Salem Mgammal Al-Ameri

Dr. Salem Mgammal Al-Ameri

Department of Power Electrical, Faculty of Electrical and Electronic Engineering, University Tun Hussein Onn Malaysia, 86400, Batu Pahat, Johor, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2021 in IEEE Access
Verified
Journal Article
Open access
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
WRWan Rahiman
Wan Rahiman
SASamir Al-Gailani
Samir Al-Gailani
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
USUsman Ullah Sheikh
Usman Ullah Sheikh
This work aimed to study the influence of contamination profiles and humidity on flashover electrical characteristics of polluted insulators. Firstly, the flashover tests on cap and pin glass insulators under four pollution levels represented by salinity were conducted. Eight artificial contamination profiles based on the solid layer method have been modeled for the selected insulators. The numerical analysis has been used to determine the insulator electrical characteristics such as potential, electric field, and power dissipation under proposed contamination profiles using finite element methods (FEM). Next, the power dissipation has been simulated with consideration of thermal stress propagation in locations with high power. Finally, flashover voltage gradient tests have been conducted under various humidity and contamination profiles. The values of the flashover voltage gradient due to pollution were determined as the percentage of the value of the flashover voltage gradient in the clean condition which was identified as the reference point. The numerical model indicated that the initiation of arc generally occurs at area in which the electric field and power dissipation is maximum. It was also observed from experimental results that the flashover voltage gradient under different contamination profiles has different values depends on the location and dimension of the pollution region.

14 January 2022 in IEEE Access
Verified
Journal Article
Open access
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
KLKwan Yiew Lau
Kwan Yiew Lau
WRWan Rahiman
Wan Rahiman
ZAZulkurnain Abdul-Malek
Zulkurnain Abdul-Malek
SASamir Al-Gailani
Samir Al-Gailani
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
Over the past decades, extensive experimental-based research works have been carried out to investigate the flashover phenomenon on the performance of polluted transmission line insulators. The critical focus has been on developing methods that can determine the safety, reliability, and sustainability of the overall power transmission network based on experimental results obtained from polluted insulators’ flashover voltage tests. In this paper, a systematic review of available scientific works, published as early as the 1990s, for the analysis of pollution flashover voltage, is undertaken. The review mainly focuses on factors influencing the efficiency of transmission line insulators under polluted conditions. Specifically, publication databases utilizing various synonyms and keywords associated with the terms “contaminated insulators” and “flashover voltage test” have been scrutinized. The search has resulted in 1364 articles, from which 97 articles have satisfied the review requirements and have been subsequently analyzed to determine the parameters associated with polluted insulators. Major factors that affect the performance of insulators, including electrical and environmental impacts, are discussed. Variations in factors affecting flashover test development and insulator efficiency are also considered. Overall, the current analysis provides an important insight toward successful evaluations of the health of transmission line insulators and research advancements of electric power transmission line insulators.

30 September 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
KLKwan Yiew Lau
Kwan Yiew Lau
WRWan Rahiman
Wan Rahiman
SASamir Al-Gailani
Samir Al-Gailani
ZAZulkurnain Abdul-Malek
Zulkurnain Abdul-Malek
USUsman Ullah Sheikh
Usman Ullah Sheikh
Based on experiments and numerical analysis techniques, this paper aims to investigate the influence of the four different coating damage profiles on the performance of coated 33 kV porcelain insulator strings under polluted and clean surface conditions. The performance of the insulators coated with room temperature vulcanizing (RTV) under partial coating damage and undamaged coating was evaluated. The influence of humidity on pollution flashover was taken into consideration. The ring-shaped, fan-shaped, and random-shaped coating was applied following coating damage. The results showed that the flashover characteristic of the RTV-coated insulators had a significant difference as compared to the normal insulators. Electrical characteristics such as the flashover voltage, critical current, and surface resistance were significantly affected by coating damage distribution and humidity level on the insulators’ surface. The electric field and potential difference were analyzed as well using the finite element method (FEM). The initiation of the arc was observed to appear at the area of insulators where the electric field was the highest. It was also observed that different coating distributions of pollution and humidity levels resulted in a change in the surface pollution layer resistance and an uneven distribution of the electric field. This indicates that the coated insulators’ parameters are directly related to the coating damage distribution on the insulator surface, particularly in the presence of humidity.

