Carlos Aroso

Prof. Carlos Aroso

CESPU, Instituto de Investigação e Formação Avançada em Ciências e Tecnologias da Saúde, Rua Central de Gandra, 1317, 4585-116 Gandra PRD, Portugal
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
AVANA Sofia VINHAS
ANA Sofia VINHAS
Carlos ArosoCarlos Aroso
Carlos Aroso
FSFilomena Salazar
Filomena Salazar
PLPaula López-Jarana
Paula López-Jarana
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Introduction: Different implant–abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant–abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant–abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment–implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.

14 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
AVANA Sofia VINHAS
ANA Sofia VINHAS
Carlos ArosoCarlos Aroso
Carlos Aroso
FSFilomena Salazar
Filomena Salazar
MRMarta Relvas
Marta Relvas
Ana Cristina BragaAna Cristina Braga
Ana Cristina Braga
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
The stability and integrity of the abutment-implant connection, by means of a screw, is fallible from the moment the prosthetic elements are joined and is dependent on the applied preload, wear of the components and function. One of the main causes of screw loosening is the loss of preload. The loosening of the screw-abutment can cause complications such as screw fracture, marginal gap, peri-implantitis, bacterial microleakage, loosening of the crown and discomfort of the patient. It is also reported that loosening of the screw/abutment may lead to a failure of osseointegration. It is necessary to evaluate and quantify, with in vitro studies, the torque loss before and after loading in the different connections. Aim: evaluate the influence of implant- abutment connection design in torque maintenance after single tightening, multiple tightening and multiple tightening followed by mechanical cycling. Materials and Methods: 180 Klockner implants divided in 4 groups: 15 SK2 external connection, 25 Ncm tightening torque; 15 KL external connection, 30 Ncm tightening torque; 15 Vega internal connection, 25 Ncm tightening torque; 15 Essential internal connection, 30 Ncm tightening torque. In each group removal torque values (RTV) were evaluated with a digital torque meter, in 3 distinct phases: after one single tightening, 10 multiple tightenings and 10 multiple tightenings and cyclic loading (500 N × 1000 cycles). Results: After one single tightening, and for all connections, RTV were lower than those of insertion, but only for Essential and Vega internal connections this result was statistically significant. After multiple tightening, RTV were significantly lower in all connections. After repeated tightening followed by cyclic loading, mean RTV were significantly lower, when compared to insertion torque. The multiple tightening technique resulted in higher RTV than the single tightening technique, except for Vega implant. The multiple tightening followed by cyclic load, compared to the other phases, was the one that generated the lowest RTV, for all connections. Conclusions: The connection design, in our study, did not seem to influence the maintenance of preload. Loading influenced the loss of preload, in the sense that significantly decreased the removal torque values. The multiple re-tightening technique resulted in higher removal torque values than the single tightening technique. Clinically, our results recommend to retighten retaining screws, a few minutes after insertion.

11 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
ACAurora Carvalho
Aurora Carvalho
Pedro BarreirosPedro Barreiros
Pedro Barreiros
JSJuliana de Sá
Juliana de Sá
Carlos ArosoCarlos Aroso
Carlos Aroso
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.

