For heritage buildings, energy-efficient retrofitting cannot be applied with the same range of possibilities as with existing buildings. Applying such improvements to heritage buildings can be challenging due to their historic and/or cultural significance and non-standard construction methods. This paper reviews the technical challenges and potential of applying energy efficient retrofit elements in heritage buildings. The retrofitting measures reviewed are draught-proofing, windows, insulation, ventilation, heating, solar photovoltaics and phase change materials. It is possible to significantly reduce energy use in heritage buildings with such retrofits. However, there is no universal way to apply energy-efficient retrofitting in heritage buildings, which is apparent in the literature, where case studies are prevalent.
The advancements in sensor and communication technologies drive the rapid developments in the applications of occupancy and indoor environmental monitoring in buildings. Currently, the installation standards for sensors are scarce and the recommendations for sensor positionings are very general. However, inadequate sensor positioning might diminish the reliability of sensor data, which could have serious impacts on the intended applications such as the performance of demand-controlled HVAC systems and their energy use. Thus, there is a need to understand how sensor positioning may affect the sensor data, specifically when using multi-sensor devices in which several sensors are being bundled together. This study is based on the data collected from 18 multi-sensor devices installed in three single-occupant offices (six sensors in each office). Each multi-sensor device included sensors to measure passive infrared (PIR) radiation, temperature, CO2, humidity, and illuminance. The results show that the positions of PIR and CO2 sensors significantly affect the reliability of occupancy detection. The typical approach of positioning the sensors on the ceiling, in the middle of offices, may lead to relatively unreliable data. In this case, the PIR sensor in that position has only 60% accuracy of presence detection. Installing the sensors under office desks could increase the accuracy of presence detection to 84%. These two sensor positions are highlighted in sensor fusion analysis as they could reach the highest accuracy compared to other pairs of PIR sensors. Moreover, sensor positioning can affect various indoor environmental parameters, especially temperature and illuminance measurements.
Inclusion of energy efficiency measures (EEMs) in the renovation of the single-family housing stock can unlock the potential for much-needed energy efficiency to tackle climate change. Energy renovation (ER) in single-family houses is often promoted as an aggregate process, and EEMs are treated homogenously without sufficient attention to their differences. This study applies a comparative analysis on common EEMs using chi-square test to investigate the influence of factors already found affecting the implementation of ER. This paper addresses the “personal” and “house-related” factors influencing the adoption of EEMs regardless of motives or barriers leading the adopters’ decisions. This strategy is useful to highlight the contexts leading to an increase in the adoption rate of different EEMs. The analysis is based on a questionnaire survey mailed in spring 2017 to 1550 single-family homeowners in the northern region of Sweden. Approximately 60% of respondents showed interest in adopting at least one EEM if they implement a major renovation. About 46% of respondents stated to have at least one indoor environmental problem (IEP) in their houses, and IEPs are found to have significant relations with homeowners’ interest to adopt several different EEMs. The policy implications related to different EEMs are discussed.
Positive energy district (PED) is a novel idea aimed to have an annual surplus of renewable energy and net zero greenhouse gas emissions within an area. However, it is still an ambiguous concept, which might be due to the complexity of city district projects with interconnected infrastructures and numerous stakeholders involved. This study discusses various aspects of PED implementation and presents practitioners’ experiences with the PED concept, challenges, and facilitators they have faced with real projects. The study is based on interviews with ten Swedish professionals. The major challenges reported for PED implementation were local energy production and energy flexibility, sub-optimization, legislation, suitable system boundaries, and involvement of stakeholders. Most of the interviewees mentioned improved collaboration, integrated innovative technology, political support, and climate change mitigation goals as important facilitators. The interviewees highlighted the importance of a local perspective and considered each city’s preconditions when developing a PED project. The study emphasizes that to facilitate PED implementation and replication in cities, more knowledge and clarity is required about PED such as on the definition and system boundaries.
In Sweden, all new buildings need to comply with the National Board of Housing, Building and Planning’s requirement on specific purchased energy (kWh/m2). Accordingly, this indicator is often used to set design criteria in the building procurement process. However, when energy use is measured in finished buildings, the measurements often deviate significantly from the design calculations. The measured specific purchased energy does not necessarily reflect the responsibility of the building contractor, as it is influenced by the building operation, user behavior and climate. Therefore, Swedish building practitioners may prefer other indicators for setting design criteria in the building procurement process. The aim of this study was twofold: (i) to understand the Swedish building practitioners’ perspectives and opinions on seven building energy performance indicators (envelope air leakage, U-values for different building parts, average U-value, specific heat loss, heat loss coefficient, specific net energy, and specific purchased energy); and (ii) to understand the consequences for the energy performance of multi-family buildings of using the studied indicators to set criteria in the procurement process. The study involved a Delphi approach and simulations of a multi-family case study building. The studied indicators were discussed in terms of how they may meet the needs of the building practitioners when used to set building energy performance criteria in the procurement process.
From 1st January 2022, Swedish government plan to introduce the climate declarations as a legal requirement for new buildings. LCA is a method that could be used to quantify buildings’ climate impact. The climate declaration in the Swedish building code expects to create interest in LCA among stakeholders. This study aims to identify and understand the challenges and opportunities of using LCA by stakeholders during the early stage of construction process. The study is based on responses from six building professionals to a questionnaire. The policy implications of the study findings are discussed.