A low-cost video laryngoscope (VDL) called Hybrid 1.0 was developed using smart devices for visualization. To test its performance, we compared it with a high-end VDL device, using both in vitro and in vivo studies. During the in vitro study, medical students without experience in airway intubation were randomly asked to intubate a mannequin with different degrees of difficulty (Cormack–Lehane scales) by using either the Hybrid 1.0 VDL (GI) or a conventional laryngoscope (GII). During the in vivo study, N = 60 endotracheal intubations were performed by resident and base physicians, divided into two groups; the first group intubated with the Hybrid 1.0 VDL (GI) while the second group used a VDL C-Mac shovel (GII). As performance indexes, both studies reported the number of successful intubations (correct capnography signal) and intubation time. For the in vitro testing, no statistically significant differences were found regarding the number of successful intubations, while statistically significant differences were found regarding the intubation times. During the in vivo tests, procedures were performed by residents and by base physicians, and no statistically significant differences were found. The provided results point out that the VDL proposed can be clinically useful and offers technical characteristics similar to other VDLs that currently exist on the market.

7 November 2024 in Maternal-Fetal Medicine
Verified
Journal Article
Open access
VKVenance Basil Kway
Venance Basil Kway
JRJosé Enrique Calacuayo Rojas
José Enrique Calacuayo Rojas
JCJosué Sidonio Rodríguez Cuevas
Josué Sidonio Rodríguez Cuevas
UMUrsula Medina Moreno
Ursula Medina Moreno
JJJosé Sergio Camacho Juárez
José Sergio Camacho Juárez
AMAntonio Gordillo Moscoso
Antonio Gordillo Moscoso
Objective: To validate the hematocrit percentage drop cutoff points for blood loss in patients with postpartum hemorrhage (PPH) using the automated gravimetric method. Methods: A prospective cohort study was conducted from January 2023 to July 2023, in which 107 patients 18 years of age and above were scheduled for elective cesarean with obstetrical indications. We excluded cases with difficulty quantifying blood loss, those with incomplete data, and those of patients who did not consent to participate. Blood loss was measured by an automated gravimetric system integrated into a suction blood collector and surgical gauze weighing systems to automatically sum up blood loss immediately after hysterectomy and fetal delivery. The percentage drop in hematocrit was determined by subtracting the 8-hour postsurgical from presurgical hematocrit, divided by presurgical hematocrit. We performed the Pearson correlation test, and the receiver operating characteristic curve was used to determine cutoff points, their sensitivity, and their specificity. The κ index was used to determine the diagnostic agreement between the two methods. Results: A positive correlation was observed between the volume of blood loss and the percentage drop in hematocrit, with a Pearson correlation index of 0.70 and P < 0.0001. A 14% decrease in hematocrit had an 81.7% agreement rate, with a good κ index of 0.602, a sensitivity of 82.5%, and a specificity of 80.0%. A 10% drop in hemoglobin was sensitive (93.0%) but not very specific (56.0%) for blood loss greater than 1000 mL. Conclusion: The automated gravimetric method strongly correlates with hematocrit changes, providing an accurate real-time diagnosis of PPH. Additionally, a hematocrit percentage drop can retrospectively indicate significant blood loss, aiding in managing patients at risk for long-term PPH complications.