Jun-Yen Uan

Prof. Jun-Yen Uan

Department of Materials Science and Engineering, National Chung Hsing University, Taichung City 40227, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


1 October 2009 in Corrosion Science
Verified
Journal Article
Closed access
MLM.C. Lin
M.C. Lin
CTC.Y. Tsai
C.Y. Tsai
Jun-Yen UanJun-Yen Uan
Jun-Yen Uan

1 September 2007 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
Jun-Yen UanJun-Yen Uan
Jun-Yen Uan
CCC Cho
C Cho
KLK Liu
K Liu

1 August 2009 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
Jun-Yen UanJun-Yen Uan
Jun-Yen Uan
SYShih-Hao Yu
Shih-Hao Yu
MLMeng-Chang Lin
Meng-Chang Lin
LCLi-Fan Chen
Li-Fan Chen
HLHeng-I. Lin
Heng-I. Lin

15 February 2011 in Journal of Materials Chemistry
Verified
Journal Article
Closed access
PDF file
JLJun-Kai Lin
Jun-Kai Lin
Jun-Yen UanJun-Yen Uan
Jun-Yen Uan
CWChia-Ping Wu
Chia-Ping Wu
Her-Hsiung HuangHer-Hsiung Huang
Her-Hsiung Huang
This work presents a novel method for directly forming highly-oriented Mg–Fe–CO3 LDH coating on pure Mg samples by treating the sample in pH 5.6 aqueous Fe3+/HCO3 −/CO3 2 − at 50 °C, and then immersing it in pH 9.5 aqueous HCO3 −/CO3 2 − at 50 °C. The former step was performed to yield Mg2+ in aqueous solution at pH 5.6 by corroding the Mg sample. A two-layered thin film was thus formed on the Mg substrate, of which the outer layer (∼1 μm-thick) comprised fine platelet-like Mg–Fe–CO3 LDH. The latter treatment in pH 9.5 aqueous HCO3 −/CO3 2 − at 50 °C resulted in the growth of the fine LDH platelets into a strongly-oriented Mg–Fe–CO3 LDH. The chemical formula of the Mg–Fe–CO3 LDH is Mg0.74Fe0.26(OH)2(CO3)0.13·mH2O. The method used herein involves a metal salt-free system, which requires no addition of Mg(NO3)2 and Fe(NO3)3. Several in vitro tests of the Mg–Fe–CO3 LDH coating on a Mg sample were performed. Based on the measured contact angle between the sample surface and human whole blood, the Mg–Fe–CO3 LDH coating can improve the hydrophilicity of a pure Mg surface. According to the results of an in vitro corrosion test in revised simulated body fluid (R-SBF), the Mg–Fe–CO3 LDH coated sample had a much higher corrosion resistance than the pure Mg substrate. The results of in vitro human mesenchymal stem cell adhesion tests showed that the Mg–Fe–CO3 LDH coated sample had a better cell spreading and cell–cell interaction behavior than the pure Mg substrate.