José Vicente Ríos-Santos

Prof. José Vicente Ríos-Santos

Universidad de Sevilla (SPAIN), School of Denttistry
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2004 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
AJA. Jiménez‐Pinzón
A. Jiménez‐Pinzón
Juan Segura-EgeaJuan Segura-Egea
Juan Segura-Egea
MPM. Poyato‐Ferrera
M. Poyato‐Ferrera
Eugenio Velasco-OrtegaEugenio Velasco-Ortega
Eugenio Velasco-Ortega
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos

1 July 2004 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
Juan Segura-EgeaJuan Segura-Egea
Juan Segura-Egea
AJA. Jiménez‐Pinzón
A. Jiménez‐Pinzón
MPM. Poyato‐Ferrera
M. Poyato‐Ferrera
Eugenio Velasco-OrtegaEugenio Velasco-Ortega
Eugenio Velasco-Ortega
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos

11 July 2005 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
Juan Segura-EgeaJuan Segura-Egea
Juan Segura-Egea
AJA. Jiménez‐Pinzón
A. Jiménez‐Pinzón
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Eugenio Velasco-OrtegaEugenio Velasco-Ortega
Eugenio Velasco-Ortega
RCR. Cisneros‐Cabello
R. Cisneros‐Cabello
MPM. Poyato‐Ferrera
M. Poyato‐Ferrera

25 March 2019 in Materials
Verified
Journal Article
Open access
PDF file
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
ERElisa Rios-Carrasco
Elisa Rios-Carrasco
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Roman PerezRoman Perez
Roman Perez
Javier GilJavier Gil
Javier Gil
The load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption. We propose the use of low-modulus β-type titanium alloys that can improve the growth of new bone surrounding the implant. We designed dental implants with identical morphology and micro-roughness composed of: Ti-15Zr, Ti-19.1Nb-8.8Zr, Ti-41.2Nb-6.1Zr, and Ti-25Hf-25Ta. The commercially pure Ti cp and Ti-6Al-4V were used as control samples. The alloys were initially mechanically characterized with a tensile test using a universal testing machine. The results showed the lowest elastic modulus for the Ti-25Hf-25Ta alloy. We implanted a total of six implants in the mandible (3) and maxilla (3) for each titanium alloy in six minipigs and evaluated their bone index contact (i.e., the percentage of new bone in contact with the metal—BIC%) after 3 and 6 weeks of implantation. The results showed higher BIC% for the dental implants with lowest elastic modulus, showing the importance of decreasing the elastic modulus of alloys for the successful osseointegration of dental implants.

AVANA Sofia VINHAS
ANA Sofia VINHAS
Carlos ArosoCarlos Aroso
Carlos Aroso
FSFilomena Salazar
Filomena Salazar
PLPaula López-Jarana
Paula López-Jarana
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Introduction: Different implant–abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant–abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant–abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment–implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.

Simone MarquesSimone Marques
Simone Marques
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
CFCarlos Falcão
Carlos Falcão
Bernardo Ferreira de LemosBernardo Ferreira de Lemos
Bernardo Ferreira de Lemos
BRBlanca Ríos-Carrasco
Blanca Ríos-Carrasco
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Introduction. Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. Aim. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques. Materials and methods. A Medline, PubMed and EBSCO Host databases search, complemented by a hand search, was performed in order to select relevant reports regarding the appliance of digital impressions in implant dentistry. The search subject included but was not limited to accuracy of digital impressions in implant dentistry, digital scanning techniques, the design and material of the ISBs, and the depth and angulation of the implant. The related titles and abstracts were screened, and the remaining articles that fulfilled the inclusion criteria were selected for full-text readings. Results. The literature search conducted for this review initially resulted in 108 articles, among which only 21 articles fulfilled the criteria for inclusion. Studies were evaluated according to five subjects: accuracy of digital impressions in implant dentistry; the design and material of the intra-oral scan bodies; scanning technique; the influence of implants depth/angulations on the digital impression and accuracy of different intra-oral scanner devices. Conclusions. The accuracy of digital impressions in implant dentistry depends on several aspects. The depth/angulation of the implant, the experience of the operator, the intra-oral scanner used, and environmental conditions may influence the accuracy of digital impressions in implant dentistry. However, it seems that ISBs’ design and material, as well as scanning technique, have a major impact on the trueness and precision of digital impressions in implant dentistry. Future research is suggested for the better understanding of this subject, focusing on the optimization of the ISB design and scanning protocols.