Başak Zengin

Dr. Başak Zengin

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BZBaşak Zengin
Başak Zengin
FAFatih Aydin
Fatih Aydin
On 6 February 2023, two major earthquakes occurred in the Turkish province of Kahramanmaraş. The first earthquake with a magnitude of Mw 7.7 occurred in the center of Kahramanmaras, while the second earthquake with a magnitude of Mw 7.5 occurred in the region of Elbistan. These earthquakes caused heavy damage and loss of life in the affected regions. In particular, the Elbistan region experienced both earthquakes with great severity. Following the earthquakes, damage analyses were carried out on the earthquake-affected structures in this region. In the region, 1045 buildings were destroyed, 2640 buildings were heavily damaged, and 463 buildings were moderately damaged by the earthquakes. In this study, the relation between the material quality and the damage status of the affected buildings in the Elbistan region was investigated. A total of 20 buildings with heavy and moderate damage, built both before and after the year 2000, were selected for analysis. Samples were taken from these buildings, and the compressive strength values of the samples were obtained. Further, in situ experiments featuring the Schmidt and UPV tests were performed in the buildings. The results found that the buildings lacked adequate concrete strength. In particular, the post-2000 structures recorded concrete strength values below the established standard. This study proves the necessity of following established regulations in the design and construction of buildings in earthquake-prone zones, especially with respect to the construction materials used.

24 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
PUPINAR USTA
PINAR USTA
BZBaşak Zengin
Başak Zengin
In Turkey, heat loss from existing and new buildings constitutes a large part of energy waste, so usage of suitable construction material is quite important. The building selected in this study was analyzed by applying different building materials considering the annual energy consumption allowed, and according to the different heat zones and different thicknesses of insulation material in relation to demand. The most suitable building material in terms of energy and cost uptake and cost given to the regions was determined; the results were measured in the study in terms of the maximum allowable annual heating energy requirement and the optimum values were determined. Comparison of the optimum values and the total energy consumption rates was conducted for the analyzed cities.

31 March 2022 in Journal of Energy Systems
Verified
Journal Article
Open access
PDF file
PUPINAR USTA
PINAR USTA
BZBaşak Zengin
Başak Zengin
Buildings are responsible for most of the energy consumption in countries, thence energy saving in buildings is a high priority issue. Windows and glazing types are one of the factors that greatly affect the performance of buildings, both in terms of thermal comfort and energy consumption for heating or cooling. The proper selection of window glazing is one of the effective strategies to minimize energy consumption. In this study, an office building was designed to determine the most suitable glazing type for office buildings, which is the main purpose, and the energy efficiency of the building was examined with Openstudio and Energyplus software. Energy modeling of the office building was conducted for four different types of glazing by using VRF systems for air-conditioning and a dedicated outdoor air system for ventilation. The effect of different windows glazing system properties on the energy performance and total energy need was calculated by considering the fixed indoor thermal and visual comfort conditions were evaluated. The study results indicated that energy consumption can reduce about 24.88 kBtu/ft2 (25%) using suitable glazing material.

1 November 2014 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
MÖMehmet Mustafa Önal
Mehmet Mustafa Önal
BZBaşak Zengin
Başak Zengin
AKAli Koçak
Ali Koçak
BDBilge Doran
Bilge Doran
In in many earthquake-prone regions and countries including Mediterranean area, India, the Middle East, Southeast Asia, existing buildings with its structural elements such as Reinforced Concrete (RC) beams and columns, which show little ductility, have consistently exhibited poor performance during past earthquakes and consequently unavoidable earthquake damages on these structures led to a significant loss of world cultural heritage. Therefore, appropriate strengthening techniques have to be implemented in order to improve load carrying capacities and overall ductility. This paper summarizes experimental investigations of damaged and undamaged RC beams. In this context, twenty-seven beams were tested under combined bending and shear. Eighteen RC beams were damaged and then strengthened with four different methods while nine were kept undamaged. The behavior of damaged and undamaged RC beams is discussed with emphasis on the load deflection and strain characteristics. The results indicate that the specimens strengthened with full jacketing had slightly higher load carrying capacity than the reference beams strengthened with other techniques. The experimental results can also be used for understanding the most convenient strengthened technique for damaged beams.

1 June 2020 in Canadian Journal of Civil Engineering
Verified
Journal Article
Closed access
BZBaşak Zengin
Başak Zengin
BTBurak Toydemir
Burak Toydemir
AKAli Koçak
Ali Koçak
Masonry walls are systems that are typically preferred in conventional structures. The complex structure of masonry walls makes it harder to determine wall behavior; however, wall behavior is affected by the types of material used in conventional walls and the way in which joints interact with masonry units. The aim of this study is to investigate the effect of joint thickness and material factors on wall performance. To accomplish this, materials used in historical and conventional structures are preferred. This study involved hollow bricks, clay bricks, NHL 3.5, and CEM 32.5. Three different joint thicknesses were used to set up 12 different combinations. Damage estimation of the wall was carried out by moving a live load under a constant vertical load. Different materials of different joint thicknesses and mechanical properties were studied for their effects on the wall. The results indicated that a joint thickness of 20 mm preferred in wall production was more convenient. The strength of walls produced from durable material was found to be higher.