Young Seung Lee

Dr. Young Seung Lee

Electronics and Telecommunications Research Institute (ETRI)
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
KKKyuri Kim
Kyuri Kim
YLYoung Seung Lee
Young Seung Lee
Nam KimNam Kim
Nam Kim
HCHyung-Do Choi
Hyung-Do Choi
DKDong-Jun Kang
Dong-Jun Kang
Kyung-Min LimKyung-Min Lim
Kyung-Min Lim
With the rapid growth of wireless communication devices, the influences of electromagnetic fields (EMF) on human health are gathering increasing attention. Since the skin is the largest organ of the body and is located at the outermost layer, it is considered a major target for the health effects of EMF. Skin pigmentation represents one of the most frequent symptoms caused by various non-ionizing radiations, including ultraviolet radiation, blue light, infrared, and extremely low frequency (ELF). Here, we investigated the effects of EMFs with long-term evolution (LTE, 1.762 GHz) and 5G (28 GHz) bandwidth on skin pigmentation in vitro. Murine and Human melanoma cells (B16F10 and MNT-1) were exposed to either LTE or 5G for 4 h per day, which is considered the upper bound of average smartphone use time. It was shown that neither LTE nor 5G exposure induced significant effects on cell viability or pigmentation. The dendrites of MNT-1 were neither lengthened nor regressed after EMF exposure. Skin pigmentation effects of EMFs were further examined in the human keratinocyte cell line (MNT-1-HaCaT) co-culture system, which confirmed the absence of significant hyper-pigmentation effects of LTE and 5G EMFs. Lastly, MelanoDerm™, a 3D pigmented human epidermis model, was irradiated with LTE (1.762 GHz) or 5G (28 GHz), and image analysis and special staining were performed. No changes in the brightness of MelanoDerm™ tissues were observed in LTE- or 5G-exposed tissues, except for only minimal changes in the size of melanocytes. Collectively, these results imply that exposure to LTE and 5G EMFs may not affect melanin synthesis or skin pigmentation under normal smartphone use condition.

26 July 2022 in Antioxidants
Verified
Journal Article
Open access
PDF file
KKKyuri Kim
Kyuri Kim
YLYoung Seung Lee
Young Seung Lee
Nam KimNam Kim
Nam Kim
HCHyung-Do Choi
Hyung-Do Choi
Kyung-Min LimKyung-Min Lim
Kyung-Min Lim
Recently, the impacts of 5G electromagnetic radiation (EMR) with 28 GHz on human health have been attracting public attention with the advent of 5G wireless communication. Here, we report that 5G (28 GHz) EMR can attenuate the skin pigmentation in murine melanoma cells (B16F10) and a 3D pigmented human epidermis model (Melanoderm™). B16 cells were exposed to 5G (28 GHz) with or without α-MSH for 4 h per day. Interestingly, 5G attenuated α-MSH-induced melanin synthesis. Fontana–Masson staining confirmed that the dendritic formation of α-MSH stimulated B16 cells was diminished by 5G exposure. To confirm the anti-melanogenic effect of 5G EMR, MelanoDerm™ was irradiated with 5G at a power intensity of 10 W/m2 for 4 h a day for 16 days and melanin distribution was detected with Fontana–Masson staining, which supported the anti-melanogenic effect of 5G EMR. Consistently, 5G EMR suppressed α-MSH induced upregulation of melanogenic enzymes; tyrosinase, TRP-1, and TRP-2. Of note, 5G EMR attenuated ROS production stimulated by α-MSH and H2O2, suggesting that 5G EMR may dissipate ROS generation, which is pivotal for the melanin synthesis. Collectively, we demonstrated that 5G EMR can attenuate skin pigmentation by attenuating ROS generation.

