16 April 2012 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
AHA. Haddad
A. Haddad
NHNoureddine Harid
Noureddine Harid
HGH. Griffiths
H. Griffiths
An approach to high field control, particularly in the areas near the high voltage (HV) and ground terminals of an outdoor insulator, is proposed using a nonlinear grading material; Zinc Oxide (ZnO) microvaristors compounded with other polymeric materials to obtain the required properties and allow easy application. The electrical properties of the microvaristor compounds are characterised by a nonlinear field-dependent conductivity. This paper describes the principles of the proposed field-control solution and demonstrates the effectiveness of the proposed approach in controlling the electric field along insulator profiles. A case study is carried out for a typical 11 kV polymeric insulator design to highlight the merits of the grading approach. Analysis of electric potential and field distributions on the insulator surface is described under dry clean and uniformly contaminated surface conditions for both standard and microvaristor-graded insulators. The grading and optimisation principles to allow better performance are investigated to improve the performance of the insulator both under steady state operation and under surge conditions. Furthermore, the dissipated power and associated heat are derived to examine surface heating and losses in the grading regions and for the complete insulator. Preliminary tests on inhouse prototype insulators have confirmed better flashover performance of the proposed graded insulator with a 21 % increase in flashover voltage.

2 March 2021 in IEEE Access
Verified
Journal Article
Open access
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
WRWan Rahiman
Wan Rahiman
SASamir Al-Gailani
Samir Al-Gailani
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
USUsman Ullah Sheikh
Usman Ullah Sheikh
This work aimed to study the influence of contamination profiles and humidity on flashover electrical characteristics of polluted insulators. Firstly, the flashover tests on cap and pin glass insulators under four pollution levels represented by salinity were conducted. Eight artificial contamination profiles based on the solid layer method have been modeled for the selected insulators. The numerical analysis has been used to determine the insulator electrical characteristics such as potential, electric field, and power dissipation under proposed contamination profiles using finite element methods (FEM). Next, the power dissipation has been simulated with consideration of thermal stress propagation in locations with high power. Finally, flashover voltage gradient tests have been conducted under various humidity and contamination profiles. The values of the flashover voltage gradient due to pollution were determined as the percentage of the value of the flashover voltage gradient in the clean condition which was identified as the reference point. The numerical model indicated that the initiation of arc generally occurs at area in which the electric field and power dissipation is maximum. It was also observed from experimental results that the flashover voltage gradient under different contamination profiles has different values depends on the location and dimension of the pollution region.

11 May 2020 in IEEE Access
Verified
Journal Article
Open access
ASAli A. Salem
Ali A. Salem
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
SASamir A. Al-Gailani
Samir A. Al-Gailani
MKM. S. Kamarudin
M. S. Kamarudin
HAHussein Ahmad
Hussein Ahmad
ZSZainal Salam
Zainal Salam
The current paper presents an alternative and innovative technique to predict the severity of pollution of high voltage insulator using a higher harmonics component with up to the 7th component of leakage current. The leakage current was measured using a current transformer and a shunt resistor. Next, laboratory tests were conducted on glass and porcelain insulators with artificial pollution under salt-fog pollution state which is further represented by three levels, namely light, medium, and high contamination. In this case, the formulation of a new severity of harmonic index refers to a ratio of the sum of 5th and 7th to the 3rd harmonic component. More importantly, the new index managed to provide more accurate results when used as a diagnostic tool for the levels of pollution, compared to the ratio of the total harmonic distortion (THD) to the number of odd harmonics components (n) as the boundaries. In this case, the insulators were found to be in a clean and normal condition when the K (5+7)/3 value was greater than 3%. Contrastingly, the insulators were in an extreme condition when the K (5+7)/3 was lower than 3%. Nevertheless, there is a high probability of a flashover in glass and porcelain insulators if the K (5 + 7)/3 value is less than 2%. The present study shows the possibility of utilizing the value of strange harmonics up to the 7th component of leakage current as the parameter for the monitoring of leakage current in overhead insulators in the presence of contamination. Overall, it can be concluded that the 3rd, 5th, and 7th harmonics details extracted from the leakage current act as a good indicator for the level of contamination.

