Yannis Caouris

Prof. Yannis Caouris


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2021 in Advances in Environmental and Engineering Research
Verified
Journal Article
Open access
PDF file
PKPanagiotis Kyriakopoulos
Panagiotis Kyriakopoulos
AGAthanassios Giannopoulos
Athanassios Giannopoulos
YCYannis Caouris
Yannis Caouris
Manolis SouliotisManolis Souliotis
Manolis Souliotis
Mst SantamourisMst Santamouris
Mst Santamouris
The hourly ambient air temperature information was analyzed for two Greek coastal Mediterranean cities: Patras (for the entire 2018 year) with ten urban and one rural stations, and Kalamata (for the entire 2019 and 2020 years) with eight urban and two rural stations. The heating and cooling Degree Hours (DH) and Degree Days (DD) were calculated, for base temperatures of 18 °C and 26 °C, respectively. The urban heating degree hours for the cities of Patras and Kalamata were observed to be 19.2% and 24%, respectively, lower than that of the rural areas. Similarly, the urban cooling degree hours for the two cities were 9% and 22% higher than that of rural areas. These findings indicate a distinct urban heat island effect in both the cities, with greater effects in Kalamata than in Patras. Following comparisons with historical data from reliable sources, it could be observed that summers are trending warmer and winters are trending milder.

2 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
MKMARIA K. KOUKOU
MARIA K. KOUKOU
CPChristos Pagkalos
Christos Pagkalos
GDGeorge Dogkas
George Dogkas
MVMichail Gr. VRACHOPOULOS
Michail Gr. VRACHOPOULOS
EDEleni Douvi
Eleni Douvi
PPPapadopoulos Polycarpos
Papadopoulos Polycarpos
A numerical study was carried out to investigate charging and discharging processes of different phase change materials (PCMs) used for thermal storage in an innovative solar collector, targeting domestic hot water (DHW) requirements. The aim was to study PCMs that meet all application requirements, considering their thermal performance in terms of stored and retrieved energy, outlet temperatures, and water flow rate. Work was carried out for three flat-plate solar panels of different sizes. For each panel, a PCM tank with a heat exchanger was attached on the back plate. Simulations were conducted on a 2D domain using the enthalpy–porosity technique. Three paraffin-based PCMs were studied, two (A53, P53) with phase-change temperatures of approximately 53 °C and one of approximately 58 °C (A58H). Results showed that, during charging, A58H can store the most energy and A53 the least (12.30 kWh and 10.54 kWh, respectively, for the biggest unit). However, the biggest unit, A58H, takes the most time to be fully charged, i.e., 6.43 h for the fastest feed rate, while the A53 unit charges the fastest, at 4.25 h. The behavior of P53 lies in between A53 and A58H, considering stored energy and charging time. During discharging, all PCMs could provide an adequate DHW amount, even in the worst case, that is, a small unit with a high hot water consumption rate. The A58H unit provides hot water above 40 °C for 10 min, P53 for 11 min, and A53 for 12 min. The DHW production duration increased if a bigger unit was used or if the consumption rate was lower.

23 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
NANektarios Arnaoutakis
Nektarios Arnaoutakis
AVAndreas P. Vouros
Andreas P. Vouros
MMMaria Milousi
Maria Milousi
YCYannis Caouris
Yannis Caouris
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
Manolis SouliotisManolis Souliotis
Manolis Souliotis
The paper presents a design and operation analysis of an Integrated Collector Storage (ICS) solar water heater, which consists of an asymmetric Compound Parabolic Concentrating (CPC) reflector trough, while the water tank comprises two concentric cylinders. The annulus between these vessels is partially depressurized and contains a small amount of water in the bottom of the outer vessel which dominantly contributes to the heat transfer from the outer to the inner cylinder. A multi-criteria optimization algorithm is applied to re-evaluate the design specifications of the parabolic surface, thus modifying the design of the entire ICS system and predict the necessary number of units for achieving the highest possible effectiveness with minimized fabrication costs and environmental impacts. The environmental footprint of the device is assessed through Life Cycle Assessment (LCA). The produced thermal energy in conjunction with the environmental and economic results are evaluated as a function of different configuration parameters regarding the water storage conditions, the solar radiation and the total pressure inside the annulus. The ultimate aim of the evaluation process is to offer new perspectives on the design principles of environmentally friendly and cost-effective devices with improved thermal performance.

3 July 2021 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
AGAthanassios Giannopoulos
Athanassios Giannopoulos
YCYannis Caouris
Yannis Caouris
Manolis SouliotisManolis Souliotis
Manolis Souliotis
Mst SantamourisMst Santamouris
Mst Santamouris
The ambient air urban heat island effect (at a height of 4÷4.5 m) is studied in the coastal city of Patras. For this purpose, 11 fixed temperature stations have been placed in chosen representative locations to monitor the ambient air temperature variations. Temperature stations are placed in urban places: at the center of the city (intense traffic), around the center (moderate traffic), and in a rural region outside the town (at ∼10 km). Collected data for June, July, August and September 2018 are examined statistically and results are extracted indicating that urban heat island effects are not very intense. An analysis of air temperatures in transverse and longitudinal to sea-line streets has shown some lower air temperatures across transversal streets.

25 June 2013 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
YCYannis Caouris
Yannis Caouris
Manolis SouliotisManolis Souliotis
Manolis Souliotis
The present work deals with the examination of two different configurations of inlet mantle connections, on a solar thermosiphon of indirect heating type. In the first configuration, the heat transfer fluid enters the upper side of the mantle heat exchanger, while in the second it enters the lower side of the mantle. The outlet is always placed at the bottom of the mantle, oppositively to the inlet. Diurnal tests have been carried out by monitoring the inlet and outlet mantle temperatures, as well as thermosiphonic flow rates. Also, draw-offs measurements were performed, according to ISO 9459-2 and EN 12976-2 standards, at the end of each test day. The final achieved water temperatures of the first configuration are in general higher, than those of the second one, which means a better quality of the delivered energy. Also, the first configuration appears to pick up greater performance, under high solar energy gain (high insolation rate – low thermal losses).

30 August 2022 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
PKPanagiotis Kyriakopoulos
Panagiotis Kyriakopoulos
YCYannis Caouris
Yannis Caouris
Manolis SouliotisManolis Souliotis
Manolis Souliotis
Mst SantamourisMst Santamouris
Mst Santamouris
The urban heat island effect for the coastal Mediterranean city of Kalamata is studied, for June to September during two consecutive years, 2019–2020. Temperature data were gathered by fixed temperature stations, placed in representative locations, covering all the major areas (urban, suburban, and rural). Results showed that the urban area is warmer than suburban and rural ones. The maximum heat island intensity was also estimated, usually achieved during nighttime and early in the morning. As there are no such data for Kalamata, this work helps to identify issues of energy consumption and human comfort. Especially for small Mediterranean cities, the work could be useful for a researcher to clarify the UHI Intensity. Detailed data are presented in the work, both for the clarification of UHI and its intensity and for the characteristics of each area, which could be useful for the development of UHI mitigation strategies, in small coastal cities.