Jie Jin

Dr. Jie Jin

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Jae-Sung KwonJae-Sung Kwon
Jae-Sung Kwon
JKJi-Yeong Kim
Ji-Yeong Kim
UMUtkarsh Mangal
Utkarsh Mangal
SJSEO JIYOUNG
SEO JIYOUNG
MLMyung-Jin Lee
Myung-Jin Lee
Sung-Hwan ChoiSung-Hwan Choi
Sung-Hwan Choi
Poly(methyl methacralyate) (PMMA) has long been used in dentistry as a base polymer for dentures, and it is recently being used for the 3D printing of dental materials. Despite its many advantages, its susceptibility to microbial colonization remains to be overcome. In this study, the interface between 3D-printed PMMA specimens and oral salivary biofilm was studied following the addition of zwitterionic materials, 2-methacryloyloxyethyl phosphorylcholine (MPC) or sulfobetaine methacrylate (SB). A significant reduction in bacterial and biofilm adhesions was observed following the addition of MPC or SB, owing to their protein-repellent properties, and there were no significant differences between the two test materials. Although the mechanical properties of the tested materials were degraded, the statistical value of the reduction was minimal and all the properties fulfilled the requirements set by the International Standard, ISO 20795-2. Additionally, both the test materials maintained their resistance to biofilm when subjected to hydrothermal fatigue, with no further deterioration of the mechanical properties. Thus, novel 3D-printable PMMA incorporated with MPC or SB shows durable oral salivary biofilm resistance with maintenance of the physical and mechanical properties.

1 March 2024 in BioNanoScience
Verified
Journal Article
Closed access
PDF file
GGG. Gnanamoorthy
G. Gnanamoorthy
Virendra Kumar YadavVirendra Kumar Yadav
Virendra Kumar Yadav
JJJie Jin
Jie Jin
SMS. Munusamy
S. Munusamy
VNV. Narayanan
V. Narayanan
ZLZiyang Lu
Ziyang Lu


5 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
GKGi-tae Kim
Gi-tae Kim
JJJie Jin
Jie Jin
UMUtkarsh Mangal
Utkarsh Mangal
KLKee-Joon Lee
Kee-Joon Lee
KKKwang-Mahn Kim
Kwang-Mahn Kim
Jae-Sung KwonJae-Sung Kwon
Jae-Sung Kwon
The increasing demand for orthodontic treatment over recent years has led to a growing need for the retrieval and reuse of titanium-based miniscrews to reduce the cost of treatment, especially in patients with early treatment failure due to insufficient primary stability. This in vitro study aimed to evaluate differences in the primary stability between initially inserted and re-inserted miniscrews within different cortical bone densities. Artificial bone was used to simulate cortical bone of different densities, namely 20, 30, 40, and 50 pound per cubic foot (pcf), where primary stability was evaluated based on maximum insertion torque (MIT), maximum removal torque (MRT), horizontal resistance, and micromotion. Scanning electron microscopy was used to evaluate morphological changes in the retrieved miniscrews. The MIT, MRT, horizontal resistance, and micromotion was better in samples with higher cortical bone density, thereby indicating better primary stability (P < 0.05). Furthermore, a significant reduction of MIT, MRT, and horizontal resistance was observed during re-insertion compared with the initial insertion, especially in the higher density cortical bone groups. However, there was no significant change in micromotion. While higher cortical bone density led to better primary stability, it also caused more abrasion to the miniscrews, thereby decreasing the primary stability during re-insertion.

9 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
JJJie Jin
Jie Jin
GKGi-tae Kim
Gi-tae Kim
Jae-Sung KwonJae-Sung Kwon
Jae-Sung Kwon
Sung-Hwan ChoiSung-Hwan Choi
Sung-Hwan Choi
Miniscrews have gained recent popularity as temporary anchorage devices in orthodontic treatments, where failure due to sinus perforations or damage to the neighboring roots have increased. Issues regarding miniscrews in insufficient interradicular space must also be resolved. This study aimed to evaluate the primary stability of miniscrews shorter than 6 mm and their feasibility in artificial bone with densities of 30, 40, and 50 pounds per cubic foot (pcf). The primary stability was evaluated by adjusting the intrabony miniscrew length, based on several physical properties: maximum insertion torque (MIT), maximum removal torque (MRT), removal angular momentum (RAM), horizontal resistance, and micromotion. The MIT and micromotion results demonstrated that the intrabony length of a miniscrew significantly affected its stability in low-density cortical bone, unlike cases with a higher cortical bone density (p < 0.05). The horizontal resistance, MRT, and RAM were affected by the intrabony length, regardless of the bone density (p < 0.05). Thus, the primary stability of miniscrews was affected by both the cortical bone density and intrabony length. The effect of the intrabony length was more significant in low-density cortical bone, where the implantation depth increased as more energy was required to remove the miniscrew. This facilitated higher resistance and a lower risk of falling out.

17 December 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
UMUtkarsh Mangal
Utkarsh Mangal
SJSEO JIYOUNG
SEO JIYOUNG
JRJeong-Hyun Ryu
Jeong-Hyun Ryu
JJJie Jin
Jie Jin
CWChengzan Wu
Chengzan Wu
Sung-Hwan ChoiSung-Hwan Choi
Sung-Hwan Choi