14 January 2022 in IEEE Access
Verified
Journal Article
Open access
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
KLKwan Yiew Lau
Kwan Yiew Lau
WRWan Rahiman
Wan Rahiman
ZAZulkurnain Abdul-Malek
Zulkurnain Abdul-Malek
SASamir Al-Gailani
Samir Al-Gailani
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
Over the past decades, extensive experimental-based research works have been carried out to investigate the flashover phenomenon on the performance of polluted transmission line insulators. The critical focus has been on developing methods that can determine the safety, reliability, and sustainability of the overall power transmission network based on experimental results obtained from polluted insulators’ flashover voltage tests. In this paper, a systematic review of available scientific works, published as early as the 1990s, for the analysis of pollution flashover voltage, is undertaken. The review mainly focuses on factors influencing the efficiency of transmission line insulators under polluted conditions. Specifically, publication databases utilizing various synonyms and keywords associated with the terms “contaminated insulators” and “flashover voltage test” have been scrutinized. The search has resulted in 1364 articles, from which 97 articles have satisfied the review requirements and have been subsequently analyzed to determine the parameters associated with polluted insulators. Major factors that affect the performance of insulators, including electrical and environmental impacts, are discussed. Variations in factors affecting flashover test development and insulator efficiency are also considered. Overall, the current analysis provides an important insight toward successful evaluations of the health of transmission line insulators and research advancements of electric power transmission line insulators.

23 September 2020 in IEEE Access
Verified
Journal Article
Open access
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
SASamir Al-Gailani
Samir Al-Gailani
ZSZainal Salam
Zainal Salam
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
MYMohd Fairouz Mohd Yousof
Mohd Fairouz Mohd Yousof
In this paper, an innovative approach to assess the risk of uniform/non-uniform pollution and wet high voltage glass insulator is proposed. The assessment is based on a new index, named as Rhi, which is derived from the 3rd, 5th and 7th harmonics of the leakage current. Two 33 kV strings of cap and pin glass insulators having three units with different profiles are employed to evaluate the risk level, based on measured critical voltage gradient (Ec). Critical voltage stress tests are executed on the contaminated insulators under different ratios of lower to upper surface (J) and wetting rates. Furthermore, the effects of ratio of soluble deposit density (ESDD) to non-soluble deposit density (NSDD) on the flashover occurrence are analyzed. It was found that the insulator profile has significant influences on the likelihood of flashover which is estimated as 38% and 24% for type A and B insulators, respectively. From the results, it can be concluded that the proposed Rhi index is able to predict the risk level of the insulator and the probability of flashover occurrence more accurately than the 5th/3rd index, which is widely published in literature.

30 September 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
KLKwan Yiew Lau
Kwan Yiew Lau
WRWan Rahiman
Wan Rahiman
SASamir Al-Gailani
Samir Al-Gailani
ZAZulkurnain Abdul-Malek
Zulkurnain Abdul-Malek
USUsman Ullah Sheikh
Usman Ullah Sheikh
Based on experiments and numerical analysis techniques, this paper aims to investigate the influence of the four different coating damage profiles on the performance of coated 33 kV porcelain insulator strings under polluted and clean surface conditions. The performance of the insulators coated with room temperature vulcanizing (RTV) under partial coating damage and undamaged coating was evaluated. The influence of humidity on pollution flashover was taken into consideration. The ring-shaped, fan-shaped, and random-shaped coating was applied following coating damage. The results showed that the flashover characteristic of the RTV-coated insulators had a significant difference as compared to the normal insulators. Electrical characteristics such as the flashover voltage, critical current, and surface resistance were significantly affected by coating damage distribution and humidity level on the insulators’ surface. The electric field and potential difference were analyzed as well using the finite element method (FEM). The initiation of the arc was observed to appear at the area of insulators where the electric field was the highest. It was also observed that different coating distributions of pollution and humidity levels resulted in a change in the surface pollution layer resistance and an uneven distribution of the electric field. This indicates that the coated insulators’ parameters are directly related to the coating damage distribution on the insulator surface, particularly in the presence of humidity.