It has previously been reported that different conformations of oligonucleotides may be detected using a gas-phase hydrogen/deuterium (H/D) exchange performed in the collision cell of a mass spectrometer. The presence of different conformers was postulated based on the bimodal shape of the deuterium distribution and on the ion mobility spectrometry data. Here we implement an in-electrospray ionization source H/D exchange to detect the different conformations of oligonucleotides in the region of ion formation. We observed that the number of H/D exchanges depends considerably on the temperature of the desolvating capillary and varies from 25% at 50°C to 80% at 450°C, but no bimodality in the shape of the deuterium distribution was observed. Such results indicate that in the region of ion formation different conformations of oligonucleotide ions rapidly interconvert one into another.
Metastasis is a serious and often life-threatening condition, representing the leading cause of death among women with breast cancer (BC). Although the current clinical classification of BC is well-established, the addition of minimally invasive laboratory tests based on peripheral blood biomarkers that reflect pathological changes in the body is of utmost importance. In the current study, the serum proteome and lipidome profiles for 50 BC patients with (25) and without (25) metastasis were studied. Targeted proteomic analysis for concertation measurements of 125 proteins in the serum was performed via liquid chromatography–multiple reaction monitoring mass spectrometry (LC–MRM MS) using the BAK 125 kit (MRM Proteomics Inc., Victoria, BC, Canada). Untargeted label-free lipidomic analysis was performed using liquid chromatography coupled to tandem mass-spectrometry (LC–MS/MS), in both positive and negative ion modes. Finally, 87 serum proteins and 295 lipids were quantified and showed a moderate correlation with tumor grade, histological and biological subtypes, and the number of lymph node metastases. Two highly accurate classifiers that enabled distinguishing between metastatic and non-metastatic BC were developed based on proteomic (accuracy 90%) and lipidomic (accuracy 80%) features. The best classifier (91% sensitivity, 89% specificity, AUC = 0.92) for BC metastasis diagnostics was based on logistic regression and the serum levels of 11 proteins: alpha-2-macroglobulin, coagulation factor XII, adiponectin, leucine-rich alpha-2-glycoprotein, alpha-2-HS-glycoprotein, Ig mu chain C region, apolipoprotein C-IV, carbonic anhydrase 1, apolipoprotein A-II, apolipoprotein C-II and alpha-1-acid glycoprotein 1.
Real-time molecular navigation of tissue surgeries is an important goal at present. Combination of electrosurgical units and mass spectrometry (MS) to perform accurate molecular visualization of biological tissues has been pursued by many research groups. Determination of molecular tissue composition at a particular location by surgical smoke analysis is now of increasing interest for clinical use. However, molecular analysis of surgical smoke is commonly lacking molecular specificity and is associated with significant carbonization and chemical contamination, which are mainly related to the high temperature of smoke at which many molecules become unstable. Unlike traditional electrosurgical tools, low-temperature electrosurgical units allow tissue dissection without substantial heating. Here, we show that low-temperature electrosurgical units can be used for desorption of molecules from biological tissues without thermal degradation. The use of extractive electrospray ionization technique for the ionization of desorbed molecules allowed us to obtain mass spectra of healthy and pathological tissues with high degree of differentiation. Overall, the data indicate that the described approach has potential for intraoperative use.