“One-pot regeneration”, which is simple regneneration method of ammonia borane (AB) using hydrazine and liquid ammonia, enables conversion of AB from hexagonal boron nitride (h-BN) after milling hydrogenation. Solution 11B-NMR revealed the presence of AB after NH3/N2H4 treatment of milled h-BN (BNHx) although the yield of AB was less than 5%. The conversion mechanism was clarified as B-H bonds on the h-BN surface created by ball-milling under hydrogen pressure have an ability to form AB, which was confirmed by Thermogravimetry-Residual Gas Analysis (TG-RGA) and Infrared (IR) analysis. The reaction routes are also the same as regeneration route of polyborazylene because intermediates of AB such as (B(NH2)3 and hydrazine borane were found by solution 11B-NMR after soaking BNHx in liquid NH3 and hydrazine, respectively. Because of the fact that all reactions proceed on the h-BN surface and no reaction proceeds when neat h-BN is treated, breaking of B3N3 ring structure and then creation of B-H bond is the key issue to increase conversion yield of AB.
4 July 2025 in International Journal of Hydrogen Energy
Fundamental properties of ammonia borane (AB) aqueous solution were experimentally investigated in this study. The enthalpy change of dissolution ∆dissolH° for AB aqueous solution was 17.1 ± 0.9 kJ/mol, which was evaluated by heat of dissolution at each concentration. The freezing points and solubility curve were obtained by the concentration and density of AB aqueous solution at each concentration and temperature. The eutectic and transformation temperatures of AB aqueous solution were obtained by thermal analysis which were cooling/heating curves and heating profiles by differential scanning calorimetry (DSC). The stabilities (shelf-life) of 0.1 mol/L AB aqueous solution at room temperature and 8 mol/L solution at 30 and 40 °C were evaluated. It was suggested that the AB aqueous solution should be stored with non-exposure to air at room temperature by a year but less than 40 °C. From the experimental data, a phase diagram was drawn by the freezing points, solubility curve, and thermal analysis. Respectively, the estimated eutectic concentration and temperature from this phase diagram was found to be 8.93 wt.% (2.75 mol/L) and -5 °C. Based on these results, it is suggested that AB aqueous solution should be handled at above -5 °C and below 40 °C.
1 September 2023 in Review of Scientific Instruments
A relatively accurate, inexpensive, simple, and continuous quantification system for hydrogen and impurity gas(es) using a detector tube was developed in this study. Additionally, different detector tubes can be applied to measure different types of gases in a wide range from ppm order to % level. We optimized this system and evaluated its accuracy as well as the behavior of released H2 and impurity (NH3) gases from a hydrolysis of ammonia borane using a Pt/Al2O3 catalyst. The accuracy of hydrogen quantitation achieved by this system was comparable to that of commercial mass flow meters, and the accuracy of ammonia quantitation was 10% or 5% relative standard deviation, which depends on the detector tube. The concentration of released NH3 was evaluated by image analysis with a time-lapse video of the detector tube and succeeded in analyzing from ppm to % order. The H2 and NH3 release behaviors agreed with pH, and the percentage of reaction was estimated by NMR measurement of the reacted solution. These results confirmed the accuracy of this system.