We report on the first experimental results obtained with a newly designed instrument for high-resolution soft X-ray spectroscopy, using reflection zone plates (RZPs) on a spherical substrate. The spectrometer was tested with a fluorescence source. High-resolution flat field spectra within ±50% around the design energies were measured at an interval of 150–750 eV, using only two RZPs: the first RZP, with its design energy of 277 eV, covered the band of 150–370 eV, and the second RZP, with a design energy of 459 eV, covered the band of 350–750 eV, where the upper boundary of this energy range was defined by the Ni coating of the RZPs. The absolute quantum efficiency of the spectrometer, including the optical element and the detector, was, on average, above 10%, and reached 20% at the designed energies of the RZPs. The resolving power E/∆E exceeded 600 for energies E inside the core range of 200–550 eV.
A reliable `in situ' method for wavefront sensing in the soft X-ray domain is reported, developed for the characterization of rotationally symmetric optical elements, like an ellipsoidal mirror shell. In a laboratory setup, the mirror sample is irradiated by an electron-excited (4.4 keV), micrometre-sized (∼2 µm) fluorescence source (carbonKα, 277 eV). Substantially, the three-dimensional intensity distributionI(r) is recorded by a CCD camera (2048 × 512 pixels of 13.5 µm) at two positions along the optical axis, symmetrically displaced by ±21–25% from the focus. The transport-of-intensity equation is interpreted in a geometrical sense from plane to plane and implemented as a ray tracing code, to retrieve the phase Φ(r) from the radial intensity gradient on a sub-pixel scale. For reasons of statistical reliability, five intra-/extra-focal CCD image pairs are evaluated and averaged to an annular two-dimensional map of the wavefront error {\cal W}. In units of the test wavelength (C Kα), an r.m.s. value \sigma_{\cal{W}} = ±10.9λ0and a peak-to-valley amplitude of ±31.3λ0are obtained. By means of the wavefront, the focus is first reconstructed with a result for its diameter of 38.4 µm, close to the direct experimental observation of 39.4 µm (FWHM). Secondly, figure and slope errors of the ellipsoid are characterized with an average of ±1.14 µm and ±8.8 arcsec (r.m.s.), respectively, the latter in reasonable agreement with the measured focal intensity distribution. The findings enable, amongst others, the precise alignment of axisymmetric X-ray mirrors or the design of a wavefront corrector for high-resolution X-ray science.
We design an advanced reflective–diffractive optical element (DOE) for high-resolution, parallelized soft x-ray spectroscopy of, e.g., transition metals, here optimized for the Fe L3-edge around 706.8 eV, and demonstrate its functionality in simulations. Based on a “hybrid” reflection zone plate (RZP) on a spherical substrate, which maintains aberration-corrected focusing under a wide angular acceptance of 8.5 msr, slightly slanted grating grooves transpose the wavelength dispersion in the (−1)st diffraction order from the vertical (z) direction partially into the horizontal (y) direction, and the signal can be read out at MHz rates from a pixelated (50 μm) line detector behind an exit slit. As an advantage over conventional variable line-space gratings of equal aperture, constant resolving power is achieved across the full range of 695–715 eV. The transmission efficiency Pt and the energy resolution ΔE scale in proportion to the adjustable slit width Δh. For a source of (1.0 × 0.3) μm2 in size and Δh = 5 μm, we expect from simulations Pt ≈ 0.3% and ΔE ≈ 0.26 eV, with great potential for their ratio Pt/ΔE to be tuned. The substrate curvature of 4.5 m and the line densities ≲7.19 × 102 mm−1 are compatible with the fabrication of the Ni-coated RZP by laser lithography. In-vacuum and tabletop operation are supported by an optical path length of 490 mm. We derive the vector field of the DOE, simulate its optical function, and characterize the performance for a variable source size. Conceptual extensions for laboratories and large-scale facilities are discussed.