Salvatore Risitano

Dr. Salvatore Risitano

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Clinical Orthopaedics and Trauma
Verified
Journal Article
Closed access
GPGennaro Pipino
Gennaro Pipino
SRSalvatore Risitano
Salvatore Risitano
Francesco AlvianoFrancesco Alviano
Francesco Alviano
EWEdward J. Wu
Edward J. Wu
LBLaura Bonsi
Laura Bonsi
Pier Francesco IndelliPier Francesco Indelli
Pier Francesco Indelli

29 October 2022 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
Francesco BoscoFrancesco Bosco
Francesco Bosco
FGFortunato Giustra
Fortunato Giustra
RVRiccardo Giai Via
Riccardo Giai Via
ALAlessandro Dario Lavia
Alessandro Dario Lavia
MCMarcello Capella
Marcello Capella
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Purpose: This study aims to examine the clinical and radiological outcomes of patients who underwent ACL reconstruction (ACLR) combined with anterior closed-wedge high tibial osteotomy (ACW-HTO) for posterior tibial slope (PTS) reduction to investigate the efficacy of this procedure in improving anterior knee stability and preventing graft failure in primary and revision ACLR. Methods: A literature search was conducted in six databases (PubMed, Embase, Medline, Web of Science, Cochrane, and Scopus). The study was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. The initial screening identified 1246 studies. Each eligible clinical article was screened according to the Oxford Centre for Evidence-Based Medicine 2011 levels of evidence (LoE), excluding clinical studies of LoE V. Quality assessment of the articles was performed using the ROBINS-I methodological evaluation. This systematic review and meta-analysis was registered on the International Prospective Register of Systematic Reviews (PROSPERO). For the outcomes that were possible to perform a meta-analysis, a p < 0.05 was considered statistically significant. Results: Five clinical studies were included in the final analysis. A total of 110 patients were examined. Pre- and post-operative clinical and objective tests that assess anteroposterior knee stability, PTS, clinical scores, and data on surgical characteristics, complications, return to sports activity, and graft failure after ACLR were investigated. A meta-analysis was conducted using R software, version 4.1.3 (2022, R Core Team), for Lysholm score and PTS outcomes. A statistically significant improvement for both these clinical and radiological outcomes (p < 0.05) after the ACW-HTO surgical procedure was found. Conclusion: ACLR combined with ACW-HTO restores knee stability and function with satisfactory clinical and radiological outcomes in patients with an anterior cruciate ligament injury associated with a high PTS and seems to have a protective effect from further ruptures on the reconstructed ACL. Level of evidence: Level IV.

2 July 2022 in Journal of Orthopaedics
Verified
Journal Article
Closed access
SRSalvatore Risitano
Salvatore Risitano
GCGiorgio Cacciola
Giorgio Cacciola
LSLuigi Sabatini
Luigi Sabatini
MCMarcello Capella
Marcello Capella
Francesco BoscoFrancesco Bosco
Francesco Bosco
Raju VaishyaRaju Vaishya
Raju Vaishya

1 August 2017 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
SRSalvatore Risitano
Salvatore Risitano
Pier Francesco IndelliPier Francesco Indelli
Pier Francesco Indelli
A rectangular and symmetrical gap in flexion as well as in extension is mandatory to achieve good outcomes and good long-term results in total knee arthroplasty (TKA) using classical designs. Recently, as showed in several fluoroscopic studies, different modern designs (medial congruent or sagittally stable implants) have been demonstrated to better reproduce the more physiological medial pivoting (MP) biomechanics of the normal knee when compared to classical postero-stabilized (PS) and cruciate-retaining (CR) designs. These modern designs, characterized by different level of conformity, might require adopting a different surgical technique in terms of soft tissue balancing technique for primary TKA. In such cases, the current authors suggest to reproduce a slightly asymmetric extension and flexion gaps with a tighter medial then lateral compartment to re-establish the MP kinematics of the normal knee.

5 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FGFortunato Giustra
Fortunato Giustra
Francesco BoscoFrancesco Bosco
Francesco Bosco
GCGiorgio Cacciola
Giorgio Cacciola
SRSalvatore Risitano
Salvatore Risitano
MCMarcello Capella
Marcello Capella
LSLuigi Sabatini
Luigi Sabatini
In the last decades, several surgical techniques, such as medial pivot (MP) philosophy and kinematic alignment (KA), have been introduced in total knee arthroplasty (TKA) to improve patients’ outcomes. This retrospective study aims to evaluate the clinical, radiographic, and functional results of PCL preservation or sacrifice in KA MP-TKA. A consecutive series of 147 patients older than 60, with a minimum follow-up of two years, were treated with TKA for severe primary knee osteoarthritis (OA) at the Department of Orthopedics and Traumatology between 1 January 2019, and 1 July 2020. After excluding those not meeting the inclusion criteria, 64 patients were included in the study analysis. Regarding radiographic outcomes, no statistically significant difference was observed between patients with preserved or sacrificed PCL (p > 0.05). A slight improvement in Knee Society Score (KSS), knee and function score, and FJS was observed for the PCL-preserved group, although this superiority tendency was not statistically significant (p > 0.05). PCL-preserved MA MP-TKA reported a statistically significant result in only two questions on the FJS questionnaire (p < 0.05). A slight, non-statistically significant improvement in active ROM was found in the PCL-sacrificed group (p > 0.05). No interventions or revisions were reported in this case series for all treated patients at the final follow-up. No significant differences were described in clinical, radiographic, and functional outcomes in preserved or sacrificed PCL KA MP-TKA. Although not significant, a slight trend toward better clinical outcomes was reported in PCL-preserved KA MP-TKA.

1 March 2017 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
LSLuigi Sabatini
Luigi Sabatini
SRSalvatore Risitano
Salvatore Risitano
LRLorenzo Rissolio
Lorenzo Rissolio
ABAndrea Bonani
Andrea Bonani
FAFrancesco Atzori
Francesco Atzori
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Background: Constrained condylar knee (CCK) prosthesis are common used for revision surgery but can also help surgeons to improve implant stability in primary knee arthroplasty, in fact in severe knee arthrosis with serious deformity associated with a significant instability a more constrained articulation is required. With introduction of second generation of semi-constrained prosthesis, rate of complication is real decreased and a good survival rate and functional score results is showed. In this paper we write about our experience using CCK in primary knee arthroplasty. Methods: Between January 2012 and December 2015, 28 second-generation semi-constrained knee arthroplasties were performed as a first implant. Two different types of implants were used: 10 constrained condylar knee (CCK Zimmer) and 18 TC3 (DePuy Johnson & Johnson). All patients were over 75 years old (mean 81.75) with a severe deformity and clinical evaluations at 2-, 6-, 12-month after surgery and every year performed. X-rays at 6, 12 months and then annually was planned with an average follow-up of 31.28 (range 6–48) months. Results: No patients were lost during the follow-up. The mean functional knee society score (KSS) improved from 30 points preoperatively to 92.1 points at the last follow-up. All patients recovered full extension during follow-up and no radiolucent lines were showed at X-ray control. There were no deep infections or peri-prosthetic fractures. Conclusions: Second generation semi-constrained knee prosthesis represent safe and practical treatment in primary total knee arthroplasty (TKA) in case of severe deformity that can’t be managed with accurate soft tissue release, especially in elderly patients.