Omer Inan

Prof. Omer Inan

Georgia Institute of Technology
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
JHJIN-OH HAHN
JIN-OH HAHN
OIOmer Inan
Omer Inan
LMLalit K. Mestha
Lalit K. Mestha
CKChang-Sei Kim
Chang-Sei Kim
SKSurvi Kyal
Survi Kyal
Ubiquitous blood pressure (BP) monitoring is needed to improve hypertension detection and control and is becoming feasible due to recent technological advances such as in wearable sensing. Pulse transit time (PTT) represents a well-known potential approach for ubiquitous BP monitoring. The goal of this review is to facilitate the achievement of reliable ubiquitous BP monitoring via PTT. We explain the conventional BP measurement methods and their limitations; present models to summarize the theory of the PTT-BP relationship; outline the approach while pinpointing the key challenges; overview the previous work toward putting the theory to practice; make suggestions for best practice and future research; and discuss realistic expectations for the approach.

31 July 2020 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
OIOmer Inan
Omer Inan
PTP. Tenaerts
P. Tenaerts
SPS. A. Prindiville
S. A. Prindiville
HRH. R. Reynolds
H. R. Reynolds
DDD. S. Dizon
D. S. Dizon
RCR. M. Califf
R. M. Califf
Clinical trials are a fundamental tool used to evaluate the efficacy and safety of new drugs and medical devices and other health system interventions. The traditional clinical trials system acts as a quality funnel for the development and implementation of new drugs, devices and health system interventions. The concept of a “digital clinical trial” involves leveraging digital technology to improve participant access, engagement, trial-related measurements, and/or interventions, enable concealed randomized intervention allocation, and has the potential to transform clinical trials and to lower their cost. In April 2019, the US National Institutes of Health (NIH) and the National Science Foundation (NSF) held a workshop bringing together experts in clinical trials, digital technology, and digital analytics to discuss strategies to implement the use of digital technologies in clinical trials while considering potential challenges. This position paper builds on this workshop to describe the current state of the art for digital clinical trials including (1) defining and outlining the composition and elements of digital trials; (2) describing recruitment and retention using digital technology; (3) outlining data collection elements including mobile health, wearable technologies, application programming interfaces (APIs), digital transmission of data, and consideration of regulatory oversight and guidance for data security, privacy, and remotely provided informed consent; (4) elucidating digital analytics and data science approaches leveraging artificial intelligence and machine learning algorithms; and (5) setting future priorities and strategies that should be addressed to successfully harness digital methods and the myriad benefits of such technologies for clinical research.

1 January 2018 in Circulation: Heart Failure
Verified
Journal Article
Closed access
PDF file
OIOmer Inan
Omer Inan
MPMaziyar Baran Pouyan
Maziyar Baran Pouyan
AJAbdul Q. Javaid
Abdul Q. Javaid
SDSean Dowling
Sean Dowling
MEMozziyar Etemadi
Mozziyar Etemadi
LKLiviu Klein
Liviu Klein
Background: Remote monitoring of patients with heart failure (HF) using wearable devices can allow patient-specific adjustments to treatments and thereby potentially reduce hospitalizations. We aimed to assess HF state using wearable measurements of electrical and mechanical aspects of cardiac function in the context of exercise. Methods and Results: Patients with compensated (outpatient) and decompensated (hospitalized) HF were fitted with a wearable ECG and seismocardiogram sensing patch. Patients stood at rest for an initial recording, performed a 6-minute walk test, and then stood at rest for 5 minutes of recovery. The protocol was performed at the time of outpatient visit or at 2 time points (admission and discharge) during an HF hospitalization. To assess patient state, we devised a method based on comparing the similarity of the structure of seismocardiogram signals after exercise compared with rest using graph mining (graph similarity score). We found that graph similarity score can assess HF patient state and correlates to clinical improvement in 45 patients (13 decompensated, 32 compensated). A significant difference was found between the groups in the graph similarity score metric (44.4±4.9 [decompensated HF] versus 35.2±10.5 [compensated HF]; P <0.001). In the 6 decompensated patients with longitudinal data, we found a significant change in graph similarity score from admission (decompensated) to discharge (compensated; 44±4.1 [admitted] versus 35±3.9 [discharged]; P <0.05). Conclusions: Wearable technologies recording cardiac function and machine learning algorithms can assess compensated and decompensated HF states by analyzing cardiac response to submaximal exercise. These techniques can be tested in the future to track the clinical status of outpatients with HF and their response to pharmacological interventions.

