Objective: In the field of forensic science, sex discrimination of skeletons is an important identification item for personal identification. The individual sex discrimination method using skeletons includes a determination method using measurement values and a macroscopic form observation method. Both methods have advantage and disadvantage. In this study, we used the homologous model technique and principal component (PC) analysis to determine gender difference from morphology of the mandible. Methods and materials: 45 patients (23 males and 22 females) of CT imaging for tooth extraction from January 2018 to March 2019 at department of oral surgery, Osaka Medical College. The mean age was 43.1 ± 14.6. Patients with less than 14 remaining teeth were excluded because the number of remaining teeth may affect the shape of the mandible. 3D images were constructed, and 20 landmarks plotting on the 3D model surfaces. We generated template models of the mandible consisting of approximately 8434 polygons. The template model automatically fitted into the individually scanned point cloud of the mandible by minimising external and internal energy functions. As described above, the mandibles were constructed for each sample by using the Homologous Body Modeling software (HBM, Digital Human Technology, Inc.) and the mHBM-Rugle (Medic Engineering Corporation). The mandibles were analysed using the PCA. Results: The contribution of the most important PC was found to be 27.2%. 12 PCs explained over 75% of the total variance. That is, it was able to express 75% or more of the mandible expression with 12 PCs. A significant difference between male and female was observed in the first PCs (Wilcoxon test, p < 0.05). Visualising the result of the first PC showed that the mandibular branch of male was larger than that of female, and the mandible angle was overhanging outside. Conclusion: This method is a combination of the determination method using the previous measurement values and the determination using macroscopic observation, and is considered to be innovative method.
Selective laser melting (SLM) is a promising technology capable of producing individual characteristics with a high degree of surface roughness for implants. These surfaces can be modified so as to increase their osseointegration, bone generation and biocompatibility, features which are critical to their clinical success. In this study, we evaluated the effects on preosteoblast proliferation and differentiation of titanium metal (Ti) with a high degree of roughness (Ra = 5.4266 ± 1.282 µm) prepared by SLM (SLM-Ti) that was also subjected to surface bioactive treatment by mixed acid and heat (MAH). The results showed that the MAH treatment further increased the surface roughness, wettability and apatite formation capacity of SLM-Ti, features which are useful for cell attachment and bone bonding. Quantitative measurement of osteogenic-related gene expression by RT-PCR indicated that the MC3T3-E1 cells on the SLM-Ti MAH surface presented a stronger tendency towards osteogenic differentiation at the genetic level through significantly increased expression of Alp, Ocn, Runx2 and Opn. We conclude that bio-activated SLM-Ti enhanced preosteoblast differentiation. These findings suggest that the mixed acid and heat treatment on SLM-Ti is promising method for preparing the next generation of orthopedic and dental implants because of its apatite formation and cell differentiation capability.
The additive manufacturing (AM) technique has attracted attention as one of the fully customizable medical material technologies. In addition, the development of new surface treatments has been investigated to improve the osteogenic ability of the AM titanium (Ti) plate. The purpose of this study was to evaluate the osteogenic activity of the AM Ti with mixed-acid and heat (MAH) treatment. Fully customized AM Ti plates were created with a curvature suitable for rat calvarial bone, and they were examined in a group implanted with the MAH-treated Ti in comparison with the untreated (UN) group. The AM Ti plates were fixed to the surface of rat calvarial bone, followed by extraction of the calvarial bone 1, 4, 8, and 12 weeks after implantation. The bonding between the bone and Ti was evaluated mechanically. In addition, AM Ti plates removed from the bone were examined histologically by electron microscopy and Villanueva–Goldner stain. The mechanical evaluation showed significantly stronger bone-bonding in the MAH group than in the UN group. In addition, active bone formation was seen histologically in the MAH group. Therefore, these findings indicate that MAH resulted in rapid and strong bonding between cortical bone and Ti.
Jaw reconstruction using an additive-manufacturing titanium artificial bone (AMTAB) has recently attracted considerable attention. The synthesis of a titanium artificial bone is based on three-dimensional computed tomography images acquired before surgery. A histological evaluation of porous AMTAB (pAMTAB) embedded in rat calvarial bone defects was conducted. This study examined three groups: rats implanted with mixed-acid and heat-treated pAMTAB, rats implanted with untreated pAMTAB, and rats with no implant. In both pAMTAB groups, bone defects were created in rat calvarial bones using a 5-mm trephine bar, followed by pAMTAB implantation. The pAMTAB was fixed to the defect using the fitting force of the surrounding bones. The rats were sacrificed at 4, 8, and 16 weeks after implantation, and the skull was dissected. Undecalcified ground slides were prepared and stained with Villanueva Goldner. Compared with the no implant control group, both pAMTAB groups exhibited new bone formation inside the defect, with greater bone formation in the mixed-acid and heat-treated pAMTAB group than in the untreated pAMTAB group, but the difference was not significant. These data suggest that pAMTAB induces bone formation after implantation in bone defects. Bone formation appears to be enhanced by prior mixed-acid and heat-treated pAMTAB.
Additive manufacturing techniques are being used in the medical field. Orthopedic hip prostheses and denture bases are designed and fabricated based on the patient’s computer-aided design (CAD) data. We attempted to incorporate this technique into dental implant bone augmentation. Surgical simulation was performed using patient data. Fourteen patients underwent bone augmentation using a selective laser melting (SLM) titanium mesh plate. The results showed no evidence of infection in any of the 14 patients. In 12 patients, only one fixation screw was used, and good results were obtained. The SLM titanium mesh plate was good adaptation in all cases, with bone occupancy greater than 90%. The average bone resorption of the marginal alveolar bone from the time of dental implant placement to the time of the superstructure placement was 0.69 ± 0.25 mm. Implant superstructures were placed in all cases, and bone augmentation with SLM titanium mesh plates was considered a useful technique.
In the field of oral and maxillofacial surgery, establishment of a new method for predicting morphology is desirable. Therefore, the purpose of the present study was to establish a new method for predicting the original shape of a mandibular defect site using the homologous modeling technique. This study used data from 44 patients who underwent computed tomography in the Department of Oral Surgery at Osaka Medical College. Two types of homologous models were constructed: total mandible (TM) and half mandible (HM). Principal component analysis (PCA) was performed using point cloud data of the homologous model M and homologous model HM, and a multiple regression equation was created using the PC value of TM as the object variable and PC value of HM as the explanatory variable. The predicted PC (M) was created from PC (HM) using a regression formula, back-calculated from point cloud data from PC (M), to create the predicted mandible model. Finally, the original image (TC-M) and estimated mandible were superposed and examined. The mean absolute error between the predicted mandible and actual mandible was 1.04 ± 1.35 mm. We believe that this method will be applicable in actual clinical practice.