This paper presents an overview of the literature on kinematic and calibration models of parallel mechanisms, the influence of sensors in the mechanism accuracy and parallel mechanisms used as sensors. The most relevant classifications to obtain and solve kinematic models and to identify geometric and non-geometric parameters in the calibration of parallel robots are discussed, examining the advantages and disadvantages of each method, presenting new trends and identifying unsolved problems. This overview tries to answer and show the solutions developed by the most up-to-date research to some of the most frequent questions that appear in the modelling of a parallel mechanism, such as how to measure, the number of sensors and necessary configurations, the type and influence of errors or the number of necessary parameters.
A new procedure for the calibration of an articulated arm coordinate measuring machine (AACMM) is presented in this paper. First, a self-calibration algorithm of four laser trackers (LTs) is developed. The spatial localization of a retroreflector target, placed in different positions within the workspace, is determined by means of a geometric multilateration system constructed from the four LTs. Next, a nonlinear optimization algorithm for the identification procedure of the AACMM is explained. An objective function based on Euclidean distances and standard deviations is developed. This function is obtained from the captured nominal data (given by the LTs used as a gauge instrument) and the data obtained by the AACMM and compares the measured and calculated coordinates of the target to obtain the identified model parameters that minimize this difference. Finally, results show that the procedure presented, using the measurements of the LTs as a gauge instrument, is very effective by improving the AACMM precision.
7 August 2015 in The International Journal of Advanced Manufacturing Technology
Calibration of Laser Tracker systems is based most times in the determination of its geometrical errors. Some standards as the ASME B89.4.19 (2006) and the VDI 2617-10 (2011) describe different tests to calculate the geometric misalignments that cause systematic errors in Laser Tracker measurements. These errors are caused not only because of geometrical misalignments and other sources of error must also be taken in count. In this work we want to express the errors in a kinematic form. Errors will be split in two different components, geometric and kinematic errors. The first ones depend on the offsets, tilts and eccentricity of the mechanical and optical components of the system. Kinematic errors are different for every position of the Laser tracker, so they must be formulated as functions of three system variables: range (R), vertical angle (V) and horizontal angle (H). The goal of this work is to set up an evaluation procedure to determine geometric and kinematic errors of Laser Trackers