1 November 2020 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
JSJuliana De Sá
Juliana De Sá
FVFrancisca Vieira
Francisca Vieira
Carlos ArosoCarlos Aroso
Carlos Aroso
MCMónica Guedes Cardoso
Mónica Guedes Cardoso
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
Aim and Background. The absorption of fluids by denture base materials diminishes the mechanical properties such as hardness, strength, and fatigue limit due to the plasticizing effect of water. This study aimed to evaluate the influence of oral pH on the fracture resistance of prosthetic bases made of three different heat-polymerizable acrylic resin brands: RS Vertex®, Triplex Hot®, and Megacryl®. The strength needed to fracture the resins and the resistance to fracture each resin were evaluated. Methods. Ten prosthesis bases prepared with each brand of resin were subjected to neutral and low pH conditions (pH 7 and pH 4) by submerging them in artificial saliva for 30 days. After exposure, the fatigue resistance of the resins was tested using a Dental CS® Testing Machine. Statistical Analysis Test. The data sets were described quantitatively in terms of mean (M) and standard deviation (SD). Shapiro–Wilk tests and unilateral analysis of variance (ANOVA) were performed and complemented by Tukey’s multiple comparison tests. The effect size (η2), whose cohort points followed Cohen’s recommendations: 0.01 (low), 0.06 (medium), and 0.14 (high), was calculated. The results were considered significant if p < 0.05 and marginally significant if p < 0.10 . Results. One-way ANOVA showed that Megacryl® had the highest fracture resistance at pH 7 (52.23 Kgf), compared with Triplex Hot® ( p < 0.001 ) and RS Vertex® ( p = 0.034 ). Two-way ANOVA confirmed the interaction between brand and pH ( p = 0.022 ), also revealing that brands comparison is significant or marginally significant, when pH is not considered (Megacryl® versus Triplex Hot®, p < 0.001 , and RS Vertex®, p = 0.058 ; Triplex Hot® versus RS Vertex®, p = 0.051 ), and pH 7 results were significantly higher ( p = 0.003 ), even when brands are not considered. Hence, Megacryl® at pH 7 was found to have the highest fracture resistance, detached from other brands and pH values. Conclusion. It can be concluded within the limitations of this study that there are differences in the fracture resistance among the three brands of acrylic resin. Megacryl® was found to have the highest fracture resistance, and Triplex Hot® was the lowest. The results also show that exposure to a low pH environment decreases the fracture resistance of the Megacryl® and RS Vertex® resins.

9 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
ARAna María Rodríguez-Ces
Ana María Rodríguez-Ces
Óscar Rapado-GonzálezÓscar Rapado-González
Óscar Rapado-González
ASAngel Salgado-Barreira
Angel Salgado-Barreira
MSMaría Arminda Santos
María Arminda Santos
Carlos ArosoCarlos Aroso
Carlos Aroso
Maria Mercedes Suarez-CunqueiroMaria Mercedes Suarez-Cunqueiro
Maria Mercedes Suarez-Cunqueiro
Liquid biopsies have been identified as a viable source of cancer biomarkers. We aim to evaluate the diagnostic accuracy of cell-free DNA integrity (cfDI) in liquid biopsies for cancer. A comprehensive literature search was conducted through PubMed, Embase, Web of Science, and Cochrane Library up to June 2024. Seventy-two study units from forty-six studies, comprising 4286 cancer patients, were identified and evaluated. The Quality Assessment for Studies of Diagnostic Accuracy-2 (QUADAS-2) was used to assess study quality. Meta-regression analysis was employed to investigate the underlying factors contributing to heterogeneity, alongside an evaluation of publication bias. The bivariate random-effect model was utilized to compute the primary diagnostic outcomes and their corresponding 95% confidence intervals (CIs). The pooled sensitivity, specificity, and positive and negative likelihood ratios of cfDI in cancer diagnosis were 0.70 and 0.77, 3.26 and 0.34, respectively. The overall area under the curve was 0.84, with a diagnostic odds ratio of 10.63. This meta-analysis suggested that the cfDI index has a promising potential as a non-invasive and accurate diagnostic tool for cancer. Study registration: The study was registered at PROSPERO (reference No. CRD42021276290).

1 January 2016 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
Carlos ArosoCarlos Aroso
Carlos Aroso
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
RURaul Ustrell
Raul Ustrell
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Ana Cristina BragaAna Cristina Braga
Ana Cristina Braga
TETomas Escuin
Tomas Escuin
Aroso C, et al. J Adv Prosthodont. 2016 Feb;8(1):21-29. http://dx.doi.org/10.4047/jap.2016.8.1.21