5 September 2022 in IEEE Access
Verified
Journal Article
Open access
YLYoung Seung Lee
Young Seung Lee
SJSangbong Jeon
Sangbong Jeon
JPJeong-Ki Pack
Jeong-Ki Pack
Nam KimNam Kim
Nam Kim
HCHyung-Do Choi
Hyung-Do Choi
In this study, an in vitro experimental system is developed for fifth-generation (5G) 3.5 GHz exposures. A radial transmission line (RTL) housed in an incubator can support the single-mode propagation at a 3.5 GHz band. A conical antenna is also placed at the center of an RTL to ensure field symmetries. A 5G signal generator along with a customized power amplifier can create 5G new radio time division duplex (TDD) waveforms. Additionally, a feedback scheme implemented by employing a directional coupler and power meter allows power control to ensure a steady output power. The system is evaluated based on temperature measurements using the initial temperature slope and nonlinear curve fitting to determine the specific absorption rate (SAR) values. Comparing SARs obtained from a “worst-case” signal of a maximum power condition with the values obtained from a “TDD” signal of an actual 5G TDD transmission gives the initial slope ratio of 0.741, which is very similar to the theoretical duty cycle of 0.743. It is also shown that the average output power, water temperature, incubator air temperature, and CO2 density are adequately controlled for appropriate in vitro experiments.
1

8 December 2020 in ETRI Journal
Verified
Journal Article
Open access
PDF file
YLYoung Seung Lee
Young Seung Lee
PDPhilip Ayiku Dzagbletey
Philip Ayiku Dzagbletey
JCJae‐Young Chung
Jae‐Young Chung
SJSang Bong Jeon
Sang Bong Jeon
ALAe‐Kyoung Lee
Ae‐Kyoung Lee
HCHyung‐Do Choi
Hyung‐Do Choi
The objective of this study was to implement an in vitro exposure system for 28 GHz to investigate the biological effects of fifth‐generation (5G) communication. A signal source of 28 GHz for 5G millimeter‐wave (MMW) deployment was developed, followed by a variable attenuator for antenna input power control. A power amplifier was also customized to ensure a maximum output power of 10 W for high‐power 28‐GHz exposure. A 3‐dB uniformity over the 80 mm × 80 mm area that corresponds to four Petri dishes of three‐dimensional cell cultures can be obtained using a customized choke‐ring‐type antenna. An infrared camera is employed for temperature regulation during exposure by adjusting the airflow cooling rate via real‐time feedback to the incubator. The reported measurement results confirm that the input power control, uniformity, and temperature regulation for 28‐GHz exposure were successfully accomplished, indicating the possibility of a wide application of the implemented in vitro exposure system in the fields of various MMW dose‐response studies.

31 October 2018 in Journal of Electromagnetic Engineering and Science
Verified
Journal Article
Open access
PDF file
YLYoung Seung Lee
Young Seung Lee
HLHaeng-Seon Lee
Haeng-Seon Lee
HCHyung-Do Choi
Hyung-Do Choi

10 May 2021 in IEEE Access
Verified
Journal Article
Open access
YLYoung Seung Lee
Young Seung Lee
SJSangbong Jeon
Sangbong Jeon
ALAe-Kyoung Lee
Ae-Kyoung Lee
KKKihwea Kim
Kihwea Kim
JPJeong-Ki Pack
Jeong-Ki Pack
HCHyung-Do Choi
Hyung-Do Choi
The number of fifth generation (5G) base stations (BSs) installed for commercial services continues to increase in South Korea since the first 5G rollout of the 3.5 GHz band in 2019. However, this will cause a rapid increase in the cost and effort required for an electromagnetic field (EMF) installation compliance measurements of a 5G BS. This paper studies an appropriate measurement spacing for EMF installation compliance assessments of a 3.5 GHz 5G BS. Ray-tracing simulations based on the ray frustum technique are performed for three installation scenarios according to the accessibility categories provided in the International Telecommunication Union-T K.52 recommendation to observe the power density exposure trends. An interference analysis using the two-ray propagation model indicates that the spacing of 1 m can be suitable for the installation compliance of a 5G BS above 3 GHz. In addition, it was found that this spacing could be also applied up to the higher frequency of 7.125 GHz, the upper limit of Frequency Range 1 defined in the 3rd Generation Partnership Project specification. Measurements based on two different 5G signal extrapolations using the Synchronization Signal Block were conducted to validate the spacing of 1 m for a 3.5 GHz 5G BS established by simulation studies.