The condition of heritage and historic timber constructions depends on how they are exploited. Numerous environmental factors degrade the physical and mechanical properties of timber and hence, affect the load-bearing capacity of constructions. As a result, frequent evaluations of their technical condition become necessary. Currently, modern technologies allow for extensive diagnostics of timber constructions using non-destructive and semi-destructive methods; yet, in contrast to classical laboratory tests, there is insufficient knowledge of the impact of individual factors on the results of such studies. This article presents an assessment of the influence of the moisture content of timber elements on the results of ultrasonic stress wave, sclerometric, and resistance drilling tests. Additionally, computed tomography scans were performed on selected samples to demonstrate the destruction mechanism occurring during the semi-destructive tests. The research involved three types of wood: pine, spruce, and fir of different moisture contents. The results reveal a strong relation between the moisture of timber and all the tests conducted in terms of both hygroscopic and capillary moisture.
In this paper, the issue of self-compacting concrete (SCC) with the addition of polyethylene terephthalate (PET) recycled aggregate is addressed. The PET utilized was a waste fraction in the PET-bottle-recycling process. The implementation of waste in concrete mixes has a positive impact on their environmental and social profile; however, technical requirements are not necessarily met. In this investigation, PET was used as a substitute for fine aggregate in quantities ranging from 0 to 20% in increments of 5%. Both the flow properties of SCC mixes and the hardened SCC properties (compressive strength, splitting tensile strength, modulus of elasticity, and Poisson ratio) were investigated. Additionally, non-destructive tests (ultrasound and sclerometric) were performed to determine the correlation curves. The research revealed that both the flow properties and the parameters of the hardened concrete deteriorated with the PET content. Concrete with 20% PET replacement did not meet the self-compacting requirements and its compressive strength decreased by almost 50%. However, it was noted that replacing fine aggregate with PET aggregate in the amount of 5% did not significantly alter the concrete parameters and could be an attractive alternative to traditional concretes. Based on non-destructive testing, correlation curves were constructed that could be applicable to the future quality assessment of self-compacting concretes with recycled PET aggregate.
Composite materials are increasingly used to strengthen existing structures or new load-bearing elements, also made of timber. In this paper, the effect of the number of layers of Carbon Fiber Reinforced Polymer (CFRP) on the load-bearing capacity and stiffness of Glued Laminated Timber beams was determined. Experimental research was performed on 32 elements—a series of eight unreinforced beams, and three series of eight reinforced beams: with one, three and five layers of laminate each. The beams with a cross-section of 38 mm × 80 mm and a length of 750 mm were subjected to the four-point bending test according to standard procedure. For each series, destructive force, deflection, mode of failure, and equivalent stiffness were determined. In addition, for the selected samples, X-ray computed tomography was performed before and after their destruction to define the quality of the interface between wood and composite. The results of the conducted tests and analyses showed that there was no clear relationship between the number of reinforcement layers and the load-bearing capacity of the beams and their stiffness. Unreinforced beams failed due to tension, while reinforced CFRP beams failed due to shear. Despite this, a higher energy of failure of composite-reinforced elements was demonstrated in relation to the reference beams.
Construction and demolition (C&D) waste management should be accordance with the waste management hierarchy. In practice, C&D waste are often downcycling. It is the result of many factors, including lack of awareness about the value inherent in waste. The paper presents analysis of the adaptability of non-destructive testing (NDT) methods for technical assessment of waste properties. As part of the work, non-destructive testing methods were described and classified in accordance with material and the features they enable testing. The publication presents examples of the use of NDT in the recovery of building materials during construction projects, in the field of influence of technical information of waste on the way it is managed. Finally, a scheme of waste management process during the renovation of an object with the application of NDT methods was presented.
The contribution of natural wood defects such as knots is an important factor influencing the strength characteristics of structural timber. This paper discusses the use of active thermography in the timber diagnostics, particularly in the determination of the knot area ratio (KAR) in elements covered with paint coatings. Moreover, on the basis of thermal images, the localization for the subsequent semi-destructive tests (SDTs) was established. Three different sources of external energy supply were used in the studies: laboratory dryer, air heater and halogen lamps. The active thermography tests were performed on elements made of three wood species (fir, pine and spruce). The specimens were covered with varying layers of paint coatings and primers, to reflect the actual condition of the historic structural elements. The obtained thermal images enabled the estimation of the KAR, due to the difference in temperature between solid wood and knots occurring therein. It should be noted that the results were affected by an external energy source and subjective judgement of the operator. Moreover, active thermography could be an effective method for the indication of the regions within which SDTs should be performed in order to properly assess the technical state of an element covered with polychrome.
Wood maintains remarkable durability under optimum conditions. However, it erodes faster than other construction materials in the circumstances of average usage of civil structures. Therefore, built features made of wood, especially historical features and structures, require repairs and reinforcements more frequently than those made of other materials. Non-destructive testing is usually carried out in structures that are currently in use and is aimed at early detection of failures and taking appropriate remedial measures. It can be generally assumed that diagnostic testing of wood is a difficult process due to its structure. However, the ability to identify the current strength parameters of wooden structural components makes it possible to properly assess their suitability for further use and design appropriate reinforcement and reconstruction methods. However, it should be noted that non-destructive test results are influenced by many factors such as: the type of wood, its defects, moisture content, age and the direction of test in relation to annual growth rings as well as microbial agents. This paper addresses the evaluation of the mechanical properties of pine wood under testing perpendicular, vertical and diagonal to the annual growth rings. Furthermore, the paper presents problems related to direction of test content on the results of non-destructive testing (sclerometer, ultrasonic tests and cutting resistance measurements). Based on the survey, it was found that the orientation of the test direction with respect to the annual growth rings must be taken into account in the course of the analysis using non-destructive methods