OKTAY ARIKAN

Dr. OKTAY ARIKAN

Yildiz Technical University
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2017 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
ETEyup Taslak
Eyup Taslak
OAOKTAY ARIKAN
OKTAY ARIKAN
CKCelal Fadil Kumru
Celal Fadil Kumru
ÖKÖzcan Kalenderli
Özcan Kalenderli

12 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
Cihat Cagdas UydurCihat Cagdas Uydur
Cihat Cagdas Uydur
OAOKTAY ARIKAN
OKTAY ARIKAN
It is known that the failure of cable terminations causes power outages and impairs system quality and continuity. Besides, serious economic losses on both the distribution and consumer sides occur. In this study, the dielectric behavior of the cable and the faults caused by the defects in the cable termination under overvoltage has been examined. As test samples, 12 kV XLPE insulated cable is used and they were aged at three (3*U0) and five (5*U0) times the rated voltage. After each aging cycle, dielectric parameters of the cable were measured by an OMIRCRON CPC100/CPTD1 device, and the partial discharge (PD) was measured by an OMICRON MPD600 device. In the measurements, it was observed that the cable was broken down at different aging cycle numbers as a result of defects in the cable termination due to weak workmanship. As a result of the measurements, it is concluded that defects in the cable termination give information about the increase in the probability of failure and the decrease of the cable lifetime. Consequently, it is concluded that fine workmanship and timely maintenance of cable terminations prevent the system from unwanted power outages and economic losses.

19 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AEAyşe Kübra Erenoğlu
Ayşe Kübra Erenoğlu
AÇAlper Çiçek
Alper Çiçek
OAOKTAY ARIKAN
OKTAY ARIKAN
OEOzan Erdinc
Ozan Erdinc
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
Even renewable energy sources provide several advantages, especially from an environmental point of view, where the world has faced great challenges in the last few decades; several negative issues also exist regarding the integration of renewable resources-based power production units in electric power systems. One of the main problems related to pivotal renewable energy resources such as solar, wind, etc., is their stochastic and uncontrollable nature in terms of power production. Therefore, this stochasticity in the supply side of the power system may pose many challenges for system operators. This issue is also problematic for smaller applications where the stochastic production by a main resource, such as a roof-top photovoltaic system, and load demand may not match perfectly at each time instant and therefore should be compensated by additional resources such as battery-based energy storage systems. Herein, the economic considerations to ensure minimum costs for such a hybrid system design are vital so as to increase the penetration of such systems. Therefore, the optimal sizing and planning of hybrid systems have recently gained increasing importance to enhance power system operation in the context of the smart grid paradigm. From a different perspective, harmonics are one of the most important power quality problems in system operations caused by widespread integration of power electronic loads with non-linear characteristics that should be considered. Thus, a new approach for grid-connected hybrid renewable energy system sizing is provided. In order to determine optimal capacities for photovoltaic (PV) and energy storage system (ESS) units for covering residential consumer demand, a mixed integer linear programming (MILP)-based formulation is presented. The main objective is minimizing total costs of the system consisting of investment, capital and maintenance cost functions. A daily power curve is created accurately with real measurements of non-linear loads considering harmonic contents of smart home appliances in Yildiz Technical University, Istanbul, Turkey. In addition, real radiation and temperature values are used in PV production as well as dynamic pricing schemes for realistic evaluations. Moreover, optimal sizing results are compared for both the harmonic-based power curve and rated power curve in terms of satisfying objective function.

7 August 2022 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Cihat Cagdas UydurCihat Cagdas Uydur
Cihat Cagdas Uydur
OAOKTAY ARIKAN
OKTAY ARIKAN


12 March 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
FAFırat Akın
Fırat Akın
OAOKTAY ARIKAN
OKTAY ARIKAN
BKBaris Kucukaydin
Baris Kucukaydin