Vibrational spectroscopy can provide rapid, label-free, and objective analysis for the clinical domain. Spectroscopic analysis of biofluids such as blood components (e.g. serum and plasma) and others in the proximity of the diseased tissue or cell (e.g. bile, urine, and sputum) offers non-invasive diagnostic/monitoring possibilities for future healthcare that are capable of rapid diagnosis of diseases via specific spectral markers or signatures. Biofluids offer an ideal diagnostic medium due to their ease and low cost of collection and daily use in clinical biology. Due to the low risk and invasiveness of their collection they are widely welcomed by patients as a diagnostic medium. This review underscores recent research within the field of biofluid spectroscopy and its use in myriad pathologies such as cancer and infectious diseases. It highlights current progresses, advents, and pitfalls within the field and discusses future spectroscopic clinical potentials for diagnostics. The requirements and issues surrounding clinical translation are also considered.
Surface-enhanced Raman scattering (SERS) is a powerful and sensitive technique for the detection of fingerprint sig-nals of molecules and for the investigation of a series of surface chemical reactions. Many studies introduced quantita-tive applications of SERS in various fields and several SERS methods have been implemented for each specific applica-tion, ranging in performance characteristics, analytes used, instruments, and analytical matrices. In general, very few methods have been validated according to international guidelines. As a consequence, the application of SERS in high-ly-regulated environments is still considered risky and the perception of a poorly reproducible and insufficiently robust analytical technique has persistently retarded its routine implementation. Collaborative trials are a type of interlabora-tory study (ILS) frequently performed to ascertain the quality of a single analytical method. The idea of an ILS of quan-tification with SERS arose within the framework of Working Group 1 (WG1) of the COST Action BM1401 Ra-man4Clinics32 in an effort to overcome the problematic perception of quantitative SERS methods. Here we report the first interlaboratory SERS study ever conducted, involving 15 laboratories and 41 researchers. In this study we tried to define a methodology to assess the reproducibility and trueness of a quantitative SERS method, and to compare differ-ent methods. In our opinion, this is a first important step toward a “standardization” process of SERS protocols, not proposed by a single laboratory but by a larger community.
Hepatocellular carcinoma (HCC) is the third most common cause of cancer death worldwide. The development of novel diagnostic methods is needed to detect tumours at an early stage when patients are eligible for curative treatments. The purpose of this proof-of-concept study was to determine if micro-Raman spectroscopy applied to the sera of cirrhotic patients may be an alternative method for rapidly discriminating patients with and without HCC. Serum samples were collected from 2 groups of patients: cirrhotic patients with HCC (n = 37) and without HCC (n = 34). Two different approaches were used, dried serum drops and freeze-dried serum, and micro-Raman spectra were acquired in the point-mode with a 785 nm laser excitation in the spectral range of 600–1800 cm−1. Spectra were quality-tested and pre-processed (smoothing, baseline subtraction, vector normalization). Using principal component analysis, the 2 classes, corresponding to cirrhotic patients with and without HCC, could not be differentiated. In contrast, the support vector machine method using the leave-one-out cross validation procedure was able to correctly classify the two groups of patients with an overall rate of accuracy of 84.5% to 90.2% for dried serum drops and 86% to 91.5% for freeze-dried serum. These results are promising and support the concept that serum micro-Raman spectroscopy may become a useful diagnostic tool to detect biomarkers in the field of cancer, as described here for distinguishing between cirrhotic patients with and without HCC.
Over the last few years, there has been an increased interest in the study of stem cells in biomedicine for therapeutic use and as a source for healing diseased or injured organs/tissues. More recently, vibrational spectroscopy has been applied to study stem cell differentiation. In this study, we have used both synchrotron based FTIR and Raman microspectroscopies to assess possible differences between human pluripotent (embryonic) and multipotent (adult mesenchymal) stem cells, and how O2 concentration in cell culture could affect the spectral signatures of these cells. Our work shows that infrared spectroscopy of embryonic (pluripotent) and adult mesenchymal (multipotent) stem cells have different spectral signatures based on the amount of lipids in their cytoplasm (confirmed with cytological staining). Furthermore, O2 concentration in cell culture causes changes in both the FTIR and Raman spectra of embryonic stem cells. These results show that embryonic stem cells might be more sensitive to O2 concentration when compared to mesenchymal stem cells. While vibrational spectroscopy could therefore be of potential use in identifying different populations of stem cells further work is required to better understand these differences.
Several proof-of-concept studies on the vibrational spectroscopy of biofluids have demonstrated that the methodology has promising potential as a clinical diagnostic tool. However, these studies also show that there is a lack of a standardised protocol in sample handling and preparation prior to spectroscopic analysis. One of the most important sources of analytical errors is the pre-analytical phase. For the technique to be translated into clinics, it is clear that a very strict protocol needs to be established for such biological samples. This study focuses on some of the aspects of the pre-analytical phase in the development of the high-throughput Fourier Transform Infrared (FTIR) spectroscopy of some of the most common biofluids such as serum, plasma and bile. Pre-analytical considerations that can impact either the samples (solvents, anti-coagulants, freeze–thaw cycles…) and/or spectroscopic analysis (sample preparation such as drying, deposit methods, volumes, substrates, operators dependence…) and consequently the quality and the reproducibility of spectral data will be discussed in this report.
Biofluids, such as serum and plasma, represent an ideal medium for the diagnosis of disease due to their ease of collection, that can be performed worldwide, and their fundamental involvement in human function. The ability to diagnose disease rapidly with high sensitivity and specificity is essential to exploit advances in new treatments, in addition the ability to rapidly profile disease without the need for large scale medical equipment (e.g. MRI, CT) would enable closer patient monitoring with reductions in mortality and morbidity. Due to these reasons vibrational spectroscopy has been investigated as a diagnostic tool and has shown great promise for serum spectroscopic diagnostics. However, the optimum sample preparation, optimum sampling mode and the effect of sample preparation on the serum spectrum are unknown. This paper examines repeatability and reproducibility of attenuated total reflection (ATR) compared to transmission sampling modes and their associated serum sample preparation with spectral standard deviation of 0.0015 (post pre-processing) achievable for both sampling modes proving the collection of robust spectra. In addition this paper investigates the optimum serum sample dilution factor for use in high throughput transmission mode analysis with a 3-fold dilution proving optimum and shows the use of ATR and transmission mode spectroscopy to illuminate similar discriminatory differences in a patient study. These fundamental studies provide proof of robust spectral collection that will be required to enable clinical translation of serum spectroscopic diagnostics.