The operation of steam turbine units in solar thermal power plants is very different than in conventional base-load plants. Due to the variability of the solar resource, much higher frequencies of plant start-ups are encountered. This study provides an insight to the influence of thermal energy storage (TES) integration on the typical cycling operation of solar thermal power plants. It is demonstrated that the integration of storage leads to significant reductions in the annual number of turbine starts and is thus beneficial to the turbine lifetime. At the same time, the effects of storage integration on the electricity costs are analyzed to ensure that the designs remain economically competitive. Large storage capacities, can allow the plant to be shifted from a daily starting regime to one where less than 20 plant starts occur annually. Additionally, the concept of equivalent operating hours (EOHs) is used to further analyze the direct impact of storage integration on the maintenance planning of the turbine units.
Parabolic trough power plants using thermal oil as heat transfer fluid are the most mature concentrating solar power technology and state of the art. To further increase their efficiency and lower costs, molten salts can be used as heat transfer fluid. This results in higher operating temperature differences for improved cycle efficiencies and enables direct thermal energy storage at lower costs due to omission of the oil-to-salt heat exchanger and the need for smaller storage sizes. As a variety of salts are available to choose from, this study uses a multi-objective optimization to identify the most suitable heat transfer fluid for three locations in South Africa, Spain and Chile. The lowest values for the levelized costs of electricity (LCOE) can be found in Chile using Solar Salt as heat transfer fluid (75.0 $/MWhe). Generally, Solar Salt offers the lowest LCOE values followed by thermal oil and Hitec. The results also suggest that the choice of the heat transfer fluid is dependent on the direct normal irradiance (DNI) at each location. Thermal oil is competitive with Solar Salt in small systems at locations with low DNI values, whereas Hitec can be cheaper than thermal oil in large systems at locations with high DNI. Furthermore, it is also investigated at which freeze alert temperature set point the activation of the freeze protection system is optimal. The results indicate that this temperature should be chosen close to the solar field inlet temperature for small systems, while it can be lowered significantly for large systems to reduce electricity consumption from the freeze protection system.
1 February 2016 in Journal of Solar Energy Engineering
The present study analyzes the influence that market conditions have on determining optimum molten salt solar tower plants with storage that maximizes profits (in terms of plant configuration, sizing, and operation) for a location in South Africa. Three different scenarios based on incentive programs and local wholesale electricity prices are considered. A multi-objective optimization modeling approach was followed, showing the tradeoff curves between minimizing investment and maximizing profits when varying critical size-related parameters (such as nameplate capacity, solar multiple (SM), and storage capacity) together with power-cycle design and operating specifications including dynamic startup curves and different storage dispatchability strategies. Results are shown by means of a comparative analysis between optimal plants found for each scenario, highlighting the value that storage has under the current two-tier tariff scheme and the relevance of designing a suitable policy for technology development. Finally, a final analysis is performed with regard to the indicators used for economic evaluation of power plants, by comparing the differences between optimum designs found when using the levelized cost of electricity (LCoE) solely as performance indicator instead of cash-flows and profit-based indicators, such as the internal rate of return (IRR).