Sylvain Cardin

Dr. Sylvain Cardin

Navy Medical Research Unit, JBSA Fort Sam Houston, San Antonio, TX 78234, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Victor A. ConvertinoVictor A. Convertino
Victor A. Convertino
SSSteven Schauer
Steven Schauer
Erik WeitzelErik Weitzel
Erik Weitzel
SCSylvain Cardin
Sylvain Cardin
MSMark E. Stackle
Mark E. Stackle
OIOmer Inan
Omer Inan
Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sensor technologies that can harness necessary electronic physiological signal integration with a current state-of-the-art predictive machine-learning algorithm that provides early clinical assessment of hypovolemia status to impact patient outcome. The ability to study the physiology of hemorrhage using a human model of progressive central hypovolemia led to the development of a novel machine-learning algorithm known as the compensatory reserve measurement (CRM). Greater sensitivity, specificity, and diagnostic accuracy to detect hemorrhage and onset of decompensated shock has been demonstrated by the CRM when compared to all standard vital signs and hemodynamic variables. The development of CRM revealed that continuous measurements of changes in arterial waveform features represented the most integrated signal of physiological compensation for conditions of reduced systemic oxygen delivery. In this review, detailed analysis of sensor technologies that include photoplethysmography, tonometry, ultrasound-based blood pressure, and cardiogenic vibration are identified as potential candidates for harnessing arterial waveform analog features required for real-time calculation of CRM. The integration of wearable sensors with the CRM algorithm provides a potentially powerful medical monitoring advancement to save civilian and military lives in emergency medical settings.

30 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Victor A. ConvertinoVictor A. Convertino
Victor A. Convertino
RTRobert W. Techentin
Robert W. Techentin
RPRuth Poole
Ruth Poole
ADAshley C. Dacy
Ashley C. Dacy
ACAshli N. Carlson
Ashli N. Carlson
OIOmer Inan
Omer Inan
The application of artificial intelligence (AI) has provided new capabilities to develop advanced medical monitoring sensors for detection of clinical conditions of low circulating blood volume such as hemorrhage. The purpose of this study was to compare for the first time the discriminative ability of two machine learning (ML) algorithms based on real-time feature analysis of arterial waveforms obtained from a non-invasive continuous blood pressure system (Finometer®) signal to predict the onset of decompensated shock: the compensatory reserve index (CRI) and the compensatory reserve metric (CRM). One hundred ninety-one healthy volunteers underwent progressive simulated hemorrhage using lower body negative pressure (LBNP). The least squares means and standard deviations for each measure were assessed by LBNP level and stratified by tolerance status (high vs. low tolerance to central hypovolemia). Generalized Linear Mixed Models were used to perform repeated measures logistic regression analysis by regressing the onset of decompensated shock on CRI and CRM. Sensitivity and specificity were assessed by calculation of receiver-operating characteristic (ROC) area under the curve (AUC) for CRI and CRM. Values for CRI and CRM were not distinguishable across levels of LBNP independent of LBNP tolerance classification, with CRM ROC AUC (0.9268) being statistically similar (p = 0.134) to CRI ROC AUC (0.9164). Both CRI and CRM ML algorithms displayed discriminative ability to predict decompensated shock to include individual subjects with varying levels of tolerance to central hypovolemia. Arterial waveform feature analysis provides a highly sensitive and specific monitoring approach for the detection of ongoing hemorrhage, particularly for those patients at greatest risk for early onset of decompensated shock and requirement for implementation of life-saving interventions.

7 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JKJacob Kimball
Jacob Kimball
OIOmer Inan
Omer Inan
Victor A. ConvertinoVictor A. Convertino
Victor A. Convertino
SCSylvain Cardin
Sylvain Cardin
MSMichael N. Sawka
Michael N. Sawka
Hypovolemia is a physiological state of reduced blood volume that can exist as either (1) absolute hypovolemia because of a lower circulating blood (plasma) volume for a given vascular space (dehydration, hemorrhage) or (2) relative hypovolemia resulting from an expanded vascular space (vasodilation) for a given circulating blood volume (e.g., heat stress, hypoxia, sepsis). This paper examines the physiology of hypovolemia and its association with health and performance problems common to occupational, military and sports medicine. We discuss the maturation of individual-specific compensatory reserve or decompensation measures for future wearable sensor systems to effectively manage these hypovolemia problems. The paper then presents areas of future work to allow such technologies to translate from lab settings to use as decision aids for managing hypovolemia. We envision a future that incorporates elements of the compensatory reserve measure with advances in sensing technology and multiple modalities of cardiovascular sensing, additional contextual measures, and advanced noise reduction algorithms into a fully wearable system, creating a robust and physiologically sound approach to manage physical work, fatigue, safety and health issues associated with hypovolemia for workers, warfighters and athletes in austere conditions.

17 May 2023 in Journal of Trauma and Acute Care Surgery
Verified
Journal Article
Closed access
Victor A. ConvertinoVictor A. Convertino
Victor A. Convertino
PTPatrick Thompson
Patrick Thompson
NKNatalie J. Koons
Natalie J. Koons
TLTuan D. Le
Tuan D. Le
JLJ. Brian Lanier
J. Brian Lanier
SCSylvain Cardin
Sylvain Cardin
BACKGROUND: Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. METHODS: We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. RESULTS: The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). CONCLUSION: Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia. LEVEL OF EVIDENCE: Diagnostic Test or Criteria; Level III.

Verified
Journal Article
Open access
PDF file
JSJessica Stukel Shah
Jessica Stukel Shah
JMJoseph Macaitis
Joseph Macaitis
BLBridney Lundquist
Bridney Lundquist
BJBrian Johnstone
Brian Johnstone
MCMichael Coleman
Michael Coleman
ABAlexander Burdette
Alexander Burdette
Traumatic brain injury (TBI) and hemorrhage remain challenging to treat in austere conditions. Developing a therapeutic to mitigate the associated pathophysiology is critical to meet this treatment gap, especially as these injuries and associated high mortality are possibly preventable. Here, Thera-101 (T-101) was evaluated as low-volume resuscitative fluid in a rat model of TBI and hemorrhage. The therapeutic, T-101, is uniquely situated as a TBI and hemorrhage intervention. It contains a cocktail of proteins and microvesicles from the secretome of adipose-derived mesenchymal stromal cells that can act on repair and regenerative mechanisms associated with poly-trauma. T-101 efficacy was determined at 4, 24, 48, and 72 h post-injury by evaluating blood chemistry, inflammatory chemo/cytokines, histology, and diffusion tensor imaging. Blood chemistry indicated that T-101 reduced the markers of liver damage to Sham levels while the levels remained elevated with the control (saline) resuscitative fluid. Histology supports the potential protective effects of T-101 on the kidneys. Diffusion tensor imaging showed that the injury caused the most damage to the corpus callosum and the fimbria. Immunohistochemistry suggests that T-101 may mitigate astrocyte activation at 72 h. Together, these data suggest that T-101 may serve as a potential field deployable low-volume resuscitation therapeutic.