This paper presents a new method for estimating the base capacity of open-ended steel pipe piles in sand, a difficult problem involving great uncertainty in pile foundation design. The method, referred to as the Hong Kong University (HKU) method, is based on the cone penetration test (CPT), and takes into consideration the mechanisms of annulus and plug resistance mobilization. In this method the annulus resistance is properly linked to the ratio of the pile length to the diameter—a key factor reflecting the influence of pile embedment—whereas the plug resistance is related to the plug length ratio, which reflects the degree of soil plugging in a practical yet rational way. The cone tip resistance is averaged over a zone in the vicinity of the pile base by taking into account the failure mechanism of the piles in sand, the condition of pile embedment (i.e., full or partial embedment), and the effect of soil compressibility. The predictive performance of the new method is assessed against a number of well-documented field tests including two fully instrumented large-diameter offshore piles, and through comparisons with major CPT-based methods in current engineering practice. The assessment indicates that the HKU method has attractive capabilities and advantages that render it a promising option.
1 July 2012 in Journal of Geotechnical and Geoenvironmental Engineering
Construction effects on pile-soil systems arise from the process of installing displacement piles. This study conducted a comprehensive field test program complemented with laboratory tests to observe the performance of jacking open-ended concrete pipe piles into silt deposits. The jacked piles were examined in a plugged mode during installation. Direct observation on the soil plugs reveal that their formation generally accords with the stratigraphic nature of the layered soils. Soil-arching behavior during pile penetration causes the soil in the shear zone along the inner pipe wall to mainly come from the uppermost layer of the deposit. Laboratory tests on the soil plug shows evident compaction and the tendency increased strength over time. The buildup of the excess pore pressure and radial total stress in the soil is sensitive to the jacking installation procedure. By taking into account the soil displacement related to the plugging degree, the captured peak excess pore pressure at a given horizon can be modeled by the cavity expansion theory that normally adapts to closed-ended pile. The jacking annulus resistance normalized by the cone tip resistance is independent of the penetration depth and the degree of plugging. A considerable portion of the annulus resistance is locked in the pile after installation, decreases a little during adjacent pile installation, and remains stable over a long period.
1 April 2012 in Journal of Performance of Constructed Facilities
Open-ended steel pipe piles are now widely used as the foundations for offshore structures. The pile-soil interface behavior is of particular interest in sands where shaft friction plays an important role in resisting the applied load. The rational design of the shaft capacity depends on a good understanding of the mechanisms of interface friction during pile installation and static loading. There are two new methods on the basis of the cone penetration test results that take into account the effect of friction fatigue arising from pile installation. An improvement is made in this study to account for the influence of plugging degree, which is a key issue for open-ended piles. The significance of the modified design framework lies in that it allows for the role of plugging in a more rational way by using the soil-squeezing ratio that is closely related to the radial effective stress and, consequently, the shaft capacity. The performance of the improved method is assessed against the existing metho...
1 April 2019 in Journal of Performance of Constructed Facilities
Fiber Bragg grating (FBG) sensors emerged as a relatively new strain-sensing technology for civil engineering applications. This study presents a field test to assess the feasibility of FBG sensors in monitoring the strain profile of prestressed high-strength concrete (PHC) pipe piles during installation. Two open-ended PHC pipe piles were instrumented with FBG sensors and then driven into the ground using a hydraulic jacking machine. To measure the strain profile along the test piles, nine FBG sensors were arranged in a single optical fiber and then mounted on one pile at the opposite side to monitor the strain at different levels as a function of wavelength shift. The procedure for installing the FBG sensors along the PHC pipe piles is introduced first. Next, the distribution of the axial forces and average side shear stresses that were evaluated from the strain measurements of the FBG sensors are discussed. The field test results indicate that the FBG sensor system was suitable for monitoring the strain state of PHC pipe piles during installation. The axial forces and side shear stresses along the test piles were influenced significantly by the penetration depth and the local soil resistance.
1 August 2017 in Journal of Performance of Constructed Facilities
Development of underground space in urban areas may be obstructed by the aboveground facilities that are in good condition. Instead of building new aboveground structures, an alternative solution is to add new basements under the existing structures. One of the key issues arising from this complicated technique is the behavior of the underpinning piles. This paper considers this issue in terms of a real case recently addressed in China. The retrofit construction procedure was carefully monitored. Observations included the axial-loading and excavation-unloading responses of the underpinning piles, the axial forces transmitted from the piles to the replacing pillars, and the variations in building settlement. The results indicated that the piles acted well as an underpinning role in transferring structure load into surrounding geomaterials. The mobilization degree of the pile-shaft friction increased as the shallow strata were excavated further. Abrupt increase in pillar force and building settlement were detected when the exposed portions of the piles were cut, and therefore the cutting operation should be careful for safety control. The performance-based analyses support the pile-pillar load transmission method and offer a fairly successful reference to future applications.
1 December 2015 in Journal of Performance of Constructed Facilities
As the most important feature of jacked open-ended concrete pipe piles, shear zone has fluence of crucial importance during installing and after penetration. This study conducted a field test in silt deposit to observe the physical phenomenon of shear zone after installation and investigated soil parameter differences from undisturbed soil through laboratory tests. Direct observation on shear zone reveals that the boundary between shear zone and in situ soil is evident. The average soil thickness in the shear zone falls between 6 and 30 mm, which are closely related to natural water content and void ratio in different layers. Laboratory tests on the shear zone show evident compaction during installation, and the soil parameters in the shear zone are sensitive to the jacking installation procedure. Some soil parameters decrease, whereas others increase because of excess pore water dissipating after installation. The extent of the shear zone is helpful in understanding interface friction on pretensioned high-strength concrete (PHC) piles in clay.