Linglong Meng

Mr. Linglong Meng


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
TLTianxin Li
Tianxin Li
LMLinglong Meng
Linglong Meng
UHUwizeyimana Herman
Uwizeyimana Herman
ZLZhongming Lu
Zhongming Lu
JCJohn Crittenden
John Crittenden
Soil quality is critical to the management of urban green space, in particular, along traffic corridors where traffic-related air pollution is significant. Soil quality can be evaluated by soil enzyme activities, which show quick responses to both natural and anthropogenic disturbances. In this study, we investigated three soil enzyme activities (i.e., dehydrogenase, catalase and urease) along the major roads in urban areas of Beijing. Results show the activities of dehydrogenase, catalase and urease in urban samples were 58.8%, 68.2% and 48.5% less than the rural sample, respectively. The content of fluorescent amino acids as indicators of microbial activities was also consistently lower in urban samples than the rural. We observed two times greater exposure of particulate material along the roadsides in urban areas than rural areas. Although traffic air pollutants provide some nutrient sources to stimulate the URE activity, the exposure to traffic-related air pollution leads to the substantial decrease in enzyme activities. There were significant negative correlations for exposure to PM10 with DHA (r = −0.8267, p = 0.0017) and CAT (r = −0.89, p = 0.0002) activities. For the urban soils URE activity increased with the increasing of PM. We conclude that the degraded soil quality can negatively affect the target of developing plants and green spaces along the traffic corridors to mitigate the traffic impact. This study suggests the investigation of integrated strategies to restore the soil quality, reinforce the ecological service functions of green spaces along the traffic corridors and reduce the traffic pollutants.

11 March 2022 in Water
Verified
Journal Article
Open access
PDF file
XCXingyu Chen
Xingyu Chen
TLTianxin Li
Tianxin Li
XDXiaomin Dou
Xiaomin Dou
LMLinglong Meng
Linglong Meng
SXShuiyang Xu
Shuiyang Xu
Flue gas desulfurization (FGD) wastewater treatment is currently of interest, as stringent standards have been released in order to limit the pollution emissions from the energy industry, and concerns about water scarcity are also increasing. Reverse osmosis (RO) membrane is a promising alternative for highly efficient FGD wastewater treatment. However, membrane fouling strongly limits its application. This study developed a suitable treatment system by combining RO membrane with ultrasonic cleaning. The introduction of low-frequency and high-intensity ultrasonic cleaning improved the cleaning efficiency of membrane fouling, as the permeate flux recovered 49% of the reduced value within 10 min of cleaning. The lifespan of the membrane was also extended, as the time of permeate flux declined to the same level, increasing from 2 h to 4 h after ultrasonic cleaning. The effluent of the system could meet the standard of desulfurization wastewater treatment. The treatment system is feasible for FGD wastewater treatment at a laboratory scale. These findings proved that the combination of RO membrane and ultrasonic cleaning could be applied to FGD wastewater treatment. The study provided an efficient, cost-saving, and convenient way to develop the FGD wastewater treatment system.

31 March 2016 in SpringerPlus
Verified
Journal Article
Open access
PDF file
TLTianxin Li
Tianxin Li
LLLi Li
Li Li
HSHongqing Song
Hongqing Song
LMLinglong Meng
Linglong Meng
SZShuli Zhang
Shuli Zhang
GHGang Huang
Gang Huang
This study focused on using analytical and numerical models to develop and manage groundwater resources, and predict the effects of management measurements in the groundwater system. Movement of contaminants can be studied based on groundwater flow characteristics. This study can be used for prediction of ion concentration and evaluation of groundwater pollution as the theoretical basis. The Yimin open-pit mine is located in the northern part of the Inner Mongolia Autonomous Region of China. High concentrations of iron and manganese are observed in Yimin open-pit mine because of exploitation and pumping that have increased the concentration of the ions in groundwater. In this study, iron was considered as an index of contamination, and the solute model was calibrated using concentration observations from 14 wells in 2014. The groundwater flow model and analytical solutions were used in this study to forecast pollution concentration and variation trend after calibration. With continuous pumping, contaminants will migrate, and become enriched, towards the wellhead in the flow direction. The concentration of the contaminants and the range of pollution increase with the flow rate increased. The suitable flow rate of single well should be <380 m/day at Yimin open-pit for the standard value of pollution concentration.

1 January 2016 in Journal of Advanced Oxidation Technologies
Verified
Journal Article
Closed access
PDF file
TLTianxin Li
Tianxin Li
XZXin Zhang
Xin Zhang
SWShiling Wu
Shiling Wu
LMLinglong Meng
Linglong Meng
HIHarrison Odion Ikhumhen
Harrison Odion Ikhumhen
In this study, the clinoptilolite is taken as the matrix, manganese nitrate as a modifier; through a medium temperature calcination pore making technique. Mostly, the micro pores in the matrix have been enlarged through the means of dipping and high temperature calcination modification. A small amount of active catalytic components are exchanged stably between the pores and surface. The mechanism of manufacturing new catalyst is analyzed using test methods of TEM, SEM, EDS, XRD and BET. These test methods testify the existence of active catalytic components of manganese in the Mn-Zeolite, while researching a new type of Mn-zeolite catalyst heterogeneous catalytic mechanism of Fenton and ozone oxidation process. The results show that added Mn-zeolite could improve the oxidation rate from 51% to 100%. Addition of free radical inhibitor, t-butanol, significantly inhibited the catalytic reaction of Fenton and ozone oxidation. This indicated that the mechanism of the reaction of Fenton and ozonation followed the hydroxyl radical.