Guowei Gao

Prof. Guowei Gao

Beijing Information Science and Technology University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JHJingfang Hu
Jingfang Hu
YLYueqi Li
Yueqi Li
GGGuowei Gao
Guowei Gao
SXShanhong Xia
Shanhong Xia
We have developed a novel mediated biochemical oxygen demand (BOD) biosensor based on immobilized Bacillus subtilis (B. subtilis) on three-dimensional (3D) porous graphene-polypyrrole (rGO-PPy) composite. The 3D porous rGO-PPy composite was prepared using hydrothermal method following with electropolymerization. Then the 3D porous rGO-PPy composite was used as a support for immobilizing negatively charged B. subtilis denoted as rGO-PPy-B through coordination and electrostatic interaction. Further, the prepared rGO-PPy-B was used as a microbial biofilm for establishing a mediated BOD biosensor with ferricyanide as an electronic acceptor. The indirect determination of BOD was performed by electrochemical measuring ferrocyanide generated from a reduced ferricyanide mediator using interdigited ultramicroelectrode array (IUDA) as the working electrode. The experimental results suggested a good linear relationship between the amperometric responses and BOD standard concentrations from 4 to 60 mg/L, with a limit detection of 1.8 mg/L (S/N ≥ 3). The electrochemical measurement of real water samples showed a good agreement with the conventional BOD5 method, and the good anti-interference as well as the long-term stability were well demonstrated, indicating that the proposed mediated BOD biosensor in this study holds a potential practical application of real water monitoring.

13 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JWjiyang wang wang
jiyang wang wang
JHJingfang Hu
Jingfang Hu
SHShiwei Hu
Shiwei Hu
GGGuowei Gao
Guowei Gao
YSYu Song
Yu Song
A novel electrochemical sensor based on electropolymerized ion imprinted poly (o-phenylenediamine) PoPD/electrochemical reduced graphene (ERGO) composite on glass carbon electrode (GCE) was fabricated for selective and sensitive determination of trace Cd(II) in water. ERGO was first deposited on the surface of GCE by electrochemical cyclic voltammetry (CV) scanning to enhance the electron transport activity at electrode surface. The ion imprinted polymer (IIP) of imprinted PoPD was then in situ electropolymerized on ERGO via CV scanning with oPD as functional monomer and Cd(II) ions as template, following removal of the template using electrochemical peroxidation method. The obtained imprinted PoPD/RERGO composites were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray energy spectroscopy (EDS) for the observation of their morphologies and components. The electrochemical behavior of the imprinted PoPD/ERGO/GCE was performed by CV and SWASV. The fabricated sensor of the imprinted PoPD/ERGO/GCE showed a good selectivity toward target Cd(II) ions in the presence of other heavy metal ions. Under the optimized experimental conditions, the sensor exhibited a good linear relationship between SWASV stripping peak values and Cd(II) concentration in the range of 1 to 50 ng/mL, with the limit of detection as 0.13 ng/mL (S/N = 3). The proposed electrochemical sensor of imprinted PoPD/ERGO/GCE was successfully applied for trace Cd(II) determination in real water samples.

13 September 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
GSGuangRun Sheng
GuangRun Sheng
GGGuowei Gao
Guowei Gao
BZBoyuan Zhang
Boyuan Zhang
The large random errors in Micro-Electro-Mechanical System (MEMS) gyros are one of the major factors that affect the precision of inertial navigation systems. Based on the indoor inertial navigation system, an improved wavelet threshold de-noising method was proposed and combined with a gradient radial basis function (RBF) neural network to better compensate errors. We analyzed the random errors in an MEMS gyroscope by using Allan variance, and introduced the traditional wavelet threshold methods. Then, we improved the methods and proposed a new threshold function. The new method can be used more effectively to detach white noise and drift error in the error model. Finally, the drift data was modeled and analyzed in combination with the RBF neural network. Experimental results indicate that the method is effective, and this is of great significance for improving the accuracy of indoor inertial navigation based on MEMS gyroscopes.

5 January 2021 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYansheng Li
Yansheng Li
XMXiujin Men
Xiujin Men
GGGuowei Gao
Guowei Gao
YTYe Tian
Ye Tian
YWYongqiang Wen
Yongqiang Wen
XZXueji Zhang
Xueji Zhang
A visual quantitative distance-based biosensor through capillary action is proposed, which converts the wettability changes caused by the target molecules into a capillary rise height signal without any manufacturing technology.

1 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LWLinzhe Wang
Linzhe Wang
JHJingfang Hu
Jingfang Hu
WWWENSONG WEI
WENSONG WEI
SXShuyu Xiao
Shuyu Xiao
JWjiyang wang wang
jiyang wang wang
LQLei Qin
Lei Qin
Three-dimensional (3D) porous graphene-based materials have displayed attractive electrochemical catalysis and sensing performances, benefiting from their high porosity, large surface area, and excellent electrical conductivity. In this work, a novel electrochemical sensor based on 3D porous reduced graphene (3DPrGO) and ion-imprinted polymer (IIP) was developed for trace cadmium ion (Cd(II)) detection in water. The 3DPrGO was synthesized in situ at a glassy carbon electrode (GCE) surface using a polystyrene (PS) colloidal crystal template and the electrodeposition method. Then, IIP film was further modified on the 3DPrGO by electropolymerization to make it suitable for detecting Cd(II). Attributable to the abundant nanopores and good electron transport of the 3DPrGO, as well as the specific recognition for Cd(II) of IIP, a sensitive determination of trace Cd(II) at PoPD-IIP/3DPrGO/GCE was achieved. The proposed sensor exhibited comprehensive linear Cd(II) responses ranging from 1 to 100 μg/L (R2 = 99.7%). The limit of detection (LOD) was 0.11 μg/L, about 30 times lower than the drinking water standard set by the World Health Organization (WHO). Moreover, PoPD-IIP/3DPrGO/GCE was applied for the detection of Cd(II) in actual water samples. The satisfying recoveries (97–99.6%) and relative standard deviations (RSD, 3.5–5.7%) make the proposed sensor a promising candidate for rapid and on-site water monitoring.

6 May 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YLYansheng Li
Yansheng Li
PCPeng Chen
Peng Chen
GGGuowei Gao
Guowei Gao
LQLei Qin
Lei Qin
HYHongjun Yang
Hongjun Yang
XZXueji Zhang
Xueji Zhang