1 July 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
WDWolfgang Drexler
Wolfgang Drexler
MLMengyang Liu
Mengyang Liu
AKAbhishek Kumar
Abhishek Kumar
TKTschackad Kamali
Tschackad Kamali
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
In the last 25 years, optical coherence tomography (OCT) has advanced to be one of the most innovative and most successful translational optical imaging techniques, achieving substantial economic impact as well as clinical acceptance. This is largely owing to the resolution improvements by a factor of 10 to the submicron regime and to the imaging speed increase by more than half a million times to more than 5 million A-scans per second, with the latter one accomplished by the state-of-the-art swept source laser technologies that are reviewed in this article. In addition, parallelization of OCT detection, such as line-field and full-field OCT, has shortened the acquisition time even further by establishing quasi-akinetic scanning. Besides the technical improvements, several functional and contrast-enhancing OCT applications have been investigated, among which the label-free angiography shows great potential for future studies. Finally, various multimodal imaging modalities with OCT incorporated are reviewed, in that these multimodal implementations can synergistically compensate for the fundamental limitations of OCT when it is used alone.

15 October 2002 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BPB. Povazay
B. Povazay
KBK. Bizheva
K. Bizheva
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
BHB. Hermann
B. Hermann
HSH. Sattmann
H. Sattmann
ESE. Scherzer
E. Scherzer
Optical coherence tomography (OCT) with unprecedented submicrometer axial resolution achieved by use of a photonic crystal fiber in combination with a compact sub-10-fs Ti:sapphire laser (Femtolasers Produktions) is demonstrated for what the authors believe is the first time. The emission spectrum ranges from 550 to 950 nm (λc=725 nm, Pout=27 mW), resulting in a free-space axial OCT resolution of ∼0.75 µm, corresponding to ∼0.5 µm in biological tissue. Submicrometer-resolution OCT is demonstrated in vitro on human colorectal adenocarcinoma cells HT-29. This novel light source has great potential for development of spectroscopic OCT because its spectrum covers the absorption bands of several biological chromophores.

1 May 2003 in Archives of Ophthalmology (1950)
Verified
Journal Article
Closed access
PDF file
WDWolfgang Drexler
Wolfgang Drexler
HSHarald Sattmann
Harald Sattmann
BHBoris Hermann
Boris Hermann
TKTony H. Ko
Tony H. Ko
MSMichael Stur
Michael Stur
AFAdolf F. Fercher
Adolf F. Fercher
Review from JAMA Ophthalmology — Enhanced Visualization of Macular Pathology With the Use of Ultrahigh-Resolution Optical Coherence Tomography

15 September 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BHB. Hermann
B. Hermann
EFEnrique Josua Fernández
Enrique Josua Fernández
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
HSH. Sattmann
H. Sattmann
AFA. F. Fercher
A. F. Fercher
PAP. Artal
P. Artal
Merging of ultrahigh-resolution optical coherence tomography (UHR OCT) and adaptive optics (AO), resulting in high axial (3 µm) and improved transverse resolution (5–10 µm) is demonstrated for the first time to our knowledge in in vivo retinal imaging. A compact (300 mm×300 mm) closed-loop AO system, based on a real-time Hartmann–Shack wave-front sensor operating at 30 Hz and a 37-actuator membrane deformable mirror, is interfaced to an UHR OCT system, based on a commercial OCT instrument, employing a compact Ti:sapphire laser with 130-nm bandwidth. Closed-loop correction of both ocular and system aberrations results in a residual uncorrected wave-front rms of 0.1 µm for a 3.68-mm pupil diameter. When this level of correction is achieved, OCT images are obtained under a static mirror configuration. By use of AO, an improvement of the transverse resolution of two to three times, compared with UHR OCT systems used so far, is obtained. A significant signal-to-noise ratio improvement of up to 9 dB in corrected compared with uncorrected OCT tomograms is also achieved.

1 January 2004 in Optics Express
Verified
Journal Article
Closed access
PDF file
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
WDW. Drexler
W. Drexler
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
BHB. Hermann
B. Hermann
TBT. Bajraszewski
T. Bajraszewski
AFA. F. Fercher
A. F. Fercher
We present, for the first time, in vivo ultrahigh resolution (~2.5 μm in tissue), high speed (10000 A-scans/second equivalent acquisition rate sustained over 160 A-scans) retinal imaging obtained with Fourier domain (FD) OCT employing a commercially available, compact (500×260mm), broad bandwidth (120 nm at full-width-at-half-maximum centered at 800 nm) Titanium:sapphire laser (Femtosource Integral OCT, Femtolasers Produktions GmbH). Resolution and sampling requirements, dispersion compensation as well as dynamic range for ultrahigh resolution FD OCT are carefully analyzed. In vivo OCT sensitivity performance achieved by ultrahigh resolution FD OCT was similar to that of ultrahigh resolution time domain OCT, although employing only 2–3 times less optical power (~300 μW). Visualization of intra-retinal layers, especially the inner and outer segment of the photoreceptor layer, obtained by FDOCT was comparable to that, accomplished by ultrahigh resolution time domain OCT, despite an at least 40 times higher data acquisition speed of FD OCT.

1 January 2005 in Optics Express
Verified
Journal Article
Closed access
PDF file
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
BPB. Povazay
B. Povazay
BHB. Hermann
B. Hermann
HSH. Sattmann
H. Sattmann
ACA. Chavez-Pirson
A. Chavez-Pirson
WDW. Drexler
W. Drexler
For the first time in vivo retinal imaging has been performed with a new compact, low noise Yb-based ASE source operating in the 1 µm range (NP Photonics, λc=1040 nm, Δλ=50 nm, Pout=30 mW) at the dispersion minimum of water with ~7 µm axial resolution. OCT tomograms acquired at 800 nm are compared to those achieved at 1040 nm showing about 200 µm deeper penetration into the choroid below the retinal pigment epithelium. Retinal OCT at longer wavelengths significantly improves the visualization of the retinal pigment epithelium/choriocapillaris/choroid interface and superficial choroidal layers as well as reduces the scattering through turbid media and therefore might provide a better diagnosis tool for early stages of retinal pathologies such as age related macular degeneration which is accompanied by choroidal neovascularization, i.e. extensive growth of new blood vessels in the choroid and retina.