Roberto Zanino

Roberto Zanino

Auto-generated profile, based on publicly available information

Roberto Zanino

NEMO Group, Dipartimento Energia, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Fusion Engineering and Design
Verified
Journal Article
Open access
Alessandro Del NevoAlessandro Del Nevo
Alessandro Del Nevo
PAP. Arena
P. Arena
GCGianfranco Caruso
Gianfranco Caruso
PCP. Chiovaro
P. Chiovaro
PMPietro Alessandro Di Maio
Pietro Alessandro Di Maio
EME. Martelli
E. Martelli

28 February 2020 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
KSKamil Sedlak
Kamil Sedlak
VAV A Anvar
V A Anvar
NBNadezda Bagrets
Nadezda Bagrets
MBM E Biancolini
M E Biancolini
RBRoberto Bonifetto
Roberto Bonifetto
VCValentina Corato
Valentina Corato
The European DEMO, i.e. the demonstration fusion power plant designed in the framework of the Roadmap to Fusion Electricity by the EUROfusion Consortium, is approaching the end of the pre-conceptual design phase, to be accomplished with a Gate Review in 2020, in which all DEMO subsystems will be reviewed by panels of independent experts. The latest 2018 DEMO baseline has major and minor radius of 9.1 m and 2.9 m, plasma current 17.9 MA, toroidal field on the plasma axis 5.2 T, and the peak field in the toroidal-field (TF) conductor 12.0 T. The 900 ton heavy TF coil is prepared in four low-temperature-superconductor (LTS) variants, some of them differing slightly, other significantly, from the ITER TF coil design. Two variants of the CS coils are investigated—a purely LTS one resembling the ITER CS, and a hybrid coil, in which the innermost layers made of HTS allow the designers either to increase the magnetic flux, and thus the duration of the fusion pulse, or to reduce the outer radius of the CS coil. An issue presently investigated by mechanical analyzes is the fatigue load. Two variants of the poloidal field coils are being investigated. The magnet and conductor design studies are accompanied by the experimental tests on both LTS and HTS prototype samples, covering a broad range of DC and AC tests. Testing of quench behavior of the 15 kA HTS cables, with size and layout relevant for the fusion magnets and cooled by forced flow helium, is in preparation.

1 July 2019 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
AZAndrea Zappatore
Andrea Zappatore
WFWalter H Fietz
Walter H Fietz
RHReinhard Heller
Reinhard Heller
Laura SavoldiLaura Savoldi
Laura Savoldi
MWMichael J. Wolf
Michael J. Wolf
RZRoberto Zanino
Roberto Zanino

29 November 2010 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
RZR. Zanino
R. Zanino
RBRoberto Bonifetto
Roberto Bonifetto
RHR. Heller
R. Heller
Laura SavoldiLaura Savoldi
Laura Savoldi
The first step of the validation of the recently developed thermal-hydraulic code 4C is presented. We study the transient evolution during a so-called standard 25 kA safety discharge of the International Thermonuclear Experimental Reactor (ITER) Toroidal Field Model Coil (TFMC), tested in 2001-2002 in the TOSKA facility at the Karlsruhe Institute of Technology, Germany. The computed outlet He temperatures from both winding and case cooling channels, as well as the local maximum temperature increase of the structures, are shown to be in good agreement with the measured data.

1 March 2022 in Nuclear Fusion
Verified
Journal Article
Closed access
GNG.F. Nallo
G.F. Nallo
GMG. Mazzitelli
G. Mazzitelli
MMM. Moscheni
M. Moscheni
FSFabio Subba
Fabio Subba
RZR. Zanino
R. Zanino
In this work, we study the effect of installing a liquid metal divertor (LMD) using a capillary-porous structure in the EU DEMO tokamak within the same envelope of the baseline solid divertor. We used the SOLPS-ITER code to model the scrape-off layer (SOL) plasma and neutrals, coupled to a target thermal model to enable the self-consistent calculation of the LM target erosion rate, and adopting a fluid neutral model for the sake of simplicity. First calculations considering only D and Li (or Sn) showed a significant reduction of the steady state target heat load with respect to simulations considering only D, thanks to vapor shielding. Nevertheless, the computed peak target heat flux (∼31 MW m−2 and ∼44 MW m−2 for Li and Sn, respectively) was still larger than/borderline to the power handling limit of the LMD concepts considered. Moreover, the impurity concentration in the pedestal—a proxy for the core plasma dilution/contamination—was computed to be above/close to tolerability limits suggested by previous COREDIV calculations. These results indicate that the operational window of an LMD for the EU DEMO, without any additional impurity seeding, might be too narrow, if it exists, and that Sn looks more promising than Li. A second set of calculations was then performed simulating Ar seeding in the SOL, to further reduce the target heat load, and consequently the metal erosion rate. It was found that the mitigation of the plasma heat load due to Ar radiation in the SOL effectively replaces the radiation associated to vapor shielding in front of the target, thus allowing to operate the LMD in a regime of low target erosion. The resulting operational window was found to be significantly wider, both in terms of tolerable peak target heat flux and of acceptable core plasma contamination.

3 September 2021 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
HWH. Wu
H. Wu
FSFabio Subba
Fabio Subba
MWM. Wischmeier
M. Wischmeier
MCMarco Cavedon
Marco Cavedon
RZR. Zanino
R. Zanino
SOLPS-ITER is used to model ASDEX Upgrade L-mode detachment states including the onset of detachment, the fluctuating detachment, and the complete detachment states, considering drifts and mimicking filamentary convective transport with a radial outward velocity in the low field side. The effect of drifts, perpendicular outward convection and core boundary conditions on the numerical solution is presented. The modeling results are validated against experimental data. We find a good agreement of particle flux at the inner target between modeling results and experimental data. On the opposite, at the outer target computations underestimate measured particle flux by a factor of about 2 ∼ 3 in the onset of detachment and the fluctuating detachment states.