Exhaled breath contains hundreds of volatile organic compounds (VOCs). Several independent researchers point out that the breath of lung cancer patients shows a characteristic VOC-profile which can be considered as lung cancer signature and, thus, used for diagnosis. In this regard, the analysis of exhaled breath with gas sensor arrays is a potential non-invasive, relatively low-cost and easy technique for the early detection of lung cancer. This clinical study evaluated the gas sensor array response for the identification of the exhaled breath of lung cancer patients. This study involved 146 individuals: 70 with lung cancer confirmed by computerized tomography (CT) or positron emission tomography—(PET) imaging techniques and histology (biopsy) or with clinical suspect of lung cancer and 76 healthy controls. Their exhaled breath was measured with a gas sensor array composed of a matrix of eight quartz microbalances (QMBs), each functionalized with a different metalloporphyrin. The instrument produces, for each analyzed sample, a vector of signals encoding the breath (breathprint). Breathprints were analyzed with multivariate analysis in order to correlate the sensor signals to the disease. Breathprints of the lung cancer patients were differentiated from those of the healthy controls with a sensitivity of 81% and specificity of 91%. Similar values were obtained in patients with and without metabolic comorbidities, such as diabetes, obesity and dyslipidemia (sensitivity 85%, specificity 88% and sensitivity 76%, specificity 94%, respectively). The device showed a large sensitivity to lung cancer at stage I with respect to stage II/III/IV (92% and 58% respectively). The sensitivity for stage I did not change for patients with or without metabolic comorbidities (90%, 94%, respectively). Results show that this electronic nose can discriminate the exhaled breath of the lung cancer patients from those of the healthy controls. Moreover, the largest sensitivity is observed for the subgroup of patients with a lung cancer at stage I.
Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.