Based on electromechanical impedance (EMI) technology, we studied the indication effect of each characterization index on flange bolt looseness under different noise levels. A new evaluation index T is constructed to solve the problem that the minor looseness and noise under the actual monitoring environment cannot be distinguished with existing indexes. The results show that among the five characterization indexes, the root mean square deviation (RMSD) and the correlation coefficient deviation (CCD) can reflect the minor looseness sensitively and are positively correlated with the degree of looseness. They also have good performance of looseness identification under the noise of 30 dBW. However, the indexes’ indication range of the case under 1 dBW-6 dBW noise overlaps with the case under 36 N·m-39.5 N·m torque. So it is impossible to judge the structure state with mere characterization indexes. Evaluation index T can extract the correlation difference of the conductance spectrum under the noise conditions and looseness conditions with the benchmark respectively. And there are different indication ranges of T on the noise and minor looseness. By determining a threshold and comparing T with it, whether bolt looseness occurs in an unknown condition can be effectively judged. Finally, T is applied to other flange structure with 8 bolts to verify the effectiveness and general applicability of the method. The evaluation index plays an important role in avoiding misjudgment of flange bolt caused by noise influence on minor looseness and improving the ability of identification when the bolt is at the critical state.
Piezoelectric sensor is a crucial part of electromechanical impedance technology whose state will directly affect the effectiveness and accuracy of structural health monitoring (SHM). So carrying out sensor self‐diagnosis is important and necessary. However, it is still difficult to distinguish sensor faults from structural damage as well as identify the cases and degrees of sensor faults. In the study, three characteristic indexes of admittance which have different indication intervals for damages of structure and sensors were selected from six indexes after comparison. To improve the discrimination effect, three principal components (PC) were extracted by principal component analysis (PCA). And the damage information represented by PCs was clustered by the K‐means algorithm to identify the cases of damage. Then, the degrees of sensor damages were classified with the artificial neural network (ANN). The results show that the K‐means clustering analysis based on admittance characteristics can accurately distinguish and identify the structural damage and four kinds of sensor damages, namely, pseudosoldering, debonding, wear, and breakage. The trained ANN model has a good recognition effect on the damage degrees and the accuracy of recognition reaches 100%. This study has a certain reference value for piezoelectric sensor self‐fault identification.
1 January 2024 in Structural Control and Health Monitoring
The multiple intersecting stiffeners on the chemical milling stiffened panel (CMSP) limit the application of active health monitoring methods on it. An imaging algorithm based on electromechanical impedance (EMI) and probability‐weighting is proposed to achieve quantitative evaluation and localization of the damage on CMSP. The proposed algorithm compensates for the difference in sensor performance with coefficients and there is no need to determine the key parameters of the algorithm through prior experiments. In the paper, the applicability of ultrasonic guided wave (GW) and EMI on CMSP was first studied through the finite element method. Based on EMI and the mean absolute percentage deviation (MAPD), the selected damage indicator (DI), a probability‐weighted damage imaging algorithm are proposed and experimentally verified. The results indicate that due to the reflection and attenuation effects of stiffeners on GW, the signal characteristics of damage scattering waves are contaminated, making it difficult to quantitatively characterize the damage from GW signals through DIs. MAPD is positively correlated with the damage degree and has consistency in characterizing the signal of different PZTs under the same working condition. The feasibility and accuracy of the proposed algorithm are verified through experiments which show a strong engineering application capability.
8 May 2024 in IEEE Transactions on Instrumentation and Measurement
Mode conversion and wave scattering will occur when ultrasonic guided wave (GW) propagates to the stiffener which makes the received signals complex and poorly interpretable, thus limiting the application of GW in damage detection of chemical milling stiffened panel (CMSP). This article proposes a deep learning (DL) model inception-convolutional neural network (Inception-CNN) to realize damage localization of CMSP. First, a model analysis was conducted to get the resonant frequency of the piezoelectric wafer, and the mode conversion at the stiffener was explored through numerical analysis. Then, the identification effect based on the conventional damage imaging method was discussed. Finally, for training the proposed DL model, the residual signals were collected as a dataset after setting damages in different zones of CMSP. The model was then trained and tested, and its performance was analyzed and demonstrated. The results indicate that S0 mode has a greater conversion degree than A0 mode at the stiffener; GWs do not propagate in the form of a uniform wavefront on CMSP and conventional damage imaging methods based on the wave propagation paths are not applicable to CMSP. The model proposed can automatically extract the signal spatial features, accurately identify the corresponding damage zone, and its accuracy reaches 94% in the testing set. As the input features increase, the classification ability of the model will be further improved. The noise interference experiment shows that the model has good noise resistance performance at noise levels below 15%, indicating the feasibility of the model for practical applications.
In the electromechanical impedance-based health monitoring of structures, partial failure of piezoelectric lead zirconate titanate will result in signal changes, which may cause misjudgment of the structure state. Therefore, this paper proposes an evaluation method of the sensor condition based on k-nearest neighbors (kNNs) and least-squares regression (LSR) to make monitoring more reliable. After the analysis of the signal characteristics of three structural changes and four sensor faults, the principal components (PCs) of three indices are extracted by principal component analysis. Next, the kNN classifier is trained with the data represented by PCs and then tested by tenfold cross-validation. To determine the degree of sensor faults, LSR is used to fit the damage degree laws with multivariate nonlinear equations. The results show that the kNN model trained with three PCs has higher classification accuracy than the one trained with two PCs. The accuracy of the former reaches 100%. The R2 values of damage degree regressions of four sensor faults are all greater than 0.85, and the p-values are far less than 0.05, which denotes the effectiveness of the regression in the prediction of damage degree. This method has great application potential in evaluating sensor conditions accurately and quickly.
The shear horizontal (SH) wave in thin-walled structures has great potential in structural health monitoring since only a single SH0 mode exists when the excitation frequency is lower than the cut-off frequency of SH1 and SH0 is non-dispersive. Thickness-poled d15 lead zirconate titanate (PZT) ring-based omnidirectional SH wave piezoelectric transducers (OSH-PTs) have been proven to excite SH waves in the structure through the bonding layer. However, the analysis of interfacial shear stress in OSH-PT-bonding layer-structure (OBS) remains a critical and challenging issue. To this end, this paper first conducts static analysis on OSH-PT and the structure in a cylindrical coordinate system, then combines the stress–strain relationship in the bonding layer to obtain the differential equation for interfacial shear stress. Since the equation does not have a closed-form solution, a three-dimensional model of OBS was further established, and finite element analysis was conducted to obtain the variation law of shear stress distribution under different parameters of the bonding layer and OSH-PT. The results indicate that to generate greater maximum interfacial shear stress thus bettering SH wave excitation, the OSH-PT selected should have a smaller inner diameter and a larger ratio of outer diameter to inner diameter. Besides, the thickness and shear modulus of the actuator should also be greater. The bonding layer should be as thin as possible while having a larger shear modulus. The result of the paper can provide guidance for the OSH-PT design and optimization.