph Braig
AEAlexei Erko
Alexei Erko
A new type of aberration-corrected time-delay compensating monochromator (TDCM) for soft X-rays is presented. Composed of two identical reflection zone plates (RZPs) on spherical substrates and an intermediate flat mirror for band-pass selection, the TDCM can operate in a wide energy range of about ±20% around the design energy of 410eV. Assuming a source size of 50μm and an angular acceptance of 1 mrad, the spectral resolving power may reach 6×102, at a pulse length as short as 4.3femtoseconds(fs). In the case of μm-sized sources, the resolution can be better than 0.1eV and the sub-fs regime could become accessible. The overall transmission efficiency varies within (4.2–6.0)% across the energy range (310–510) eV. In the complementary mode, chirped-pulse compression works as well. Depending on the properties of the source, simulations predict an up to 9-fold reduction in pulse duration, whereas ≤50% of the peak intensity is maintained.