Quartz enhanced photoacoustic spectroscopy (QEPAS) is a rapidly developing, ultrasensitive method for trace gas sensing. Adequate electronic amplifier, well matched to the quartz characteristics is crucial for overall system performance. Here we present an open source circuit for QEPAS signal amplification. It consists of a buffer, instrumentation amplifier and digitally controlled gain stage. An experiment showed, that it offers signal to noise ratio of about 23 dB better than commonly used transimpedance amplifier. The use of this circuit provides opportunity to improve QEPAS sensitivity by about one order of magnitude.
The optical detector of formaldehyde designed for sensing cancer biomarkers in air exhaled from human lungs with possible application in free atmosphere is described. The measurements were performed at wavelengths ranging from 3595.77–3596.20 nm. It was stated that at the pressure of 0.01 atm this absorption band exhibits the best immunity to typical interferents that might occur at high concentration in human breath. Multipass absorption spectroscopy was also applied. The method of optical fringes quenching by wavelength modulation and signal averaging over the interferences period was presented. The application of such approaches enabled the detection limit of about single ppb to be achieved.
Fast, sensitive and selective gas detection is vital for applications ranging from environmental monitoring and industrial process control to medical diagnostics. Optical detection techniques, particularly those operating in the mid-infrared, offer high selectivity and sensitivity but often suffer from complex alignment. This work presents the design, fabrication, and experimental validation of a novel antiresonant hollow-core fiber (ARHCF) with a large core diameter (107 µm) optimized for rapid mid-infrared gas sensing. The fiber features a simple geometry with 12 thin-walled silica capillaries forming the cladding, ensuring effective single-mode propagation at 3.3 µm and high flexibility. Experimental characterization confirms broad transmission bands up to 3.4 µm. When applied to methane detection using a 3.3 µm interband cascade laser, the system achieved a detection limit of 4 parts per billion with 1 second averaging time. Crucially, the enlarged core drastically reduced gas filling and response time to as low as 2.2 seconds for a 5.2 m fiber. The proposed large-core ARHCF effectively overcomes the trade off between sensitivity and response speed in hollow-core fiber-based gas sensors.
The optical sensor of ethane and formaldehyde using multipass spectroscopy in 3,3 µm range is described. Due to quenching of optical noises by novel method the detection limit of a single ppb was achieved.