Luigi Sabatini

Dr. Luigi Sabatini

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Orthopaedics
Verified
Journal Article
Closed access
ABAlessandro Bistolfi
Alessandro Bistolfi
FGFortunato Giustra
Fortunato Giustra
Francesco BoscoFrancesco Bosco
Francesco Bosco
LSLuigi Sabatini
Luigi Sabatini
AAAlessandro Aprato
Alessandro Aprato
ABAnuj Bellare
Anuj Bellare

1 April 2016 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
AAAlessandro Aprato
Alessandro Aprato
SRSalvatore Risitano
Salvatore Risitano
LSLuigi Sabatini
Luigi Sabatini
MGMatteo Giachino
Matteo Giachino
GAGabriele Agati
Gabriele Agati
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Interest for uncemented total knee arthroplasty (TKA) has greatly increased in recent years. This technique, less used than cemented knee replacement in the last decades, sees a revival thanks an advance in prosthetic design, instrumentation and operative technique. The related literature in some cases shows conflicting data on survival and on the revision’s rate, but in most cases a success rate comparable to cemented TKA is reported. The optimal fixation in TKA is a subject of debate with the majority of surgeons favouring cemented fixation.

1 January 2018 in Clinical Medicine Insights: Arthritis and Musculoskeletal Disorders
Verified
Journal Article
Open access
LSLuigi Sabatini
Luigi Sabatini
SRSalvatore Risitano
Salvatore Risitano
GPGennaro Parisi
Gennaro Parisi
FTFerdinando Tosto
Ferdinando Tosto
Pier Francesco IndelliPier Francesco Indelli
Pier Francesco Indelli
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Background: Traditional total knee implants designs, usually, are not able to reproduce the physiological kinematics of the knee, leaving almost 20% of the patients, those who underwent a total knee arthroplasty (TKA), not fully satisfied. Modern inserts are nowadays designed with a fully congruent medial compartment to reproduce the normal medial pivoting biomechanics of the knee. The aim of this article was to evaluate preliminary clinical improvement using the Medial Congruent (MC) insert as specific level of constraint. Materials and methods: A total of 10 consecutive patients have been enrolled in this study and treated using an MC tibial polyethylene insert. The Oxford Knee Score (OKS) and the Knee Society Score (KSS) have been assessed preoperatively and at 3-month, 6-month, and 1-year follow-up (FU) and used as validated measurements to evaluate early clinical improvements. Postoperative radiological examination was reviewed looking for radiolucent lines or loosening of the components. Results: Average improvement in OKS was from 19.5 to 41.2, whereas KSS improved with an average score from 64.7 preoperatively to 167.5 at the final FU showing good to excellent results in 95% of the treated knees. Evaluating the range of motion, the average maximum active movement was 124° and none of the patients needing for a revision surgery or manipulation under anesthesia. No complications were observed at the final FU as septic or aseptic loosening or vascular or neurologic injury. Discussion and conclusions: Medial Congruent insert showed good to excellent clinical results at 1-year FU. Range of motion and subjective outcomes were satisfying and comparable with results obtained in literature using traditional TKA design.

29 October 2022 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
Francesco BoscoFrancesco Bosco
Francesco Bosco
FGFortunato Giustra
Fortunato Giustra
RVRiccardo Giai Via
Riccardo Giai Via
ALAlessandro Dario Lavia
Alessandro Dario Lavia
MCMarcello Capella
Marcello Capella
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Purpose: This study aims to examine the clinical and radiological outcomes of patients who underwent ACL reconstruction (ACLR) combined with anterior closed-wedge high tibial osteotomy (ACW-HTO) for posterior tibial slope (PTS) reduction to investigate the efficacy of this procedure in improving anterior knee stability and preventing graft failure in primary and revision ACLR. Methods: A literature search was conducted in six databases (PubMed, Embase, Medline, Web of Science, Cochrane, and Scopus). The study was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. The initial screening identified 1246 studies. Each eligible clinical article was screened according to the Oxford Centre for Evidence-Based Medicine 2011 levels of evidence (LoE), excluding clinical studies of LoE V. Quality assessment of the articles was performed using the ROBINS-I methodological evaluation. This systematic review and meta-analysis was registered on the International Prospective Register of Systematic Reviews (PROSPERO). For the outcomes that were possible to perform a meta-analysis, a p < 0.05 was considered statistically significant. Results: Five clinical studies were included in the final analysis. A total of 110 patients were examined. Pre- and post-operative clinical and objective tests that assess anteroposterior knee stability, PTS, clinical scores, and data on surgical characteristics, complications, return to sports activity, and graft failure after ACLR were investigated. A meta-analysis was conducted using R software, version 4.1.3 (2022, R Core Team), for Lysholm score and PTS outcomes. A statistically significant improvement for both these clinical and radiological outcomes (p < 0.05) after the ACW-HTO surgical procedure was found. Conclusion: ACLR combined with ACW-HTO restores knee stability and function with satisfactory clinical and radiological outcomes in patients with an anterior cruciate ligament injury associated with a high PTS and seems to have a protective effect from further ruptures on the reconstructed ACL. Level of evidence: Level IV.

2 July 2022 in Journal of Orthopaedics
Verified
Journal Article
Closed access
SRSalvatore Risitano
Salvatore Risitano
GCGiorgio Cacciola
Giorgio Cacciola
LSLuigi Sabatini
Luigi Sabatini
MCMarcello Capella
Marcello Capella
Francesco BoscoFrancesco Bosco
Francesco Bosco
Raju VaishyaRaju Vaishya
Raju Vaishya

16 May 2012 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
LSLuigi Sabatini
Luigi Sabatini
ATAndrea Trecci
Andrea Trecci
DIDaniele Imarisio
Daniele Imarisio
MUMarco Davide Uslenghi
Marco Davide Uslenghi
GBGiuseppe Bianco
Giuseppe Bianco
RSRoberto Scagnelli
Roberto Scagnelli
Background Blood transfusion is often required in total knee replacement; various methods of blood preservation have been studied. The best solution is to reduce the loss of blood during and after surgery. Materials and methods We designed this study to evaluate the hemostatic efficacy and safety of fibrin tissue adhesive (Quixil) in patients receiving total knee arthroplasty [low contact stress (LCS, DePuy, Warsaw, IN, US) cementless total knee replacement (TKR)] with a prospective, randomized, standard treatment controlled study. Thirty-five patients were randomized to receive treatment with fibrin tissue adhesive (treatment group), and 35 were randomized to be managed with postoperative blood recovery and reinfusion (control group). Blood loss in suction drain, decrease in hemoglobin values, and transfusions were recorded. Results A significant reduction in apparent total blood loss was detected in the treatment group compared with the control group. There was also a lower decrease in hemoglobin level, although this difference was not significant. When fibrin tissue adhesive was administered, the need for transfusions was lower. No major adverse events were recorded in our series. Conclusions Fibrin tissue adhesive reduced blood loss in TKR and seemed to significantly reduce the need for blood transfusion. Fibrin tissue adhesive can be an appropriate solution to enhance hemostasis and vessel sealing at the operative site in TKR, in order to reduce blood loss after surgery and the risk of complications.