Guan-Chun Chen

Mr. Guan-Chun Chen

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2016 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
Jian-Xing WuJian-Xing Wu
Jian-Xing Wu
GCGuan-Chun Chen
Guan-Chun Chen
MWMing-Jui Wu
Ming-Jui Wu
Chia-Hung LinChia-Hung Lin
Chia-Hung Lin
TCTainsong Chen
Tainsong Chen

3 December 2015 in Materials
Verified
Journal Article
Open access
PDF file
GCGuan-Chun Chen
Guan-Chun Chen
HCHsing-Jung Chiang
Hsing-Jung Chiang
KLKuan-Hung Lin
Kuan-Hung Lin
CLChien-Ming Li
Chien-Ming Li
PCPei-Jarn Chen
Pei-Jarn Chen
TCTainsong Chen
Tainsong Chen
The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastography, the eSNR and depth of ultrasound penetration must be increased using chirp-coded excitation. Moreover, the low axial resolution of ultrasound images generated by a chirp-coded pulse must be increased using an appropriate compression filter. The main aim of this study is to develop an ultrasound elasticity imaging system with chirp-coded excitation using a Tukey window for assessing the biomechanical properties of soft tissues. In this study, we propose an ultrasound elasticity imaging system equipped with a 7.5-MHz single-element transducer and polymethylpentene compression plate to measure strains in soft tissues. Soft tissue strains were analyzed using cross correlation (CC) and absolution difference (AD) algorithms. The optimal parameters of CC and AD algorithms used for the ultrasound elasticity imaging system with chirp-coded excitation were determined by measuring the elastographic signal-to-noise ratio (SNRe) of a homogeneous phantom. Moreover, chirp-coded excitation and short pulse excitation were used to measure the elasticity properties of the phantom. The elastographic qualities of the tissue-mimicking phantom were assessed in terms of Young’s modulus and elastographic contrast-to-noise ratio (CNRe). The results show that the developed ultrasound elasticity imaging system with chirp-coded excitation modulated by a Tukey window can acquire accurate, high-quality elastography images.