Objective Teeth can serve as records of environmental exposure to heavy metals during their formation. We applied a new technology — synchrotron radiation microbeams (SRXRF) — for analysis of heavy metals in human permanent teeth in modern and historical samples. Methods Each tooth was cut in half. A longitudinal section 200 μm in thickness was subjected to the determination of the heavy metal content by SRXRF or conventional analytical methods (ICP-MS analysis or reduction–aeration atomic absorption spectrometry). The relative concentrations of Pb, Hg, Cu and Zn measured by SRXRF were translated in concentrations (in g of heavy metal/g of enamel) using calibration curves by the two analytical methods. Results Concentrations in teeth in the modern females (n = 5) were 1.2 ± 0.5 μg/g (n = 5) for Pb; 1.7 ± 0.2 ng/g for Hg; 0.9 ± 1.1 μg/g for Cu; 150 ± 24.6 μg/g for Zn. The levels of Pb were highest in the teeth samples obtained from the humans of the Edo era (1603–1868 ad) (0.5–4.0 μg/g, n = 4). No trend was observed in this study in the Hg content in teeth during 3,000 years. The concentrations of Cu were highest in teeth of two medieval craftsmen (57.0 and 220 μg/g). The levels of Zn were higher in modern subjects (P < 0.05) than those in the Jomon (~1000 bc) to Edo periods [113.2 ± 27.4 (μg/g, n = 11)]. Reconstruction of developmental exposure history to lead in a famous court painter of the Edo period (18th century) revealed high levels of Pb (7.1–22.0 μg/g) in his childhood. Conclusions SRXRF is useful a method for reconstructing human exposures in very long trends.
25 June 2019 in Journal of Japan Institute of Light Metals
A relatively accurate, inexpensive, simple, and continuous quantification system for hydrogen and impurity gas(es) using a detector tube was developed in this study. Additionally, different detector tubes can be applied to measure different types of gases in a wide range from ppm order to % level. We optimized this system and evaluated its accuracy as well as the behavior of released H2 and impurity (NH3) gases from a hydrolysis of ammonia borane using a Pt/Al2O3 catalyst. The accuracy of hydrogen quantitation achieved by this system was comparable to that of commercial mass flow meters, and the accuracy of ammonia quantitation was 10% or 5% relative standard deviation, which depends on the detector tube. The concentration of released NH3 was evaluated by image analysis with a time-lapse video of the detector tube and succeeded in analyzing from ppm to % order. The H2 and NH3 release behaviors agreed with pH, and the percentage of reaction was estimated by NMR measurement of the reacted solution. These results confirmed the accuracy of this system.