Petr Henyš

Prof. Petr Henyš

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Burns
Verified
Journal Article
Closed access
LČLukáš Čapek
Lukáš Čapek
CFCormac Flynn
Cormac Flynn
MMMartin Molitor
Martin Molitor
SCSimon Chong
Simon Chong
PHPetr Henyš
Petr Henyš

1 November 2019 in European Journal of Mechanics - A/Solids
Verified
Journal Article
Closed access
PHPetr Henyš
Petr Henyš
LČLukáš Čapek
Lukáš Čapek
JBJan Březina
Jan Březina

17 November 2015 in Osteoporosis International
Verified
Journal Article
Closed access
PDF file
FTFulvia Taddei
Fulvia Taddei
CFC. Falcinelli
C. Falcinelli
LBL. Balistreri
L. Balistreri
PHPetr Henyš
Petr Henyš
FBFabio Baruffaldi
Fabio Baruffaldi
ESEnrico Schileo
Enrico Schileo

1 January 2015 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PHPetr Henyš
Petr Henyš
LČLukáš Čapek
Lukáš Čapek
JFJaroslav Fencl
Jaroslav Fencl
EPEgon Prochazka
Egon Prochazka
The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of dislocation failure is highest in the first year after arthroplasty implantation. The aim of the study was to quantitatively evaluate the implant-bone stability of a cementless acetabular cup prosthesis by using a device based on resonance frequency analysis. The evaluation of this device was done by finite element analysis and in vitro experiments. It was shown that not all the resonance frequencies can be measured by our device. The resonance frequencies vary within the range of 500–3000 Hz. The proposed power spectrum measurement gives the information about the absolute stiffness of the press-fit implant.

4 August 2023 in Science Advances
Verified
Journal Article
Open access
MLMarcos Gonzalez Lopez
Marcos Gonzalez Lopez
BHBarbora Huteckova
Barbora Huteckova
JLJosef Lavicky
Josef Lavicky
NZNikodem Zezula
Nikodem Zezula
VRVladislav Rakultsev
Vladislav Rakultsev
JKJan Krivanek
Jan Krivanek
Mineralized tissues, such as bones or teeth, are essential structures of all vertebrates. They enable rapid movement, protection, and food processing, in addition to providing physiological functions. Although the development, regeneration, and pathogenesis of teeth and bones have been intensely studied, there is currently no tool to accurately follow the dynamics of growth and healing of these vital tissues in space and time. Here, we present the BEE-ST (Bones and tEEth Spatio-Temporal growth monitoring) approach, which allows precise quantification of development, regeneration, remodeling, and healing in any type of calcified tissue across different species. Using mouse teeth as model the turnover rate of continuously growing incisors was quantified, and role of hard/soft diet on molar root growth was shown. Furthermore, the dynamics of bones and teeth growth in lizards, frogs, birds, and zebrafish was uncovered. This approach represents an effective, highly reproducible, and versatile tool that opens up diverse possibilities in developmental biology, bone and tooth healing, tissue engineering, and disease modeling.

29 July 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
QGQuentin Goossens
Quentin Goossens
SLSteven Leuridan
Steven Leuridan
PHPetr Henyš
Petr Henyš
JRJorg Roosen
Jorg Roosen
LPLeonard Cezar Pastrav
Leonard Cezar Pastrav
JSJos Vander Sloten
Jos Vander Sloten
In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion.