Background: Weaning is typically regarded as a process of discontinuing mechanical ventilation in the daily practice of an intensive care unit (ICU). Among the ICU patients, 39%-40% need mechanical ventilator for sustaining their lives. The predictive rate of successful weaning achieved only 35-60% for decisions made by physicians. Clinical decision support systems (CDSSs) are promising in enhancing diagnostic performance and improve healthcare quality in clinical setting. To our knowledge, a prospective study has never been conducted to verify the effectiveness of the CDSS in ventilator weaning before. In this study, the CDSS capable of predicting weaning outcome and reducing duration of ventilator support for patients has been verified. Methods: A total of 380 patients admitted to the respiratory care center of the hospital were randomly assigned to either control or study group. In the control group, patients were weaned with traditional weaning method, while in the study group, patients were weaned with CDSS monitored by physicians. After excluding the patients who transferred to other hospitals, refused further treatments, or expired the admission period, data of 168 and 144 patients in the study and control groups, respectively, were used for analysis. Results: The results show that a sensitivity of 87.7% has been achieved, which is significantly higher (p<0.01) than the weaning determined by physicians (sensitivity: 61.4%). Furthermore, the days using mechanical ventilator for the study group (38.41 ± 3.35) is significantly (p<0.001) shorter than the control group (43.69 ± 14.89), with a decrease of 5.2 days in average, resulting in a saving of healthcare cost of NT$45,000 (US$1,500) per patient in the current Taiwanese National Health Insurance setting. Conclusions: The CDSS is demonstrated to be effective in identifying the earliest time of ventilator weaning for patients to resume and sustain spontaneous breathing, thereby avoiding unnecessary prolonged ventilator use and decreasing healthcare cost.
5 May 2013 in Medical & Biological Engineering & Computing
Purpose: This study sought to quantify divergence eye movements and differences between divergence and convergence to smoothly moving ramp, step, and disappearing step stimuli. Methods: Eight visually normal, adult subjects participated in three experiments investigating the dynamics of responses using an infrared limbal eye tracker. Results: There were four primary findings: (1) a smooth tracking behavior was observed for slow ramps while the fast ramps elicited smooth tracking combined with a high-velocity, step-like behavior; (2) the high-velocity components observed in the faster ramps had a similar main sequence as divergence steps; (3) divergence dynamics to disappearing steps starting at the subject's near dissociated phoria level were similar to corresponding step responses; and (4) the high-velocity components from divergence ramps were dependent on initial vergence position, whereas the high-velocity components from convergence ramps were not. Conclusion: The results suggest a preprogrammed component is present in divergence similar to convergence; however, unlike convergence, the high-velocity components from divergence ramp responses are dependent on initial vergence position.
This study proposes virtual‐reality (VR) simulator system for double interventional cardiac catheterization (ICC) using fractional‐order vascular access tracker and haptic force producer. An endoscope or a catheter for diagnosis and surgery of cardiovascular disease has been commonly used in minimally invasive surgery. It needs specific skills and experiences for young surgeons or postgraduate year (PGY) students to operate a Berman catheter and a pigtail catheter in the inside of the human body and requires avoiding damaging vessels. To improve the training in inserting catheters, a double‐catheter mechanism is designed for the ICC procedures. A fractional‐order vascular access tracker is used to trace the senior surgeons’ consoled trajectories and transmit the frictional feedback and visual feedback during the insertion of catheters. Based on the clinical feeling through the aortic arch, vein into the ventricle, or tortuous blood vessels, haptic force producer is used to mock the elasticity of the vessel wall using voice coil motors (VCMs). The VR establishment with surgeons’ consoled vessel trajectories and hand feeling is achieved, and the experimental results show the effectiveness for the double ICC procedures.
6 May 2016 in Medical & Biological Engineering & Computing