Schiavone Marco

Dr. Schiavone Marco

Cardiology Unit, Luigi Sacco University Hospital, Milan, Italy
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SMSchiavone Marco
Schiavone Marco
CGCecilia Gobbi
Cecilia Gobbi
Giuseppe Biondi-ZoccaiGiuseppe Biondi-Zoccai
Giuseppe Biondi-Zoccai
Fabrizio D'AscenzoFabrizio D'Ascenzo
Fabrizio D'Ascenzo
APAlberto Palazzuoli
Alberto Palazzuoli
GFGiovanni Battista Forleo
Giovanni Battista Forleo
Since an association between myocardial infarction (MI) and respiratory infections has been described for influenza viruses and other respiratory viral agents, understanding possible physiopathological links between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and acute coronary syndromes (ACS) is of the greatest importance. The initial data suggest an underestimation of ACS cases all over the world, but acute MI still represents a major cause of morbidity and mortality worldwide and should not be overshadowed during the coronavirus disease (Covid-19) pandemic. No common consensus regarding the most adequate healthcare management policy for ACS is currently available. Indeed, important differences have been reported between the measures employed to treat ACS in China during the first disease outbreak and what currently represents clinical practice across Europe and the USA. This review aims to discuss the pathophysiological links between MI, respiratory infections, and Covid-19; epidemiological data related to ACS at the time of the Covid-19 pandemic; and learnings that have emerged so far from several catheterization labs and coronary care units all over the world, in order to shed some light on the current strategies for optimal management of ACS patients with confirmed or suspected SARS-CoV-2 infection.

2 August 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AGAlessio Gasperetti
Alessio Gasperetti
FAFabrizio Assis
Fabrizio Assis
HTHemantkumar Tripathi
Hemantkumar Tripathi
MSMasahito Suzuki
Masahito Suzuki
AGAkhilesh Gonuguntla
Akhilesh Gonuguntla
HTHarikrishna Tandri
Harikrishna Tandri
Pulsed field ablation (PFA) is a non-thermal ablative approach in which cardiomyocyte death is obtained through irreversible electroporation (IRE). Data correlating the biophysical characteristics of IRE and lesion characteristics are limited. The aim of this study was to assess the effect of different procedural parameters [voltage, number of cycles (NoCs), and contact] on lesion characteristics in a vegetal and animal model for IRE. Two hundred and four Russet potatoes were used. Pulsed field ablation lesions were delivered on 3 cm cored potato specimens using a multi-electrode circular catheter with its dedicated IRE generator. Different voltage (from 300 to 1200 V) and NoC (from 1 to 5×) protocols were used. The impact of 0.5 and 1 mm catheter-to-specimen distances was tested. A swine animal model was then used to validate the results observed in the vegetable model. The association between voltage, the NoCs, distance, and lesion depth was assessed through linear regression. An almost perfect linear association between lesion depth and voltage was observed (R2 = 0.95; P < 0.001). A similarly linear relationship was observed between the NoCs and the lesion depth (R2 = 0.73; P < 0.001). Compared with controls at full contact, a significant dampening on lesion depth was observed at 0.5 mm distance (1000 V 2×: 2.11 ± 0.12 vs. 0.36 ± 0.04, P < 0.001; 2.63 ± 0.10 vs. 0.43 ± 0.08, P < 0.001). No lesions were observed at 1.0 mm distance. In a vegetal and animal model for IRE assessment, PFA lesion characteristics were found to be strongly dependent on voltage settings and the NoCs, with a quasi-linear relationship. The lack of catheter contact was associated with a dampening in lesion depth.

22 March 2024 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
SMSchiavone Marco
Schiavone Marco
FSFrancesco Solimene
Francesco Solimene
MMMassimo Moltrasio
Massimo Moltrasio
Michela CasellaMichela Casella
Michela Casella
SBStefano Bianchi
Stefano Bianchi
CTClaudio Tondo
Claudio Tondo
Introduction: Limited data exist on pulsed‐field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI).Methods: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM‐PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared.Results: Among 249 patients, 21.7% had long‐standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin‐to‐skin times (PVI‐only 68 [60−90] vs. PVI + LAPWI 70 [59−88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D‐mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh‐density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow‐up of 273 [191–379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90‐day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies.Conclusion: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real‐world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy‐only method and does not significantly extend overall procedural times.

16 August 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
LBLuigi Di Biase
Luigi Di Biase
JMJacopo Marazzato
Jacopo Marazzato
TGTara Gomez
Tara Gomez
EBEric Byun
Eric Byun
FZFengwei Zou
Fengwei Zou
XZXiao-Dong Zhang
Xiao-Dong Zhang
Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter–tissue contact impact lesion formation during PFA. A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter–tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.

22 January 2025 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
NPNicola Pierucci
Nicola Pierucci
VFVincenzo Mirco La Fazia
Vincenzo Mirco La Fazia
SMSanghamitra Mohanty
Sanghamitra Mohanty
SMSchiavone Marco
Schiavone Marco
BDBrandon Doty
Brandon Doty
ANAndrea Natale
Andrea Natale

4 July 2020 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
PDF file
Gianfranco MitacchioneGianfranco Mitacchione
Gianfranco Mitacchione
SMSchiavone Marco
Schiavone Marco
AGAlessio Gasperetti
Alessio Gasperetti
GFGiovanni Battista Forleo
Giovanni Battista Forleo
Background: Coronavirus disease 2019 (COVID-19) has been associated with myocardial involvement. Among cardiovascular manifestations, cardiac arrhythmias seem to be fairly common, although no specifics are reported in the literature. An increased risk of malignant ventricular arrhythmias and electrical storm (ES) has to be considered. Case summary: We describe a 68-year-old patient with a previous history of coronary artery disease and severe left ventricular systolic disfunction, who presented to our emergency department describing cough, dizziness, fever, and shortness of breath. She was diagnosed with COVID-19 pneumonia, confirmed after three nasopharyngeal swabs. Ventricular tachycardia (VT) storm with multiple implantable cardioverter defibrillator (ICD) shocks was the presenting manifestation of cardiac involvement during the COVID-19 clinical course. A substrate-based VT catheter ablation procedure was successfully accomplished using a remote navigation system. The patient recovered from COVID-19 and did not experience further ICD interventions. Discussion: To date, COVID-19 pneumonia associated with a VT storm as the main manifestation of cardiac involvement has never been reported. This case highlights the role of COVID-19 in precipitating ventricular arrhythmias in patients with ischaemic cardiomyopathy who were previously stable.