Claire Sanders

Dr. Claire Sanders

Los Alamos National Laboratory
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2013 in Analytical Chemistry
Verified
Journal Article
Open access
Ye AiYe Ai
Ye Ai
CSClaire Sanders
Claire Sanders
BMBabetta L Marrone
Babetta L Marrone
A microfluidic device was developed to separate heterogeneous particle or cell mixtures in a continuous flow using acoustophoresis. In this device, two identical surface acoustic waves (SAWs) generated by interdigital transducers (IDTs) propagated toward a microchannel, which accordingly built up a standing surface acoustic wave (SSAW) field across the channel. A numerical model, coupling a piezoelectric effect in the solid substrate and acoustic pressure in the fluid, was developed to provide a better understanding of SSAW-based particle manipulation. It was found that the pressure nodes across the channel were individual planes perpendicular to the solid substrate. In the separation experiments, two side sheath flows hydrodynamically focused the injected particle or cell mixtures into a very narrow stream along the centerline. Particles flowing through the SSAW field experienced an acoustic radiation force that highly depends on the particle properties. As a result, dissimilar particles or cells were laterally attracted toward the pressure nodes at different magnitudes, and were eventually switched to different outlets. Two types of fluorescent microspheres with different sizes were successfully separated using the developed device. In addition, Escherichia coli bacteria premixed in peripheral blood mononuclear cells (PBMCs) were also efficiently isolated using the SSAW-base separation technique. Flow cytometric analysis on the collected samples found that the purity of separated E. coli bacteria was 95.65%.

9 October 2007 in Analytical Chemistry
Verified
Journal Article
Closed access
GGGregory R. Goddard
Gregory R. Goddard
CSClaire Sanders
Claire Sanders
JMJohn C. Martin
John C. Martin
GKGregory Kaduchak
Gregory Kaduchak
SGSteven W. Graves
Steven W. Graves

1 March 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CSClaire Sanders
Claire Sanders
JMJudith R. Mourant
Judith R. Mourant
A charge coupled device-based flow-cytometer for the measurement of full spectra was implemented and characterized. The spectral resolution was better than 1.5 nm and the coefficient of variation for fluorescence from flow check beads was 5% or better. Both cell and bead data were analyzed by fitting to measured component spectra. Separation of flow check and align flow beads, which have similar spectra, was nearly identical whether using a spectral analysis or a scatter analysis. After mixing, cells stained with ethidium bromide or propidium iodide were measured at different timepoints. The contribution of these 12 nm separated emission spectra could be separately quantified and the kinetic process of the samples becoming homogeneous due to fluorophor dissociation and rebinding was observed. Principle component analysis was used to reduce noise and alternating least squares (ALS) was used to analyze one set of noise-reduced cell data without knowledge of the component spectra. The component spectra obtained via ALS are very similar to the measured component spectra. The contributions of ethidium bromide and propidium iodide to the individual spectra are also similar to those obtained via the spectral fitting procedure.

27 September 2012 in Journal of Applied Phycology
Verified
Journal Article
Closed access
PDF file
KLKatherine S. Lovejoy
Katherine S. Lovejoy
LDLauren E. Davis
Lauren E. Davis
LMLisa M. McClellan
Lisa M. McClellan
ALAntonietta M. Lillo
Antonietta M. Lillo
JWJohn D. Welsh
John D. Welsh
RSRico E. Del Sesto
Rico E. Del Sesto

28 February 2008 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
JCJun Chen
Jun Chen
JZJianhong Zhou
Jianhong Zhou
WBWeon Bae
Weon Bae
CSClaire Sanders
Claire Sanders
JNJohn P. Nolan
John P. Nolan
HCHong Cai
Hong Cai
The yeast two-hybrid (Y2H) assay is a widely used method to study protein–protein interactions, a major objective in postgenome research. Despite the tremendous utility of the Y2H assay, several issues including accuracy, speed, automation, and cost-effectiveness limit its application in high-throughput analysis. We have created an improved Y2H assay reporter system by integrating the codon-optimized yeast enhanced green fluorescent protein (yEGFP) gene into the ADE2 locus of the AH109 yeast strain and evaluated reporter expression using the strong and weak triggers via flow cytometry. We also performed flow cytometry-based Y2H assays in liquid cultures as well as in a cDNA library screening. We have shown that yEGFP, but not EGFP, is a sensitive Y2H reporter for flow cytometric detection. We also show that this yEGFP-based Y2H could be easily adapted to high-throughput format without conventional agar plating. Moreover, our data demonstrate that this system can be used for cDNA library screening. We have developed sensitive and efficient flow cytometry-based Y2H assay system that is well suited for large-scale protein–protein interaction identification and characterization. When compared with the conventional plate and filter membrane-based nutrient and colorimetric analysis, our flow cytometric assay offers convenient, quantitative, and faster reporter analysis compatible with existing liquid handling robots. © 2008 International Society for Analytical Cytology

1 August 2012 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
OMOana C. Marina
Oana C. Marina
CSClaire Sanders
Claire Sanders
JMJudith R. Mourant
Judith R. Mourant
Acetic acid has been used for decades as an aid for the detection of precancerous cervical lesions, and the use of acetic acid is being investigated in several other tissues. Nonetheless, the mechanism of acetowhitening is unclear. This work tests some of the hypotheses in the literature and measures changes in light scattering specific to the nucleus and the cytoplasm. Wide angle side scattering from both the nucleus and the cytoplasm increases with acetic application to tumorigenic cells, with the increase in nuclear scattering being greater. In one cell line, the changes in nuclear scattering are likely due to an increase in number or scattering efficiency of scattering centers smaller than the wavelength of excitation light. There are likely several cellular changes that cause acetowhitening and the cellular changes may differ with cell type. These results should lead to a better understanding of acetowhitening and potentially the development of adjunct techniques to improve the utility of acetic acid application. For the well-studied case of cervical tissue, acetowhitening has been shown to be sensitive, but not specific for oncogenic changes needing treatment.