Qiang MIAO

Prof. Dr. Qiang MIAO

Nanjing University of Aeronautics and Astronautics (NUAA)

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Ceramics International
Verified
Journal Article
Closed access
MYMengjuan Yin
Mengjuan Yin
WLWenping Liang
Wenping Liang
QMQiang MIAO
Qiang MIAO
HYHaiyang Yu
Haiyang Yu

1 October 2021 in Ceramics International
Verified
Journal Article
Closed access
YLYangyang Liu
Yangyang Liu
QMQiang MIAO
Qiang MIAO
WLWenping Liang
Wenping Liang
HLHao Lin
Hao Lin
HMHanchun Ma
Hanchun Ma
XXXiao Xu
Xiao Xu

4 July 2023 in Metals and Materials International
Verified
Journal Article
Closed access
PDF file
YSYuanyuan Sun
Yuanyuan Sun
QMQiang MIAO
Qiang MIAO
WLWenping Liang
Wenping Liang
KZKai Zang
Kai Zang
YWYuting Wu
Yuting Wu
YSYindong Song
Yindong Song

1 January 2016 in Archives of Pathology & Laboratory Medicine
Verified
Journal Article
Open access
HHHua-Lan Huang
Hua-Lan Huang
SZShuai Zhu
Shuai Zhu
WWWeiqing Wang
Weiqing Wang
XNXin Nie
Xin Nie
YSYing-Ying Shi
Ying-Ying Shi
GLGui-Xing Li
Gui-Xing Li
Context: Cardiac troponins have become the gold standard for diagnosing acute myocardial infarction (AMI) in the general population; however, their diagnostic accuracy for hemodialysis (HD) patients presenting with chest pain or dyspnea is uncertain. Objective: To examine the diagnostic accuracy of high-sensitivity cardiac troponin T (hs-cTnT) assay for AMI in HD patients. Design: In this prospective study, we enrolled 670 consecutive stable HD patients presenting with chest pain or dyspnea on routine predialysis therapy in the nephrology department. Receiver operating characteristic (ROC) curves were used to examine the diagnostic accuracy of hs-cTnT levels at enrollment in HD patients presenting with chest pain or dyspnea, and the dynamic change in these levels after 3 hours. Results: Acute myocardial infarction was the adjudicated final diagnosis in 12% of HD patients. Among patients with a final diagnosis other than AMI, 97% had a plasma hs-cTnT concentration above the 99th percentile. At the time of enrollment, the area under the ROC curve of hs-cTnT levels for diagnosis of AMI was 0.68 (95% confidence interval [CI], 0.62–0.74; P < .001) with a cutoff value of 107.7 ng/L; the relative change after 3 hours was 0.90 (95% CI, 0.82–0.96, P < .001) with a cutoff value of 24%, and the absolute change was 0.88 (95% CI, 0.82–0.94, P < .001) with a cutoff value of 32.6 ng/L. The prognostic value for 40-day mortality varied with the magnitude of elevation in hs-cTnT levels. Conclusions: Tracking the dynamic change in hs-cTnT levels during the short term significantly increased this measure's diagnostic accuracy for AMI in HD patients.

4 October 2023 in Ceramics International
Verified
Journal Article
Closed access
MZMeng Zhang
Meng Zhang
RLRuixiang Liu
Ruixiang Liu
QMQiang MIAO
Qiang MIAO
WLWenping Liang
Wenping Liang
HZHui Zhao
Hui Zhao
YSYingdong Song
Yingdong Song

26 August 2024 in Lubricants
Verified
Journal Article
Open access
PDF file
YQYan Qi
Yan Qi
JGJiumei Gao
Jiumei Gao
WLWenping Liang
Wenping Liang
QMQiang MIAO
Qiang MIAO
FJFeilong Jia
Feilong Jia
Hao LinHao Lin
Hao Lin
The microstructure, mechanical performance, and tribological properties of SiC ceramic coatings prepared via atmospheric plasma spraying (APS) and chemical vapor deposition (CVD) method were compared to provide good anti-wear protection for carbon/carbon composites. The surface morphology of the APS-SiC coating was characterized as having a porous structure, whilst the CVD-SiC coating presented with many pyramidal-shaped crystals constituting the surface. The APS-SiC coating consists of a dominating SiC phase and a small fraction of the Si phase, while the XRD pattern of the CVD-SiC coating mainly consists of the SiC phase. The dense crystalline microstructure of the CVD-SiC coating made it possess a higher hardness and Young’s modulus at 31.0 GPa and 275 GPa, respectively. The higher H/E and H3/E2 parameters of the CVD-SiC coating implied that it exhibited better plastic resistance, which is also beneficial for anti-wear properties. The scratch test reflected the critical loads of the spallation of the APS-SiC coating and CVD-SiC coating, which were evaluated to be 25.9 N and 36.4 N, respectively. In the tribological test, the friction coefficient of the APS-SiC coating showed obvious fluctuations at high load due to damage to the SiC coating. The wear mechanism of the APS-SiC coating was dominated by abrasive wear and fatigue wear, while CVD-SiC was mainly dominated by abrasive wear. The wear rate of the CVD-SiC coating was far below that of the APS-SiC coating, suggesting the better wear-resistance of the CVD-SiC coating.