Milena Kucharska

Dr. Milena Kucharska

AGH Univeristy of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
Justyna Jaskowska-LemańskaJustyna Jaskowska-Lemańska
Justyna Jaskowska-Lemańska
MKMilena Kucharska
Milena Kucharska
JMJakub Kacper Matuszak
Jakub Kacper Matuszak
PNPaweł Nowak
Paweł Nowak
WŁWojciech Łukaszczyk
Wojciech Łukaszczyk
In this paper, the issue of self-compacting concrete (SCC) with the addition of polyethylene terephthalate (PET) recycled aggregate is addressed. The PET utilized was a waste fraction in the PET-bottle-recycling process. The implementation of waste in concrete mixes has a positive impact on their environmental and social profile; however, technical requirements are not necessarily met. In this investigation, PET was used as a substitute for fine aggregate in quantities ranging from 0 to 20% in increments of 5%. Both the flow properties of SCC mixes and the hardened SCC properties (compressive strength, splitting tensile strength, modulus of elasticity, and Poisson ratio) were investigated. Additionally, non-destructive tests (ultrasound and sclerometric) were performed to determine the correlation curves. The research revealed that both the flow properties and the parameters of the hardened concrete deteriorated with the PET content. Concrete with 20% PET replacement did not meet the self-compacting requirements and its compressive strength decreased by almost 50%. However, it was noted that replacing fine aggregate with PET aggregate in the amount of 5% did not significantly alter the concrete parameters and could be an attractive alternative to traditional concretes. Based on non-destructive testing, correlation curves were constructed that could be applicable to the future quality assessment of self-compacting concretes with recycled PET aggregate.

28 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
MKMilena Kucharska
Milena Kucharska
Justyna Jaskowska-LemańskaJustyna Jaskowska-Lemańska
Justyna Jaskowska-Lemańska
The contribution of natural wood defects such as knots is an important factor influencing the strength characteristics of structural timber. This paper discusses the use of active thermography in the timber diagnostics, particularly in the determination of the knot area ratio (KAR) in elements covered with paint coatings. Moreover, on the basis of thermal images, the localization for the subsequent semi-destructive tests (SDTs) was established. Three different sources of external energy supply were used in the studies: laboratory dryer, air heater and halogen lamps. The active thermography tests were performed on elements made of three wood species (fir, pine and spruce). The specimens were covered with varying layers of paint coatings and primers, to reflect the actual condition of the historic structural elements. The obtained thermal images enabled the estimation of the KAR, due to the difference in temperature between solid wood and knots occurring therein. It should be noted that the results were affected by an external energy source and subjective judgement of the operator. Moreover, active thermography could be an effective method for the indication of the regions within which SDTs should be performed in order to properly assess the technical state of an element covered with polychrome.

1 May 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
Piotr DybełPiotr Dybeł
Piotr Dybeł
MKMilena Kucharska
Milena Kucharska

20 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Piotr DybełPiotr Dybeł
Piotr Dybeł
MKMilena Kucharska
Milena Kucharska
The effect of different placing methods of the self-compacting concrete (SCC) mix—from the top and from the bottom of the form—on the bond failure mechanism was investigated within the scope of this paper. Existing studies regarding the known mechanisms of bond failure do not consider the bottom-up method of concrete placing, which improves the quality of the concrete microstructure around reinforcing bars. Background tests were performed on panel elements with dimensions of 800 × 480 × 160 mm. Ribbed steel reinforcing bars with a diameter of 16 mm were used in the tests, which were placed horizontally in the forms. A pull-out method was used to investigate the bond strength. X-ray computed tomography (CT) was used as a novel and non-destructive technique that allowed a 3D insight into the bond between the rebar and the concrete after the ultimate bond stress had been reached. The results provided a clear description of the phenomena occurring during the fresh state of concrete in the vicinity of rebars (bleeding, plastic settlement, vertical density variation) and showed their significance for bond mechanisms. Finally, it was demonstrated that placing the mix from the bottom of the form resulted in the same bond failure mechanism for both bars located at the top and the bottom of the panel elements. This was translated into identical bond properties throughout the element with regard to bond stiffness and bond strength. It was found that the described and known mechanisms of bond failure are only an idealized description of the performance of the reinforcing bar-concrete joint. The analysis of the steel–concrete interface (SCI) imaging indicated that, in reality, the forming bond failure mechanisms were a complex process that could be affected by many factors.

29 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
Piotr DybełPiotr Dybeł
Piotr Dybeł
MKMilena Kucharska
Milena Kucharska
In the study, experiments were performed on two eco-efficient self-compacting concrete mixes of reduced binder content containing supplementary cementitious materials. The behaviour of the eco-efficient self-compacting concrete (SCC) mixture was examined to determine whether it is suitable for multilayer casting. It is recommended that the SCC should be poured in an uninterrupted manner. However, it is not uncommon that contractors are forced to take breaks as a result of delivery delays. Casting the elements in multiple poorly prepared layers may cause the creation of cold joints between them. Two technological variants of the multilayer casting of eco-efficient SCC on beam elements were analysed: pouring the mixture from a minor height on the previously placed layer and placing the subsequent layer on the mechanically disturbed surface of the underlying material. Different delay times were used: 15, 30, 45 and 60 min between the execution of two layers of eco-efficient SCC. The load-bearing capacity of the joint was determined using a splitting tensile strength test on cubic elements. It was observed that, regardless of the mixture and casting variant, the interlayer bond strength decreased as the delay time increased. This effect was less pronounced when the first layer was mechanically disturbed. It was also demonstrated that concrete with reduced binder content is characterized by a lower drop in bond strength between successive layers. Finally, it is noted that the current recommendations and normative guidelines for the multilayer casting of self-compacting concrete should be specified with regard to the time delay allowed for the execution of the next layer in the absence of interference with the previously placed layer. Lack of clarity in this respect may result in the creation of a cold joint and hence a reduction in the load-bearing capacity between layers.

1 September 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
Piotr DybełPiotr Dybeł
Piotr Dybeł
MKMilena Kucharska
Milena Kucharska
Concrete is one of the most commonly used building materials in the world. Its production is increasing year by year, and is associated with harmful emissions of carbon dioxide (CO2) and particulates (PM10) into the environment, as well as the deterioration of natural resources. In accordance with the policy of sustainability, new technologies have being introduced into the civil engineering industry for several decades, for example new generation concrete. Depending on the specific application and innovation needs, they are characterised by different mechanical properties, structure, mix composition or behaviour in comparison to conventional concretes. These changes are intended, among other things, to minimize environmental impact during production, increase the durability and resistance to environmental hazards, prolong the reliability of the structure and reduce the life cycle costs of the structure. Examples of concretes belonging to the group of new generation concretes are above all: high performance concretes, self-compacting concretes, eco-efficient concretes, self-healing concretes. The paper presents a general outline of the issues related to the new generation concretes. The differences between each new generation concrete and conventional concrete are described. Possible applications of new generation concretes in civil engineering are presented. An attempt was made to determine the advantages and disadvantages of each of the discussed concretes.