1 October 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
KSKaan Sel
Kaan Sel
DODeen Osman
Deen Osman
FZFatemeh Zare
Fatemeh Zare
SSSina Masoumi Shahrbabak
Sina Masoumi Shahrbabak
LBLaura Brattain
Laura Brattain
RJRoozbeh Jafari
Roozbeh Jafari
The past several decades have seen rapid advances in diagnosis and treatment of cardiovascular diseases and stroke, enabled by technological breakthroughs in imaging, genomics, and physiological monitoring, coupled with therapeutic interventions. We now face the challenge of how to (1) rapidly process large, complex multimodal and multiscale medical measurements; (2) map all available data streams to the trajectories of disease states over the patient's lifetime; and (3) apply this information for optimal clinical interventions and outcomes. Here we review new advances that may address these challenges using digital twin technology to fulfill the promise of personalized cardiovascular medical practice. Rooted in engineering mechanics and manufacturing, the digital twin is a virtual representation engineered to model and simulate its physical counterpart. Recent breakthroughs in scientific computation, artificial intelligence, and sensor technology have enabled rapid bidirectional interactions between the virtual‐physical counterparts with measurements of the physical twin that inform and improve its virtual twin, which in turn provide updated virtual projections of disease trajectories and anticipated clinical outcomes. Verification, validation, and uncertainty quantification builds confidence and trust by clinicians and patients in the digital twin and establishes boundaries for the use of simulations in cardiovascular medicine. Mechanistic physiological models form the fundamental building blocks of the personalized digital twin that continuously forecast optimal management of cardiovascular health using individualized data streams. We present exemplars from the existing body of literature pertaining to mechanistic model development for cardiovascular dynamics and summarize existing technical challenges and opportunities pertaining to the foundation of a digital twin.

11 December 2018 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Open access
RARishad Ahmed
Rishad Ahmed
YZYuan Zhang
Yuan Zhang
ZFZhiquan Feng
Zhiquan Feng
BLBenny Lo
Benny Lo
OIOmer Inan
Omer Inan
Hongen LiaoHongen Liao
Hongen Liao
Dementia, a chronic and progressive cognitive declination of brain function caused by disease or impairment, is becoming more prevalent due to the aging population. A major challenge in dementia is achieving accurate and timely diagnosis. In recent years, neuroimaging with computer-aided algorithms have made remarkable advances in addressing this challenge. The success of these approaches is mostly attributed to the application of machine learning techniques for neuroimaging. In this review paper, we present a comprehensive survey of automated diagnostic approaches for dementia using medical image analysis and machine learning algorithms published in the recent years. Based on the rigorous review of the existing works, we have found that, while most of the studies focused on Alzheimer's disease, recent research has demonstrated reasonable performance in the identification of other types of dementia remains a major challenge. Multimodal imaging analysis deep learning approaches have shown promising results in the diagnosis of these other types of dementia. The main contributions of this review paper are as follows. 1) Based on the detailed analysis of the existing literature, this paper discusses neuroimaging procedures for dementia diagnosis. 2) It systematically explains the most recent machine learning techniques and, in particular, deep learning approaches for early detection of dementia.

15 December 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SMStephanie L.-O. Martin
Stephanie L.-O. Martin
ACAndrew M. Carek
Andrew M. Carek
CKChang-Sei Kim
Chang-Sei Kim
HAHazar Ashouri
Hazar Ashouri
OIOmer Inan
Omer Inan
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms – and thus PTT through larger, more elastic arteries – in terms of its ability to improve tracking of BP in individual subjects. We measured “scale PTT”, conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of −0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of −0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP.