Jesús Velázquez

Jesús Velázquez

Auto-generated profile, based on publicly available information

Jesús Velázquez

Design and Manufacturing Engineering Department, University of Zaragoza, 50018 Zaragoza, Spain

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
Jorge SantolariaJorge Santolaria
Jorge Santolaria
AMAna Cristina Majarena
Ana Cristina Majarena
DSDavid Samper
David Samper
AAAgustin Brau Avila
Agustin Brau Avila
JVJesús Velázquez
Jesús Velázquez
A new procedure for the calibration of an articulated arm coordinate measuring machine (AACMM) is presented in this paper. First, a self-calibration algorithm of four laser trackers (LTs) is developed. The spatial localization of a retroreflector target, placed in different positions within the workspace, is determined by means of a geometric multilateration system constructed from the four LTs. Next, a nonlinear optimization algorithm for the identification procedure of the AACMM is explained. An objective function based on Euclidean distances and standard deviations is developed. This function is obtained from the captured nominal data (given by the LTs used as a gauge instrument) and the data obtained by the AACMM and compares the measured and calculated coordinates of the target to obtain the identified model parameters that minimize this difference. Finally, results show that the procedure presented, using the measurements of the LTs as a gauge instrument, is very effective by improving the AACMM precision.

1 January 2013 in Procedia Engineering
Verified
Journal Article
Open access
CCC. Cajal
C. Cajal
Jorge SantolariaJorge Santolaria
Jorge Santolaria
JVJ. Velazquez
J. Velazquez
SASergio Aguado
Sergio Aguado
JAJose Antonio Albajez
Jose Antonio Albajez
One of the main disadvantages for the use of 3D printers in final product manufacturing is its lack of precision and poor dimensional accuracy. This paper proposes volumetric error compensation technique based on pattern artifacts. This technique is applied to an Objet 350V 3D printer. It is developed the kinematic model of the machine and its error functions are approximated by Legendre polynomials of order 3. As reference measurement device a Zeiss PMC MMC 850 with VAST XT scanning head is used. To materialize the points conical sockets are used that are measured automatically by a self-centering probing system. These measurements allow through an iterative optimization process to identify the coefficients of the polynomials of the error model. After manufacturing various pieces of test patterns, the results achieved are close to 80% reduction in mean error points

1 July 2016 in Journal of Manufacturing Systems
Verified
Journal Article
Closed access
SASergio Aguado
Sergio Aguado
JSJorge Santolaria
Jorge Santolaria
DSDavid Samper
David Samper
JAJuan_José Aguilar_Martín
Juan_José Aguilar_Martín
JVJesús Velázquez
Jesús Velázquez

1 July 2013 in Precision Engineering
Verified
Journal Article
Closed access
Jorge SantolariaJorge Santolaria
Jorge Santolaria
FBFrancisco-Javier Brosed
Francisco-Javier Brosed
JVJesús Velázquez
Jesús Velázquez
RJRoberto Jiménez
Roberto Jiménez

18 January 2016 in Rapid Prototyping Journal
Verified
Journal Article
Closed access
CCCarlos Cajal
Carlos Cajal
Jorge SantolariaJorge Santolaria
Jorge Santolaria
DSDavid Samper
David Samper
JVJesus Velazquez
Jesus Velazquez
Purpose: – This paper aims to present a methodology for volumetric error compensation. This technique is applied to an Objet Eden350V 3D printer and involves a custom measurement strategy. Design/methodology/approach: – The kinematic model of the printer is explained, and its error model is simplified to 18 independent error functions. Each error function is defined by a cubic Legendre polynomial. The coefficients of the polynomials are obtained through a Levenberg–Marquardt optimization process. This optimization process compares, in an iterative algorithm, nominal coordinates with actual values of the cloud of points. The points are built in the faces of a gauge artefact as conical sockets defining one unique point for each socket. These points are measured by a coordinate measuring machine self-centring measurement process. Findings: – Most of the errors of the 3D printer are systematic. It is possible to obtain an improvement of 70 per cent in terms of global mean error reduction in single points within a volume of 120 × 120 × 40 mm. The forecast of the final error compensation fully matches the actual final error. Practical implications: – This methodology can be used for accuracy improvement in additive manufacturing machines. Originality/value: – Unlike the calculation of geometric errors, the proposed parametric determination through optimization of the error model allows global error reduction, which decreases all sort of systematic errors concurrently. The proposed measurement strategy allows high reliability, high speed and operator independence in the measurement process, which increases efficiency and reduces the cost. The proposed methodology is easily translated to other rapid prototyping machines and allows scalability when replicating artefacts covering any working volume.

25 January 2016 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
SASergio Aguado
Sergio Aguado
Jorge SantolariaJorge Santolaria
Jorge Santolaria
DSD Samper
D Samper
JVJ Velazquez
J Velazquez
JAJuan_José Aguilar_Martín
Juan_José Aguilar_Martín
Volumetric verification is becoming increasingly accepted as a suitable technique with which to improve machine tool accuracy. In the same way, the use of laser trackers to obtain machine error information using the new Active Target motorised retro-reflector allows the verification of all types of machine tool throughout their workspaces. Non-linear optimisation methods and machine tool kinematic models are the mainstays of this technique. Whereas the latter provide the relationship between the nominal coordinates, the geometric errors of the machine and laser tracker measurement, the former reduces the combined influence of geometric errors by obtaining their approximation functions. However, within these two procedures, several factors affect the scope of the produced verification results. The present paper focuses on the analysis of the adequacy of commercial measurement techniques using laser trackers and the new motorised retro-reflector in a real milling machine. An examination is also made regarding the influence of the optimisation sequence defined by the identification strategy, as well as the impact of the number of measured points in relation to the employed regression functions.