3 May 2021 in IEEE Access
Verified
Journal Article
Open access
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
MYMohd Fairouz Mohd Yousof
Mohd Fairouz Mohd Yousof
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
FBFahd A. Banakhr
Fahd A. Banakhr
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
Frequency Response Analysis (FRA) is the most reliable technique currently used to evaluate the mechanical integrity of power transformers. While the measurement devices have been well developed over the past two decades, interpretation of the FRA signatures is still challenging regardless of the several papers published in this regard. This paper adds an attempt to understand the power transformer FRA signatures through experimental and simulation analyses. In this context, experimental FRA measurements are conducted on a 33/11 kV, 30 MVA transformer under various faults, including winding deformation, the short circuit turns, loss of clamping, and bushing fault. At the same time, the high-frequency transformer model that comprises series capacitance, self-inductance, series resistance, and mutual inductance is simulated using MATLAB / Simulink to compare simulation and experimental results. The correlation between physical circuit parameters and various faults facilitates a better understanding of each fault’s effect on the FRA signature. To quantify the impact of such faults, correlation coefficient, the absolute sum of logarithmic error, standard deviation, and sum square error are calculated with respect to the healthy signature at three frequency regions. Results show that using statistical coefficients over three frequency ranges of the FRA signature facilitates better fault identification and quantification.

25 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
MYMohd Fairouz Mohd Yousof
Mohd Fairouz Mohd Yousof
ASAli Salem
Ali Salem
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
Frequency response analysis (FRA) is a method of monitoring a power transformer’s mechanical integrity. However, identifying the type of fault and its severity by comparing measured responses is still challenging and mostly relies on personnel expertise. This paper is taking one step forward to standardize the FRA interpretation process by proposing guidelines based on various international standards and FRA case studies. In this study, the FRA signature is divided into three regions: low-, mid- and high-frequency regions. The deviation from the fingerprint signature for various faults is classified into small, large, and no variations, based on the calculation of the correlation coefficient. The proposed guidelines are developed based on the frequency regions, and the level of variation is represented using a simple arrow method to simplify the interpretation process. A case study is conducted on a three-phase 11/0.433 kV, 500 kVA distribution transformer with a short circuit winding fault to validate the proposed guidelines.

18 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
KLKwan Yiew Lau
Kwan Yiew Lau
ZAZulkurnain Abdul-Malek
Zulkurnain Abdul-Malek
WZWenbin Zhou
Wenbin Zhou
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
In this paper, a unique approach based on electrical characteristics observed from measurements of contaminated polymeric insulators was established to calculate the electric field distribution over their surfaces. A case study using two different 33 kV polymeric insulator geometric profiles was performed to highlight the benefits of the proposed modeling approach. The conductance of the pollution layer was tested to establish a nonlinear field-dependent conductivity for pollution modeling. The leakage current (LC) of the polluted insulator was measured in a laboratory under clean and wet conditions. Then, using the finite element method (FEM), the electric field and current density distributions along the insulator were computed. The results showed that the insulators experienced an increase in the electric field (EF) magnitude ranging from 0.3 kV/cm to 3.6 kV/cm for the insulator with similar sheds (type I) and 2.2–4.5 kV/cm for the insulator with alternating sheds (big and small, type II) under the high rain condition with a flow rate of 9 L/h. Meanwhile, the highest electric field under fog was 1.74 kV/cm for the insulator with similar sheds and 2.32 kV/cm for an insulator with alternating sheds. Due to the larger diameter on the big shed and the longer leakage distance on the insulator with alternating sheds, the EF on the insulator with alternating sheds is higher than the EF on the insulator with similar sheds. The proposed modeling and simulation provided a detailed field condition estimation around the insulators. This is critical for forecasting the emergence of dry bands and the commencement of flashover on the surfaces of the insulators.