Eric Dorveaux

Dr. Eric Dorveaux

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2009
Verified
Conference Paper
Closed access
EDEric Dorveaux
Eric Dorveaux
DVDavid Vissiere
David Vissiere
AMAlain-Pierre Martin
Alain-Pierre Martin
NPNicolas Petit
Nicolas Petit
We address the problem of three-axis sensor calibration. Our focus is on magnetometers. Usual errors (misalignment, non-orthogonality, scale factors, biases) are accounted for. We consider a method where no specific calibration hardware is required. We solely use the fact that the norm of the sensed field must remain constant irrespective of the sensors orientation. The proposed algorithm is iterative. Its convergence is studied. Experiments conducted with MEMS sensors (magnetometers) stress the relevance of the approach.

7 June 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AMAnne-Gaëlle Le Moing
Anne-Gaëlle Le Moing
ASAndreea Mihaela Seferian
Andreea Mihaela Seferian
AMAmélie Moraux
Amélie Moraux
MAMélanie Annoussamy
Mélanie Annoussamy
EDEric Dorveaux
Eric Dorveaux
LSLaurent SERVAIS
Laurent SERVAIS
Measurement of muscle strength and activity of upper limbs of non-ambulant patients with neuromuscular diseases is a major challenge. ActiMyo® is an innovative device that uses magneto-inertial sensors to record angular velocities and linear accelerations that can be used over long periods of time in the home environment. The device was designed to insure long-term stability and good signal to noise ratio, even for very weak movements. In order to determine relevant and pertinent clinical variables with potential for use as outcome measures in clinical trials or to guide therapy decisions, we performed a pilot study in non-ambulant neuromuscular patients. We report here data from seven Duchenne Muscular Dystrophy (DMD) patients (mean age 18.5 ± 5.5 years) collected in a clinical setting. Patients were assessed while wearing the device during performance of validated tasks (MoviPlate, Box and Block test and Minnesota test) and tasks mimicking daily living. The ActiMyo® sensors were placed on the wrists during all the tests. Software designed for use with the device computed several variables to qualify and quantify muscular activity in the non-ambulant subjects. Four variables representative of upper limb activity were studied: the rotation rate, the ratio of the vertical component in the overall acceleration, the hand elevation rate, and an estimate of the power of the upper limb. The correlations between clinical data and physical activity and the ActiMyo® movement parameters were analyzed. The mean of the rotation rate and mean of the elevation rate appeared promising since these variables had the best reliability scores and correlations with task scores. Parameters could be computed even in a patient with a Brooke functional score of 6. The variables chosen are good candidates as potential outcome measures in non-ambulant patients with Duchenne Muscular Dystrophy and use of the ActiMyo® is currently being explored in home environment. Trial Registration: ClinicalTrials.gov NCT01611597

1 July 2010 in Control Engineering Practice
Verified
Journal Article
Closed access
PBP.-J. Bristeau
P.-J. Bristeau
EDEric Dorveaux
Eric Dorveaux
DVD. Vissière
D. Vissière
NPNicolas Petit
Nicolas Petit

1 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SJSylvain Jung
Sylvain Jung
MMMona Michaud
Mona Michaud
LOLaurent Oudre
Laurent Oudre
EDEric Dorveaux
Eric Dorveaux
LGLouis Gorintin
Louis Gorintin
DRDamien Ricard
Damien Ricard
This article presents an overview of fifty-eight articles dedicated to the evaluation of physical activity in free-living conditions using wearable motion sensors. This review provides a comprehensive summary of the technical aspects linked to sensors (types, number, body positions, and technical characteristics) as well as a deep discussion on the protocols implemented in free-living conditions (environment, duration, instructions, activities, and annotation). Finally, it presents a description and a comparison of the main algorithms and processing tools used for assessing physical activity from raw signals.

1 June 2011
Verified
Conference Paper
Closed access
EDEric Dorveaux
Eric Dorveaux
TBThomas Boudot
Thomas Boudot
MHMathieu Hillion
Mathieu Hillion
NPNicolas Petit
Nicolas Petit
We address the problem of estimating the position of a rigid body moving indoors. Disturbances of the magnetic field observed in buildings are used to derive a reliable velocity estimate. The estimated velocity is expressed in the body reference frame, which imposes to simultaneously reconstruct the rotation of this frame with respect to an inertial frame of reference. For this, an inertial measurement unit (IMU) is used. To maximize the accuracy of the reconstructed motion, alignment and calibration of the inertial sensors have to be carefully treated, which minimizes projection errors. A first contribution of this paper is an alignment-calibration technique combining gyrometers and accelerometers to address the attitude estimation problem. A second contribution is an observer of the velocity, the convergence of which is proved. Finally, an experimental testbench is described and experimental results are provided.

14 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SJSylvain Jung
Sylvain Jung
NLNicolas de l’Escalopier
Nicolas de l’Escalopier
LOLaurent Oudre
Laurent Oudre
CTCharles Truong
Charles Truong
EDEric Dorveaux
Eric Dorveaux
DRDamien Ricard
Damien Ricard
This paper presents a novel approach to creating a graphical summary of a subject’s activity during a protocol in a Semi Free-Living Environment. Thanks to this new visualization, human behavior, in particular locomotion, can now be condensed into an easy-to-read and user-friendly output. As time series collected while monitoring patients in Semi Free-Living Environments are often long and complex, our contribution relies on an innovative pipeline of signal processing methods and machine learning algorithms. Once learned, the graphical representation is able to sum up all activities present in the data and can quickly be applied to newly acquired time series. In a nutshell, raw data from inertial measurement units are first segmented into homogeneous regimes with an adaptive change-point detection procedure, then each segment is automatically labeled. Then, features are extracted from each regime, and lastly, a score is computed using these features. The final visual summary is constructed from the scores of the activities and their comparisons to healthy models. This graphical output is a detailed, adaptive, and structured visualization that helps better understand the salient events in a complex gait protocol.