Wolfgang Drexler

Prof. Wolfgang Drexler

Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna,1090, Austria

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2001 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
WDWolfgang Drexler
Wolfgang Drexler
UMUwe Morgner
Uwe Morgner
RGRavi K. Ghanta
Ravi K. Ghanta
FKFranz X. Kärtner
Franz X. Kärtner
JSJoel S Schuman
Joel S Schuman
JFJames G. Fujimoto
James G. Fujimoto

1 January 2008 in Progress in Retinal and Eye Research
Verified
Journal Article
Closed access
WDWolfgang Drexler
Wolfgang Drexler
JFJ Fujimoto
J Fujimoto

1 July 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
WDWolfgang Drexler
Wolfgang Drexler
MLMengyang Liu
Mengyang Liu
AKAbhishek Kumar
Abhishek Kumar
TKTschackad Kamali
Tschackad Kamali
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
In the last 25 years, optical coherence tomography (OCT) has advanced to be one of the most innovative and most successful translational optical imaging techniques, achieving substantial economic impact as well as clinical acceptance. This is largely owing to the resolution improvements by a factor of 10 to the submicron regime and to the imaging speed increase by more than half a million times to more than 5 million A-scans per second, with the latter one accomplished by the state-of-the-art swept source laser technologies that are reviewed in this article. In addition, parallelization of OCT detection, such as line-field and full-field OCT, has shortened the acquisition time even further by establishing quasi-akinetic scanning. Besides the technical improvements, several functional and contrast-enhancing OCT applications have been investigated, among which the label-free angiography shows great potential for future studies. Finally, various multimodal imaging modalities with OCT incorporated are reviewed, in that these multimodal implementations can synergistically compensate for the fundamental limitations of OCT when it is used alone.

1 January 2004 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
WDWolfgang Drexler
Wolfgang Drexler
In the past two decades, optical coherence tomography (OCT) has been established as an adjunct diagnostic technique for noninvasive, high-resolution, cross-sectional imaging in a variety of medical fields. The rapid development of ultrabroad bandwidth light sources has recently enabled a significant improvement in OCT imaging resolution, demonstrating the potential of OCT to accomplish its original goal of performing noninvasive optical biopsies, i.e., the in vivo visualization of microstructural morphology in situ, which had previously only been possible with histopathology. In addition, these novel light sources might also enable the use of spectroscopic OCT, an extension of ultrahigh-resolution OCT, for enhancing image contrast as well as detecting spatially resolved functional, biochemical tissue information. State-of-the-art-light sources that now permit ultrahigh-resolution OCT covering the whole wavelength region from 500 to 1600 nm are reviewed and fundamental limitations of OCT image resolution are discussed. Ex vivo ultrahigh-resolution OCT tomograms are compared with histological results; first clinical in vivo ultrahigh-resolution OCT and preliminary spectroscopic OCT results are presented and their impact for future clinical and research applications is discussed. © 2004 Society of Photo-Optical Instrumentation Engineers.

15 October 2002 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BPB. Povazay
B. Povazay
KBK. Bizheva
K. Bizheva
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
BHB. Hermann
B. Hermann
HSH. Sattmann
H. Sattmann
ESE. Scherzer
E. Scherzer
Optical coherence tomography (OCT) with unprecedented submicrometer axial resolution achieved by use of a photonic crystal fiber in combination with a compact sub-10-fs Ti:sapphire laser (Femtolasers Produktions) is demonstrated for what the authors believe is the first time. The emission spectrum ranges from 550 to 950 nm (λc=725 nm, Pout=27 mW), resulting in a free-space axial OCT resolution of ∼0.75 µm, corresponding to ∼0.5 µm in biological tissue. Submicrometer-resolution OCT is demonstrated in vitro on human colorectal adenocarcinoma cells HT-29. This novel light source has great potential for development of spectroscopic OCT because its spectrum covers the absorption bands of several biological chromophores.

1 May 2003 in Archives of Ophthalmology (1950)
Verified
Journal Article
Closed access
PDF file
WDWolfgang Drexler
Wolfgang Drexler
HSHarald Sattmann
Harald Sattmann
BHBoris Hermann
Boris Hermann
TKTony H. Ko
Tony H. Ko
MSMichael Stur
Michael Stur
AFAdolf F. Fercher
Adolf F. Fercher
Review from JAMA Ophthalmology — Enhanced Visualization of Macular Pathology With the Use of Ultrahigh-Resolution Optical Coherence Tomography