Power equipment operates under high voltages, inducing space charge accumulation on the surface of key insulating structures, which increases the risk of discharge/breakdown and the possibility of maintenance workers experiencing electric shock accidents. Hence, a visualized non-equipment space charge detection method is of great demand in the power industry. Typical electrochromic phenomenon is based on redox of the material, triggered by a voltage smaller than 5 V with a continuous current in μA~mA level, which is not applicable to high electric fields above 106 V/m with pA~nA operation current in power equipment. Until now, no naked-eye observation technique has been realized for space charge detection to ensure the operation of power systems as well as the safety of maintenance workers. In this work, a viologen/poly(vinylidene fluoride-co-hexafluoropropylene)(P(VDF–HFP)) composite is investigated from gel to insulating bulk configurations to achieve high-voltage electrical-insulating electrochromism. The results show that viologen/P(VDF–HFP) composite bulk can withstand high electric fields at the 107 V/m level, and its electrochromism is triggered by space charges. This electrochromism phenomenon can be visually extended by increasing viologen content towards 5 wt.% and shows a positive response to voltage amplitude and application duration. As viologen/P(VDF–HFP) composite bulk exhibits a typical electrical insulating performance, it could be attached to the surface of insulating structures or clamped between metal and insulating materials as a space charge accumulation indicator in high-voltage power equipment.
The effect of thermal aging on the insulation performance of XLPE cables is studied using a new diagnosis technique-direct current integrated charge (DCIC-Q(t)). The influence process of thermal aging on crosslinked polyethylene (XLPE) and the measuring principle of DCIC-Q(t) were described. Several thermal aged XLPE cables were obtained for DCIC-Q(t) experiments. The dynamic charge curve of cables under different thermal aging conditions is obtained, and charge ratio $R$ is proposed to compare the charge injection and accumulation. The permittivity $\varepsilon_{r}$ and conductivity $\gamma$ of XLPE insulation are calculated to analyze the aging level of XLPE cable insulation. It can be concluded that this technique can be useful to monitor the aging of the full-sized cable and has potential to applying in other insulation system.
Electrical breakdown is an important physical phenomenon in power equipment and electronic devices. Recently, the mechanism of AC and DC breakdown has been preliminarily revealed as electrode–dielectric interface breakdown and bulk breakdown, respectively, based on space charge dynamics through numerical calculations. However, the AC breakdown mechanism still lacks enough direct experimental support, which restricts further understanding and the design and development of electrical structures. Here, in this study, LDPE films with various thicknesses ranging from 33 μm to 230 μm were surface modified with ozone for different durations to experimentally investigate DC and AC breakdown mechanism. The results indicate that carbonyl groups (C=O) were introduced onto the film surface, forming shallow surface traps and leading to a decreased average trap depth and an increased trap density. Such a surface oxidation modulated trap distribution led to enhanced space charge injection and bulk electrical field distortion, which decreased DC breakdown strength as the oxidation duration went longer, in all film thicknesses. However, such decreases in breakdown strength occurred only in films below 55 μm under AC stresses, as the enhanced electrical field distortion at the electrode–dielectric interface was more obvious and dominating in thin films. These experimental results further confirm the proposed electrode–dielectric interface breakdown of dielectric films and provide new understandings of space charge modulated electrical breakdown, which fulfills dielectric breakdown theory and benefits the miniaturization of power equipment and electronic devices.
The effect of plasma surface treatment of epoxy resin (EP) AI 2 O 3 micro-composite for different times (1min, 3min and 5min) on vacuum surface flashover performance had been researched in this study. Three critical factors for surface flashover, such as surface chemical composition, surface trap parameters and surface conductivity, had been evaluated through X-ray photoelectron spectroscopy (XPS), surface potential decay (SPD) and Keithley 6517B respectively in order to find out the influence mechanism of plasma treatment. The spectrum of XPS presents that after modification the surface content of O greatly improves with increasing treatment time. SPD results show that shallow trap level decreases first and then increases while shallow trap density increases first and then decreases with the increasing of modification time. DC flashover voltage of samples before and after plasma treatment had been tested in vacuum, the result showed that surface flashover voltage increased first and then decreased with increased processing time, and the highest surface flashover voltage appears at 3min. Surface conductivity increases first and then decreases with the increasing of treatment time too. It can be concluded that plasma treatment can modify surface flashover property of EP Al2O3 micro-composite by altering surface characteristics like trap distribution and surface conductivity.