Rafael Guédez

Dr. Rafael Guédez

Senior Researcher, KTH Royal Institute of Technology, Stockholm, Sweden
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

29 July 2014 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
Rafael GuédezRafael Guédez
Rafael Guédez
JSJames Spelling
James Spelling
BLBjörn Laumert
Björn Laumert
The operation of steam turbine units in solar thermal power plants is very different than in conventional base-load plants. Due to the variability of the solar resource, much higher frequencies of plant start-ups are encountered. This study provides an insight to the influence of thermal energy storage (TES) integration on the typical cycling operation of solar thermal power plants. It is demonstrated that the integration of storage leads to significant reductions in the annual number of turbine starts and is thus beneficial to the turbine lifetime. At the same time, the effects of storage integration on the electricity costs are analyzed to ensure that the designs remain economically competitive. Large storage capacities, can allow the plant to be shifted from a daily starting regime to one where less than 20 plant starts occur annually. Additionally, the concept of equivalent operating hours (EOHs) is used to further analyze the direct impact of storage integration on the maintenance planning of the turbine units.

8 November 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
CPChristoph A. Pan
Christoph A. Pan
DFDavide Ferruzza
Davide Ferruzza
Rafael GuédezRafael Guédez
Rafael Guédez
FDFrank Dinter
Frank Dinter
BLBjörn Laumert
Björn Laumert
FHFredrik Haglind
Fredrik Haglind
Parabolic trough power plants using thermal oil as heat transfer fluid are the most mature concentrating solar power technology and state of the art. To further increase their efficiency and lower costs, molten salts can be used as heat transfer fluid. This results in higher operating temperature differences for improved cycle efficiencies and enables direct thermal energy storage at lower costs due to omission of the oil-to-salt heat exchanger and the need for smaller storage sizes. As a variety of salts are available to choose from, this study uses a multi-objective optimization to identify the most suitable heat transfer fluid for three locations in South Africa, Spain and Chile. The lowest values for the levelized costs of electricity (LCOE) can be found in Chile using Solar Salt as heat transfer fluid (75.0 $/MWhe). Generally, Solar Salt offers the lowest LCOE values followed by thermal oil and Hitec. The results also suggest that the choice of the heat transfer fluid is dependent on the direct normal irradiance (DNI) at each location. Thermal oil is competitive with Solar Salt in small systems at locations with low DNI values, whereas Hitec can be cheaper than thermal oil in large systems at locations with high DNI. Furthermore, it is also investigated at which freeze alert temperature set point the activation of the freeze protection system is optimal. The results indicate that this temperature should be chosen close to the solar field inlet temperature for small systems, while it can be lowered significantly for large systems to reduce electricity consumption from the freeze protection system.

1 February 2016 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
Rafael GuédezRafael Guédez
Rafael Guédez
Monika TopelMonika Topel
Monika Topel
ICInés Conde
Inés Conde
FFFrancisco Ferragut
Francisco Ferragut
ICIrene Callaba
Irene Callaba
BLBjörn Laumert
Björn Laumert
The present study analyzes the influence that market conditions have on determining optimum molten salt solar tower plants with storage that maximizes profits (in terms of plant configuration, sizing, and operation) for a location in South Africa. Three different scenarios based on incentive programs and local wholesale electricity prices are considered. A multi-objective optimization modeling approach was followed, showing the tradeoff curves between minimizing investment and maximizing profits when varying critical size-related parameters (such as nameplate capacity, solar multiple (SM), and storage capacity) together with power-cycle design and operating specifications including dynamic startup curves and different storage dispatchability strategies. Results are shown by means of a comparative analysis between optimal plants found for each scenario, highlighting the value that storage has under the current two-tier tariff scheme and the relevance of designing a suitable policy for technology development. Finally, a final analysis is performed with regard to the indicators used for economic evaluation of power plants, by comparing the differences between optimum designs found when using the levelized cost of electricity (LCoE) solely as performance indicator instead of cash-flows and profit-based indicators, such as the internal rate of return (IRR).

4 July 2025 in Energy Conversion and Management
Verified
Journal Article
Open access
Silvia TrevisanSilvia Trevisan
Silvia Trevisan
SPSharat Pathi
Sharat Pathi
JBJames Brown
James Brown
BBBjarke Buchbjerg
Bjarke Buchbjerg
ABAndres Barros Borrero
Andres Barros Borrero
Rafael GuédezRafael Guédez
Rafael Guédez

17 May 2022 in Solar Energy
Verified
Journal Article
Open access
SGSalvatore Guccione
Salvatore Guccione
Armando Enrique FontalvoArmando Enrique Fontalvo
Armando Enrique Fontalvo
Rafael GuédezRafael Guédez
Rafael Guédez
JPJohn Pye
John Pye
Laura SavoldiLaura Savoldi
Laura Savoldi
RZRoberto Zanino
Roberto Zanino