Her-Hsiung Huang

Prof. Her-Hsiung Huang

Department of Dentistry, National Yang Ming Chiao Tung University, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2011 in Journal of Materials Chemistry
Verified
Journal Article
Closed access
PDF file
JLJun-Kai Lin
Jun-Kai Lin
Jun-Yen UanJun-Yen Uan
Jun-Yen Uan
CWChia-Ping Wu
Chia-Ping Wu
Her-Hsiung HuangHer-Hsiung Huang
Her-Hsiung Huang
This work presents a novel method for directly forming highly-oriented Mg–Fe–CO3 LDH coating on pure Mg samples by treating the sample in pH 5.6 aqueous Fe3+/HCO3 −/CO3 2 − at 50 °C, and then immersing it in pH 9.5 aqueous HCO3 −/CO3 2 − at 50 °C. The former step was performed to yield Mg2+ in aqueous solution at pH 5.6 by corroding the Mg sample. A two-layered thin film was thus formed on the Mg substrate, of which the outer layer (∼1 μm-thick) comprised fine platelet-like Mg–Fe–CO3 LDH. The latter treatment in pH 9.5 aqueous HCO3 −/CO3 2 − at 50 °C resulted in the growth of the fine LDH platelets into a strongly-oriented Mg–Fe–CO3 LDH. The chemical formula of the Mg–Fe–CO3 LDH is Mg0.74Fe0.26(OH)2(CO3)0.13·mH2O. The method used herein involves a metal salt-free system, which requires no addition of Mg(NO3)2 and Fe(NO3)3. Several in vitro tests of the Mg–Fe–CO3 LDH coating on a Mg sample were performed. Based on the measured contact angle between the sample surface and human whole blood, the Mg–Fe–CO3 LDH coating can improve the hydrophilicity of a pure Mg surface. According to the results of an in vitro corrosion test in revised simulated body fluid (R-SBF), the Mg–Fe–CO3 LDH coated sample had a much higher corrosion resistance than the pure Mg substrate. The results of in vitro human mesenchymal stem cell adhesion tests showed that the Mg–Fe–CO3 LDH coated sample had a better cell spreading and cell–cell interaction behavior than the pure Mg substrate.

20 February 2019 in JOM
Verified
Journal Article
Closed access
PDF file
XLXiao Liu
Xiao Liu
HYHongtao Yang
Hongtao Yang
YLYang Liu
Yang Liu
PXPan Xiong
Pan Xiong
HGHui Guo
Hui Guo
Yufeng ZhengYufeng Zheng
Yufeng Zheng

1 May 2010 in The Angle Orthodontist
Verified
Journal Article
Closed access
TLTzu-Hsin Lee
Tzu-Hsin Lee
THTa-Ko Huang
Ta-Ko Huang
SLShu-Yuan Lin
Shu-Yuan Lin
LCLi-Kai Chen
Li-Kai Chen
MCMing-Yung Chou
Ming-Yung Chou
Her-Hsiung HuangHer-Hsiung Huang
Her-Hsiung Huang
Objective: To test the hypothesis that different nickel-titanium (NiTi) archwires may have dissimilar corrosion resistance in a fluoride-containing oral environment. Materials and Methods: Linear polarization test, a fast electrochemical technique, was used to evaluate the corrosion resistance, in terms of polarization resistance (Rp), of four different commercial NiTi archwires in artificial saliva (pH 6.5) with various NaF concentrations (0%, 0.01%, 0.1%, 0.25%, and 0.5%). Two-way analysis of variance was used to analyze Rp with the factors of archwire manufacturer and NaF concentration. Surface characterizations of archwires were analyzed using scanning electron microscopy, atomic force microscopy, and x-ray photoelectron spectroscopy. Results: Both archwire manufacturer and NaF concentration had a significant influence on Rp of NiTi archwires. Different surface topography was present on the test NiTi archwires that contained the similar surface chemical structure (TiO2 and trace NiO). The surface topography did not correspond to the difference in corrosion resistance of the NiTi archwires. Increasing the NaF concentration in artificial saliva resulted in a decrease in Rp, or corrosion resistance, of all test NiTi archwires. The NiTi archwires severely corroded and showed similar corrosion resistance in 0.5% NaF-containing environment. Conclusions: Different NiTi archwires had dissimilar corrosion resistance in acidic fluoride-containing artificial saliva, which did not correspond to the variation in the surface topography of the archwires. The presence of fluoride in artificial saliva was detrimental to the corrosion resistance of the test NiTi archwires, especially at a 0.5% NaF concentration.

4 April 2011 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
CYChih‐Hsiung Yang
Chih‐Hsiung Yang
YWYu‐Tsai Wang
Yu‐Tsai Wang
WTWen‐Fa Tsai
Wen‐Fa Tsai
CAChi‐Fong Ai
Chi‐Fong Ai
MLMau‐Chin Lin
Mau‐Chin Lin
Her-Hsiung HuangHer-Hsiung Huang
Her-Hsiung Huang

1 May 2019 in Surface and Coatings Technology
Verified
Journal Article
Closed access
Her-Hsiung HuangHer-Hsiung Huang
Her-Hsiung Huang
DSDuen-Kai Shiau
Duen-Kai Shiau
CCChiang-Sang Chen
Chiang-Sang Chen
JCJean-Heng Chang
Jean-Heng Chang
SWSang Wang
Sang Wang
MWMei-Fang Wu
Mei-Fang Wu

1 October 2020 in Surface and Coatings Technology
Verified
Journal Article
Closed access
CCChiang-Sang Chen
Chiang-Sang Chen
JCJean-Heng Chang
Jean-Heng Chang
VSViritpon Srimaneepong
Viritpon Srimaneepong
JWJia-Yi Wen
Jia-Yi Wen
OTOi-Hong Tung
Oi-Hong Tung
Her-Hsiung HuangHer-Hsiung Huang
Her-Hsiung Huang