Yongjie Nie

Dr. Yongjie Nie

Post Doctoral Research
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
YNYongjie Nie
Yongjie Nie
XZXian-Ping Zhao
Xian-Ping Zhao
SLSheng-Tao Li
Sheng-Tao Li
本文在低密度聚乙烯(LDPE)中添加成核剂酚酞, 研究半结晶聚合物的结晶行为、显微结构、陷阱参数以及真空直流沿面闪络性能之间的关联. 显微红外测试结果表明, 酚酞存在于LDPE基体中. 扫描电镜及差式扫描量热测试结果表明, 酚酞掺杂明显改变了LDPE的结晶行为及显微结构, 增加了结晶度及片晶厚度, 减小了球晶尺寸, 并使球晶分布更加均匀. 热刺激电流结果表明, 酚酞掺杂在低密度聚乙烯中引入了更多的深陷阱, 随酚酞浓度增加, α陷阱深度从0.81 eV增加到0.99 eV, γ陷阱深度从0.19 eV增加到0.65 eV. 分析LDPE结晶行为与陷阱参数之间的关系表明, LDPE的陷阱深度随球晶尺寸减小而增大, 陷阱密度随结晶度增大而减小. 酚酞改性后试样的真空沿面闪络电压整体有所提升, 最高提升了48.42%. 分析陷阱深度及陷阱密度与闪络电压之间的“U”型关系表明, 陷阱深度及陷阱密度在影响闪络性能过程中起着相互协调、配合及转化的作用.

8 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
YNYongjie Nie
Yongjie Nie
MZMeng Zhang
Meng Zhang
YZYuanwei Zhu
Yuanwei Zhu
YJYu Jing
Yu Jing
WSWenli Shi
Wenli Shi
SLShengtao Li
Shengtao Li
Power equipment operates under high voltages, inducing space charge accumulation on the surface of key insulating structures, which increases the risk of discharge/breakdown and the possibility of maintenance workers experiencing electric shock accidents. Hence, a visualized non-equipment space charge detection method is of great demand in the power industry. Typical electrochromic phenomenon is based on redox of the material, triggered by a voltage smaller than 5 V with a continuous current in μA~mA level, which is not applicable to high electric fields above 106 V/m with pA~nA operation current in power equipment. Until now, no naked-eye observation technique has been realized for space charge detection to ensure the operation of power systems as well as the safety of maintenance workers. In this work, a viologen/poly(vinylidene fluoride-co-hexafluoropropylene)(P(VDF–HFP)) composite is investigated from gel to insulating bulk configurations to achieve high-voltage electrical-insulating electrochromism. The results show that viologen/P(VDF–HFP) composite bulk can withstand high electric fields at the 107 V/m level, and its electrochromism is triggered by space charges. This electrochromism phenomenon can be visually extended by increasing viologen content towards 5 wt.% and shows a positive response to voltage amplitude and application duration. As viologen/P(VDF–HFP) composite bulk exhibits a typical electrical insulating performance, it could be attached to the surface of insulating structures or clamped between metal and insulating materials as a space charge accumulation indicator in high-voltage power equipment.

11 April 2021
Verified
Conference Paper
Closed access
BHBingrong Huang
Bingrong Huang
WWWeiwang Wang
Weiwang Wang
SLShengtao Li
Shengtao Li
XLXinyuan Li
Xinyuan Li
YNYongjie Nie
Yongjie Nie
QJQihang Jiang
Qihang Jiang
The effect of thermal aging on the insulation performance of XLPE cables is studied using a new diagnosis technique-direct current integrated charge (DCIC-Q(t)). The influence process of thermal aging on crosslinked polyethylene (XLPE) and the measuring principle of DCIC-Q(t) were described. Several thermal aged XLPE cables were obtained for DCIC-Q(t) experiments. The dynamic charge curve of cables under different thermal aging conditions is obtained, and charge ratio $R$ is proposed to compare the charge injection and accumulation. The permittivity $\varepsilon_{r}$ and conductivity $\gamma$ of XLPE insulation are calculated to analyze the aging level of XLPE cable insulation. It can be concluded that this technique can be useful to monitor the aging of the full-sized cable and has potential to applying in other insulation system.

22 November 2023 in Polymers
Verified
Journal Article
Open access
PDF file
YNYongjie Nie
Yongjie Nie
JLJie Liu
Jie Liu
JKJunxin Ke
Junxin Ke
XZXianping Zhao
Xianping Zhao
SLShengtao Li
Shengtao Li
YZYuanwei Zhu
Yuanwei Zhu
Electrical breakdown is an important physical phenomenon in power equipment and electronic devices. Recently, the mechanism of AC and DC breakdown has been preliminarily revealed as electrode–dielectric interface breakdown and bulk breakdown, respectively, based on space charge dynamics through numerical calculations. However, the AC breakdown mechanism still lacks enough direct experimental support, which restricts further understanding and the design and development of electrical structures. Here, in this study, LDPE films with various thicknesses ranging from 33 μm to 230 μm were surface modified with ozone for different durations to experimentally investigate DC and AC breakdown mechanism. The results indicate that carbonyl groups (C=O) were introduced onto the film surface, forming shallow surface traps and leading to a decreased average trap depth and an increased trap density. Such a surface oxidation modulated trap distribution led to enhanced space charge injection and bulk electrical field distortion, which decreased DC breakdown strength as the oxidation duration went longer, in all film thicknesses. However, such decreases in breakdown strength occurred only in films below 55 μm under AC stresses, as the enhanced electrical field distortion at the electrode–dielectric interface was more obvious and dominating in thin films. These experimental results further confirm the proposed electrode–dielectric interface breakdown of dielectric films and provide new understandings of space charge modulated electrical breakdown, which fulfills dielectric breakdown theory and benefits the miniaturization of power equipment and electronic devices.

1 May 2018
Verified
Conference Paper
Closed access
WYWenying Yue
Wenying Yue
Daomin MinDaomin Min
Daomin Min
YNYongjie Nie
Yongjie Nie
SLShengtao Li
Shengtao Li
The effect of plasma surface treatment of epoxy resin (EP) AI 2 O 3 micro-composite for different times (1min, 3min and 5min) on vacuum surface flashover performance had been researched in this study. Three critical factors for surface flashover, such as surface chemical composition, surface trap parameters and surface conductivity, had been evaluated through X-ray photoelectron spectroscopy (XPS), surface potential decay (SPD) and Keithley 6517B respectively in order to find out the influence mechanism of plasma treatment. The spectrum of XPS presents that after modification the surface content of O greatly improves with increasing treatment time. SPD results show that shallow trap level decreases first and then increases while shallow trap density increases first and then decreases with the increasing of modification time. DC flashover voltage of samples before and after plasma treatment had been tested in vacuum, the result showed that surface flashover voltage increased first and then decreased with increased processing time, and the highest surface flashover voltage appears at 3min. Surface conductivity increases first and then decreases with the increasing of treatment time too. It can be concluded that plasma treatment can modify surface flashover property of EP Al2O3 micro-composite by altering surface characteristics like trap distribution and surface conductivity.

4 November 2022
Verified
Conference Paper
Open access
JLJie Li
Jie Li
HCHui Chen
Hui Chen
JYJunwen Yang
Junwen Yang
SLSiyang Liu
Siyang Liu
YNYongjie Nie
Yongjie Nie
JLJinyuan Li
Jinyuan Li