Jacopo Marazzato

Dr. Jacopo Marazzato

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
LBLuigi Di Biase
Luigi Di Biase
JMJacopo Marazzato
Jacopo Marazzato
AGAssaf Govari
Assaf Govari
AAAndreas Altman
Andreas Altman
CBChristopher Beeckler
Christopher Beeckler
HNHiroshi Nakagawa
Hiroshi Nakagawa
BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5–25 g), high (26–50 g), and very high (51–80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA—and their integration in the PF index equation—on lesion size (study characterization). Then, 3 different PF index thresholds—300, 450, and 600—were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r 2 =0.66; P <0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.

16 August 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
LBLuigi Di Biase
Luigi Di Biase
JMJacopo Marazzato
Jacopo Marazzato
TGTara Gomez
Tara Gomez
EBEric Byun
Eric Byun
FZFengwei Zou
Fengwei Zou
XZXiao-Dong Zhang
Xiao-Dong Zhang
Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter–tissue contact impact lesion formation during PFA. A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter–tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.

1 June 2018 in Cardiac Electrophysiology Clinics
Verified
Journal Article
Closed access
Roberto De PontiRoberto De Ponti
Roberto De Ponti
JMJacopo Marazzato
Jacopo Marazzato
GBGiuseppe Bagliani
Giuseppe Bagliani
FLFabio M. Leonelli
Fabio M. Leonelli
LPLuigi Padeletti
Luigi Padeletti

21 July 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
LBLuigi Di Biase
Luigi Di Biase
FZFengwei Zou
Fengwei Zou
ALAung N Lin
Aung N Lin
VGVito Grupposo
Vito Grupposo
JMJacopo Marazzato
Jacopo Marazzato
XZXiaodong Zhang
Xiaodong Zhang
Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52–0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.

1 January 2024 in JACC
Verified
Journal Article
Closed access
LBLuigi Di Biase
Luigi Di Biase
DLDhanunjaya J. Lakkireddy
Dhanunjaya J. Lakkireddy
JMJacopo Marazzato
Jacopo Marazzato
AVAlejandro Velasco
Alejandro Velasco
JDJuan Carlos Diaz
Juan Carlos Diaz
JRJorge Romero
Jorge Romero

Verified
Journal Article
Open access
PDF file
JMJacopo Marazzato
Jacopo Marazzato
FBFederico B. M. Blasi
Federico B. M. Blasi
Michele GolinoMichele Golino
Michele Golino
Paolo VerdecchiaPaolo Verdecchia
Paolo Verdecchia
Fabio AngeliFabio Angeli
Fabio Angeli
Roberto De PontiRoberto De Ponti
Roberto De Ponti
Because of demographic aging, the prevalence of arterial hypertension (HTN) and cardiac arrhythmias, namely atrial fibrillation (AF), is progressively increasing. Not only are these clinical entities strongly connected, but, acting with a synergistic effect, their association may cause a worse clinical outcome in patients already at risk of ischemic and/or haemorrhagic stroke and, consequently, disability and death. Despite the well-known association between HTN and AF, several pathogenetic mechanisms underlying the higher risk of AF in hypertensive patients are still incompletely known. Although several trials reported the overall clinical benefit of renin–angiotensin–aldosterone inhibitors in reducing incident AF in HTN, the role of this class of drugs is greatly reduced when AF diagnosis is already established, thus hinting at the urgent need for primary prevention measures to reduce AF occurrence in these patients. Through a thorough review of the available literature in the field, we investigated the basic mechanisms through which HTN is believed to promote AF, summarising the evidence supporting a pathophysiology-driven approach to prevent this arrhythmia in hypertensive patients, including those suffering from primary aldosteronism, a non-negligible and under-recognised cause of secondary HTN. Finally, in the hazy scenario of AF screening in hypertensive patients, we reviewed which patients should be screened, by which modality, and who should be offered oral anticoagulation for stroke prevention.